Oil DAEWOO MATIZ 2003 Service Manual PDF
Page 325 of 1184
ENGINE CONTROLS 1F–227
DAEWOO M-150 BL2
a Freeze Frame conditions (rpm, load, vehicle speed, temperature, etc.) that .are noted. This will isolate when
the DTC failed.
DTC P0480 – Low Speed Cooling Fan Relay Circuit Fault (WITHOUT A/C)
StepActionValue(s)YesNo
1
Perform an Euro On-Board Diagnostic (EOBD)
System Check.
Is the system check complete?
–
Go to Step 2
Go to
“On-Board
Diagnostic
System Check”
2
1. Turn the ignition switch to ON with the engine
OFF.
2. Install a scan tool.
3. Command the relay ON and OFF.
Does the relay turn ON and OFF when
commanded?
–
Go to Step 3Go to Step 5
3
1. Turn the ignition switch to LOCK.
2. Disconnect the engine control module (ECM)
connector.
3. Turn the ignition switch to ON.
4. Using a digital voltmeter(DVM), measure the
current in low speed relay control circuit, at
terminal 39 to ground for 2 minutes.
Does the amperage measure less than the specified
value?
0.75 amps
Go to
“Diagnostic
Aids”
Go to Step 4
4
1. Turn the ignition switch to LOCK.
2. Disconnect the relay.
3. Using a DVM, measure the resistance between
terminals 87 and 39 in the relay control circuit in
the ECM harness connector to ground.
Does the DVM display infinite resistance?
–
Go to Step 12Go to Step 10
5
1. Turn the ignition switch to LOCK.
2. Disconnect the relay.
3. Connect a test light between the relay coil
terminals 30 and 87 in the relay harness
connector.
4. Turn the Turn the ignition switch to ON.
5. Using the scan tool, command the relay ON and
OFF.
Does the test light turn ON and OFF with each
commanded?
–
Go to Step 8Go to Step 6
6
With the test light connected to ground, probe the
ignition feed circuit in the relay harness connector.
Does the test light illuminate?
–
Go to Step 7Go to Step 11
7
1. Turn the ignition switch to LOCK.
2. Reconnect the relay.
3. Disconnect the ECM connector containing the
relay control circuit.
4. Turn the Turn the ignition switch to ON.
5. With a fused jumper wire connected to ground,
probe the relay control circuit at terminal 39 in the
ECM harness connector.
Does the relay operate?
–
Go to Step 9Go to Step 10
8Check the connections at the relay.
Is a problem found and corrected?–Go to Step 14Go to Step 12
Page 328 of 1184
1F–230 ENGINE CONTROLS
DAEWOO M-150 BL2
MAA1F270
DIAGNOSTIC TROUBLE CODE (DTC) – P0480 LOW SPEED COOLING FAN
RELAY CIRCUIT FAULT (WITH A/C)
Circuit Description
Ignition voltage is supplied directly to the cooling fan
relay coil. The engine control module(ECM) controls the
relay by grounding the control circuit via an internal
switch called a driver. The primary function of the driver
is supply the ground for the component being controlled.
Each driver has a fault line which is monitored by the
ECM. When the ECM is commanding a component ON,
the voltage of the control circuit should be low (near
0volts). When the ECM is commanding the control cir-
cuit to a component OFF, the voltage potential of the cir-
cuit should be high(near battery voltage). If the fault
detection circuit senses a voltage other than what is ex-
pected, the fault line status will change causing the DTC
to set.
The relay is used to control the high current flow to the
cooling fan motors. This allows the ECM driver to only
have to handle the relatively low current used by the
relay.
Conditions for Setting the DTC
Diagnostic Trouble Codes (DTCs) P0117, P0118 not
set.
Ignition ON.Ignition voltage is greater than 10 volts.
Engine run time is greater than 5 seconds.
Action Taken When The DTCs Sets
The Malfunction Indicator Lamp (MIL) will not illumi-
nate.
The ECM will store conditions which were present
when the DTC was set as Failure Records data only.
This information will not be stored in the Freeze
Frame data.
Conditions for Clearing the MIL/DTC
A history DTC will clear after 40 consecutive warm-up
cycles without a fault.
DTC(s) can be cleared by using the scan tool.
