SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7A-4 Heater and Ventilation: 
Repair Instructions
HVAC Unit ComponentsS7RS0B7106001
For manual type A/C, refer to “HVAC Unit Components 
in S

Page 941 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Heater and Ventilation:  7A-5
• Check for operation and current.a. Put blower motor (1) in a soft-jawed vise.
b. Connect battery to blower mo

Page 942 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7A-6 Heater and Ventilation: 
Blower Motor Relay InspectionS7RS0B7106007
1) Remove junction block assembly referring to “BCM (Included in Jun

Page 943 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Heater and Ventilation:  7A-7
HVAC Control Unit Removal and InstallationS7RS0B7106009
Removal1) Disconnect negative (–) cable at battery.
2)

Page 944 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7A-8 Heater and Ventilation: 
b. Move temperature control lever (1) and air flow control plate (2) fully to the arrow direction. c. Fix tempera

Page 946 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7A-10 Heater and Ventilation: 
Air Intake Control Actuator InspectionS7RS0B7106013
Check air intake control actuator as follows:1) Using servic

Page 947 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Heater and Ventilation:  7A-11
Side Ventilation Louver Removal and 
Installation
S7RS0B7106015
Driver side ventilation louver
Removal1) Disconn

Page 972 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7B-24 Air Conditioning System: Manual Type
HVAC Unit Removal and InstallationS7RS0B7216006
Removal1) Disconnect negative (–) cable from batte

Page 973 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Air Conditioning System: Manual Type 7B-25
Evaporator Thermistor (Evaporator 
Temperature Sensor) Removal and Installation
S7RS0B7216008
Remova

Page 974 of 1496

SUZUKI SWIFT 2008 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7B-26 Air Conditioning System: Manual Type
Expansion Valve Removal and InstallationS7RS0B7216010
Removal1) Recover refrigerant fr om the A/C sy