Diagnostic Aids
Using Freeze Frame and/or failure records data may aid
in locating an intermittent condition. If the DTC cannot
be duplicated, the information included in the Freeze
Frame and/or failure records data can be useful in deter-
mining how many miles since the DTC set. The fail
counter and Pass Counter can also be used to deter-
mine how many ignition cycles the diagnostics reported
Page 329 of 1184
ENGINE CONTROLS 1F–231
DAEWOO M-150 BL2
a Freeze Frame conditions (rpm, load, vehicle speed, temperature, etc.) that .are noted. This will isolate when
the DTC failed.
DTC P0480 – Low Speed Cooling Fan Relay Circuit Fault (with A/C)
StepActionValue(s)YesNo
1
Perform an Euro On-Board Diagnostic (EOBD)
System Check.
Is the system check complete?
–
Go to Step 2
Go to
“On-Board
Diagnostic
System Check”
2
1. Turn the ignition switch to ON with the engine
OFF.
2. Install a scan tool.
3. Command the relay ON and OFF.
Does the relay turn ON and OFF when
commanded?
–
Go to Step 3Go to Step 5
3
1. Turn the ignition switch to LOCK.
2. Disconnect the engine control module (ECM)
connector.
3. Turn the ignition switch to ON.
4. Using a digital voltmeter(DVM), measure the
current in low speed relay control circuit, at
terminal 10 to ground for 2 minutes.
Does the amperage measure less than the specified
value?
0.75 amps
Go to
“Diagnostic
Aids”
Go to Step 4
4
1. Turn the ignition switch to LOCK.
2. Disconnect the relay.
3. Using a DVM, measure the resistance between
terminals 85 and 5 in the relay control circuit in
the ECM harness connector to ground.
Does the DVM display infinite resistance?
–
Go to Step 12Go to Step 10
5
1. Turn the ignition switch to LOCK.
2. Disconnect the relay.
3. Connect a test light between the relay coil
terminals 86 and 85 in the relay harness
connector.
4. Turn the Turn the ignition switch to ON.
5. Using the scan tool, command the relay ON and
OFF.
Does the test light turn ON and OFF with each
commanded?
–
Go to Step 8Go to Step 6
6
With the test light connected to ground, probe the
ignition feed circuit in the relay harness connector.
Does the test light illuminate?
–
Go to Step 7Go to Step 11
7
1. Turn the ignition switch to LOCK.
2. Reconnect the relay.
3. Disconnect the ECM connector containing the
relay control circuit.
4. Turn the Turn the ignition switch to ON.
5. With a fused jumper wire connected to ground,
probe the relay control circuit at terminal 5 in the
ECM harness connector.
Does the relay operate?
–
Go to Step 9Go to Step 10
8Check the connections at the relay.
Is a problem found and corrected?–Go to Step 14Go to Step 12
Page 332 of 1184
1F–234 ENGINE CONTROLS
DAEWOO M-150 BL2
MAA1F090
DIAGNOSTIC TROUBLE CODE (DTC) – P0481 HIGH SPEED COOLING FAN
RELAY CIRCUIT FAULT (WITHOUT A/C)
Circuit Description
Ignition voltage is supplied directly to the cooling fan
relay coil. The engine control module(ECM) controls the
relay by grounding the control circuit via an internal
switch called a driver. The primary function of the driver
is supply the ground for the component being controlled.
Each driver has a fault line which is monitored by the
ECM. When the ECM is commanding a component ON,
the voltage of the control circuit should be low (near
0volts). When the ECM is commanding the control cir-
cuit to a component OFF, the voltage potential of the cir-
cuit should be high(near battery voltage). If the fault
detection circuit senses a voltage other than what is ex-
pected, the fault line status will change causing the DTC
to set.
The relay is used to control the high current flow to the
cooling fan motors. This allows the ECM driver to only
have to handle the relatively low current used by the
relay.
Conditions for Setting the DTC
Diagnostic Trouble Codes (DTCs) P0117, P0118 not
set.
Ignition ON.Ignition voltage is greater than 10 volts.
Engine run time is greater than 5 seconds.
Action Taken When The DTCs Sets
The Malfunction Indicator Lamp (MIL) will not illumi-
nate.
The ECM will store conditions which were present
when the DTC was set as Failure Records data only.
This information will not be stored in the Freeze
Frame data.
Conditions for Clearing the MIL/DTC
A history DTC will clear after 40 consecutive warm-up
cycles without a fault.
DTC(s) can be cleared by using the scan tool.
Diagnostic Aids
Using Freeze Frame and/or failure records data may aid
in locating an intermittent condition. If the DTC cannot
be duplicated, the information included in the Freeze
Frame and/or failure records data can be useful in deter-
mining how many miles since the DTC set. The fail
counter and Pass Counter can also be used to deter-
mine how many ignition cycles the diagnostics reported
Page 333 of 1184
ENGINE CONTROLS 1F–235
DAEWOO M-150 BL2
a Freeze Frame conditions (rpm, load, vehicle speed, temperature, etc.) that .are noted. This will isolate when
the DTC failed.
DTC P0481 – High Speed Cooling Fan Relay Circuit Fault (without A/C)
StepActionValue(s)YesNo
1
Perform an Euro On-Board Diagnostic (EOBD)
System Check.
Is the system check complete?
–
Go to Step 2
Go to
“On-Board
Diagnostic
System Check”
2
1. Turn the ignition switch to ON with the engine
OFF.
2. Install a scan tool.
3. Command the relay ON and OFF.
Does the relay turn ON and OFF when
commanded?
–
Go to Step 3Go to Step 5
3
1. Turn the ignition switch to LOCK.
2. Disconnect the engine control module (ECM)
connector.
3. Turn the ignition switch to ON.
4. Using a digital voltmeter(DVM), measure the
current in high speed relay control circuit, at
terminal 5 to ground for 2 minutes.
Does the amperage measure less than the specified
value?
0.75 amps
Go to
“Diagnostic
Aids”
Go to Step 4
4
1. Turn the ignition switch to LOCK.
2. Disconnect the relay.
3. Using a DVM, measure the resistance between
terminals 85 and 5 in the relay control circuit in
the ECM harness connector to ground.
Does the DVM display infinite resistance?
–
Go to Step 12Go to Step 10
5
1. Turn the ignition switch to LOCK.
2. Disconnect the relay.
3. Connect a test light between the relay coil
terminals 86 and 85 in the relay harness
connector.
4. Turn the Turn the ignition switch to ON.
5. Using the scan tool, command the relay ON and
OFF.
Does the test light turn ON and OFF with each
commanded?
–
Go to Step 8Go to Step 6
6
With the test light connected to ground, probe the
ignition feed circuit in the relay harness connector.
Does the test light illuminate?
–
Go to Step 7Go to Step 11
7
1. Turn the ignition switch to LOCK.
2. Reconnect the relay.
3. Disconnect the ECM connector containing the
relay control circuit.
4. Turn the Turn the ignition switch to ON.
5. With a fused jumper wire connected to ground,
probe the relay control circuit at terminal 5 in the
ECM harness connector.
Does the relay operate?
–
Go to Step 9Go to Step 10
8Check the connections at the relay.
Is a problem found and corrected?–Go to Step 14Go to Step 12
Page 336 of 1184
1F–238 ENGINE CONTROLS
DAEWOO M-150 BL2
MAA1F270
DIAGNOSTIC TROUBLE CODE (DTC) – P0481 HIGH SPEED COOLING FAN
RELAY CIRCUIT FAULT (WITH A/C)
Circuit Description
Ignition voltage is supplied directly to the cooling fan
relay coil. The engine control module(ECM) controls the
relay by grounding the control circuit via an internal
switch called a driver. The primary function of the driver
is supply the ground for the component being controlled.
Each driver has a fault line which is monitored by the
ECM. When the ECM is commanding a component ON,
the voltage of the control circuit should be low (near
0volts). When the ECM is commanding the control cir-
cuit to a component OFF, the voltage potential of the cir-
cuit should be high(near battery voltage). If the fault
detection circuit senses a voltage other than what is ex-
pected, the fault line status will change causing the DTC
to set.
The relay is used to control the high current flow to the
cooling fan motors. This allows the ECM driver to only
have to handle the relatively low current used by the
relay.
Conditions for Setting the DTC
Diagnostic Trouble Codes (DTCs) P0117, P0118 not
set.
Ignition ON.Ignition voltage is greater than 10 volts.
Engine run time is greater than 5 seconds.
Action Taken When The DTCs Sets
The Malfunction Indicator Lamp (MIL) will not illumi-
nate.
The ECM will store conditions which were present
when the DTC was set as Failure Records data only.
This information will not be stored in the Freeze
Frame data.
Conditions for Clearing the MIL/DTC
A history DTC will clear after 40 consecutive warm-up
cycles without a fault.
DTC(s) can be cleared by using the scan tool.
Diagnostic Aids
Using Freeze Frame and/or failure records data may aid
in locating an intermittent condition. If the DTC cannot
be duplicated, the information included in the Freeze
Frame and/or failure records data can be useful in deter-
mining how many miles since the DTC set. The fail
counter and Pass Counter can also be used to deter-
mine how many ignition cycles the diagnostics reported
Page 337 of 1184
ENGINE CONTROLS 1F–239
DAEWOO M-150 BL2
a Freeze Frame conditions (rpm, load, vehicle speed, temperature, etc.) that .are noted. This will isolate when
the DTC failed.
DTC P0481 – High Speed Cooling Fan Relay Circuit Fault (with A/C)
StepActionValue(s)YesNo
1
Perform an Euro On-Board Diagnostic (EOBD)
System Check.
Is the system check complete?
–
Go to Step 2
Go to
“On-Board
Diagnostic
System Check”
2
1. Turn the ignition switch to ON with the engine
OFF.
2. Install a scan tool.
3. Command the relay ON and OFF.
Does the relay turn ON and OFF when
commanded?
–
Go to Step 3Go to Step 5
3
1. Turn the ignition switch to LOCK.
2. Disconnect the engine control module (ECM)
connector.
3. Turn the ignition switch to ON.
4. Using a digital voltmeter(DVM), measure the
current in high speed relay control circuit, at
terminal 39 to ground for 2 minutes.
Does the amperage measure less than the specified
value?
0.75 amps
Go to
“Diagnostic
Aids”
Go to Step 4
4
1. Turn the ignition switch to LOCK.
2. Disconnect the relay.
3. Using a DVM, measure the resistance between
terminals 85 and 39 in the high speed cooling fan
relay control circuit in the ECM harness connector
to ground.
Does the DVM display infinite resistance?
–
Go to Step 12Go to Step 10
5
1. Turn the ignition switch to LOCK.
2. Disconnect the relay.
3. Connect a test light between the relay coil
terminals 86 and 85 in the relay harness
connector.
4. Turn the Turn the ignition switch to ON.
5. Using the scan tool, command the relay ON and
OFF.
Does the test light turn ON and OFF with each
commanded?
–
Go to Step 8Go to Step 6
6
With the test light connected to ground, probe the
ignition feed circuit in the relay harness connector.
Does the test light illuminate?
–
Go to Step 7Go to Step 11
7
1. Turn the ignition switch to LOCK.
2. Reconnect the relay.
3. Disconnect the ECM connector containing the
relay control circuit.
4. Turn the Turn the ignition switch to ON.
5. With a fused jumper wire connected to ground,
probe the relay control circuit at terminal 10 in the
ECM harness connector.
Does the relay operate?
–
Go to Step 9Go to Step 10
Page 345 of 1184
ENGINE CONTROLS 1F–247
DAEWOO M-150 BL2
Excessive engine overloading. Check for seized pul-
leys, pumps, or motors on the accessory drive,Overweight engine oil.
DTC P0505 Idle Air Control Valve (IACV) Circuit Fault
StepActionValue(s)YesNo
1
Perform an On-Board Diagnostic (EOBD) System
Check.
Was the check performed?
–
Go to Step 2
Go to
“On-Board
Diagnostic
System Check”
2
1. Install a scan tool to the Data Link Connector
(DLC).
2. Operate the engine to idle speed.
3. Transmission in park or neutral and the parking
brake set.
4. A/C is off.
5. Using scan tool, command the Idle Air Control
(IAC) valve up and down between the specified
value.
Does the rpm change smoothly when he
commanded by the scan tool?
900–1200
rpm
Go to Step 3Go to Step 5
3
1. Turn the ignition OFF.
2. Disconnect the IAC valve connector.
3. Measure the resistance between terminal C and
D of the IAC valve.
4. Measure the resistance between terminal B and A
of the IAC valve.
Is the resistance within the specified value?
40–80 ΩGo to Step 4Go to Step 13
4
1. Measure the resistance between terminal D and
B of the IAC valve.
2. Measure the resistance between terminal C and
A of the IAC valve.
Is the resistance equal to the specified value?
∞Go to Step 15Go to Step 13
5
1. Turn the ignition OFF.
2. Disconnect the IAC valve connector.
3. Turn the ignition ON.
4. With test light connected to ground, probe the
IAC connector terminals.
Does the test light illuminate on D terminals?
–
Go to Step 6Go to Step 7
6
With test light connected to B+, probe the IAC
connector terminals.
Does the test light illuminate on D terminals?
–
Go to Step 8Go to Step 9
7
Check for an open or short to ground in the IAC high
and low circuits and repair as needed.
Is the repair complete?
–
Go to Step 15Go to Step 10
8
1. Idle the engine.
2. Connect a test light to ground, probe the IAC
connector terminals.
Does the test light flash On and OFF for all
terminals?
–
Go to Step 11Go to Step 12
9
Check for an open or a short to voltage in the IAC
valve high and low circuits and repair as needed.
Is the repair complete?
–
Go to Step 15Go to Step 10
10
Check the Engine control Module (ECM) connector
for poor connections and repair as needed.
Is the repair complete?
–
Go to Step 15Go to Step 14
Page 368 of 1184
1F–270 ENGINE CONTROLS
DAEWOO M-150 BL2
MAA1F330
DIAGNOSTIC TROUBLE CODE (DTC) – P1628 IMMOBILIZER NO SUCCESSFUL
COMMUNICATION
Circuit Description
When the ignition switch is turned to ON, the key tested
by immobilizer anti-theft system. While the key code is
being read by immobilizer control unit or integrated anti-
theft control unit, the engine can start run with any key
that will turn the lock cylinder. the key code is read and
compared with key codes that have been stored in the
memory of the immobilizer control unit. If a valid key is
detected, the immobilizer control unit sends a serial data
release message to the Engine Control Module (ECM).
Included in the release message is an identification (ID)
code which assures that neither the immobilizer control
unit nor the ECM have been substituted to defeat the
system. If the ECM receives an invalid release mes-
sage, the ECM performs the following action:
Disable the fuel injector circuit.
Disable the fuel pump circuit.
Disable the ignition coil.
A Diagnostic Trouble Code (DTC) will stored if detect
communication link failure between the ECM and im-
mobilizer control unit.Conditions for Setting the DTC
Ignition switch is turned to ON.
Immobilizer option auto detected.
ECM release time window(1.5 or 2 seconds) expired.
Vehicle Speed Sensor (VSS) signal is less than 512
km/h.
Action Taken When the DTC Sets
The Malfunction Indicator Lamp (MIL) will not illumi-
nate.
The ECM will store conditions which were present
when the DTC was set as Failure Records data only.
This information will not be stored in the Freeze
Frame data.
Conditions for Clearing the MIL/DTC
A history DTC will clear after 40 consecutive warm-up
cycles without a fault.
DTC(s) can be cleared by using the scan tool.
Page 370 of 1184
1F–272 ENGINE CONTROLS
DAEWOO M-150 BL2
MAA1F330
DIAGNOSTIC TROUBLE CODE (DTC) – P1629 IMMOBILIZER WRONG
COMPUTATION
Circuit Description
When the ignition switch is turned to ON, the key tested
by immobilizer anti-theft system. While the key code is
being read by immobilizer control unit or integrated anti-
theft control unit, the engine can start run with any key
that will turn the lock cylinder. the key code is read and
compared with key codes that have been stored in the
memory of the immobilizer control unit. If a valid key is
detected, the immobilizer control unit sends a serial data
release message to the Engine Control Module (ECM).
Included in the release message is an identification (ID)
code which assures that neither the immobilizer control
unit nor the ECM have been substituted to defeat the
system. If the ECM receives an invalid release mes-
sage, the ECM performs the following action:
Disable the fuel injector circuit.
Disable the fuel pump circuit.
Disable the ignition coil.
A Diagnostic Trouble Code (DTC) will stored if detect
communication link failure between the ECM and immo-
bilizer control unit.Conditions for Setting the DTC
Ignition switch is turned to ON.
Immobilizer option auto detected.
ECM release time window(1.5 or 2 seconds) expired.
Vehicle Speed Sensor (VSS) signal is less than 512
km/h.
Action Taken When the DTC Sets
The Malfunction Indicator Lamp (MIL) will not illumi-
nate.
The ECM will store conditions which were present
when the DTC was set as Failure Records data only.
This information will not be stored in the Freeze
Frame data.
Conditions for Clearing the MIL/DTC
A history DTC will clear after 40 consecutive warm-up
cycles without a fault.
DTC(s) can be cleared by using the scan tool.