GREAT WALL HOVER 2006 Service Repair Manual
Page 381 of 425
Safety airbag-11
2. Normal-light of safety airbag system indicator lamp
2 Normal-light of safety airbag system alarm lamp
Test status Normal-light of safety airbag system alarm lamp
Possible causes Insufficient battery voltage
ECU internal failure
Combined instrument safety airbag alarm lamp failure
ECU plug misconnects
Combined instrument plug bad-contact
ECU power-supply fuse shutoff or bad contact
Misconnection of ECU plug terminal
Bad contact between ECU plug terminal and grounding wiring
harness.
Driver ’s or passengers’ side safety airbag circuit failure.
Procedure Te s t Operation
Yes Next procedure.
3 Test the wiring harness connection between ECU
unit and instrument cluster.
·Place the ignition switch in LOCK position。
·shut off accumulator negative line
·shut off the instrument cluster plug
·test the connection b etween alarm lamp circuit
and its relative circuits No Replace the wiring harness and get into
step 5
Page 382 of 425
Safety airbag-12
Begin the test with diagnostic communication with special diagnostic device (X-431 diagnostic tester) and ECU
to find out the failure causes, do the next test providing communication is not successful.
Procedure Te s t Operation
Yes Next procedure
1 Test the battery
Test the battery voltage
Is the voltage higher 9V? No Insufficient battery supply.
Test the charging/discharging
system, then go to step 5.
Yes Next step
2 Test the wiring harness connection between ECU and
combined instrument.
Place the ignition switch in LO C K position。
Shut off the battery negative.
O pen the central channel guard plate.
Shut off the instrument combined connector clip
Connect the negative of battery
Place the ignition switch in ON position.
Check whether the instrument connector clip terminal
voltage is 12V(power supply and instrument line) No Check the circuit and continue the
operation according to step 5.
Yes Next step
3 Place the ignition switch in LO C K position。
Check the connection of corresponding terminals between
instrument connector clip and diagnostic interface
(diagnose the two ends of K-line) No Repair or replace the wiring
harness and continue according to
step 5
Yes Next step
3 Make sure the shutoff of accumulator negative line and
keep the status for at least 1 minute.
Shut off ECU connector clip
Shut off the instrument cluster plug.
Connect the ECU plug terminal 5,7,9 and instrument
cluster plug? No Replace the wiring harness and
step 5
Yes Replace ECU
4 Remove EC U to check the condition of term inal and
whether the shorting bar is broken.
No Reconnect EC U connector clip
and next step.
Yes Troubleshooting followed by the
explanations to customers upon
the repair ing pro ced ur e.
5
Make sure that the failure will never reoccur after
repairing.
Place the ignition switch in LO C K position。
Shut off accumulator negative line and keep the status for
at least 1 m in ute.
Connect all ECU plugs
Connect the driver’s side safety airbag combined
instrum ent p lug
Connect the passengers’ side safety airbag combined
instrum ent p lug
Connect the driver and passengers’ side pretension safety
belts plugs.
(Vehicles with pretension safety-b elts)
Connect clock spring plug
Connect the accumulator negative line
Place the ignition switch in ON position
Does the safety airbag alarm lamp work functionally? No Retest the failure symptoms;
repeat from step 1 if the failure
reoccurs.
Page 383 of 425
Safety airbag-13
Internal failure
Failure code
$9071 SRS safety airbag system unit internal failure
Test condition Warning
The test condition of this failure is the failure code that may not emerge before the test,
DTC conducts the test, and the preparatory work must be done before the test because the
damage to working personnel or system may be caused by the incorrect operation during the
test.
SRS safety airbag system electronic-control unit internal circuit failure.
Possible causes SRS safety airbag system unit internal failure
Operation
With regard to replacing SRS safet y airbag system unit, take references in the removal/installation of safety airbag system
Page 384 of 425
Safety airbag-14
Power-supply
Failure code
$9032 Low power-supply voltage for SRS safety airbag system electronic-control unit
Test condition Warning
The test condition of this failure is the failure code that may not emerge before the test, DTC conducts the test,
and the preparatory work must be done before the test because the damage to working personnel or system
may be caused by the incorrect op eration during the test.
The voltage for SRS safety airbag system unit connector clip is stitch 5 and 6 is under 9V
Possible
caus es Accumulator low voltage
Failure with the wiring harness between accumulator and SRS safety airbag system electronic-control unit
Procedure Test Operation
Yes Next step
1 Check accumulator
Test accumulator voltage
Is the voltage above 9V No Accumulator low voltage, test the
recharging/discharging system
Yes Next step
2 Check the wiring harness between accumulator and fuse
panel
Remove fuse panel without releasing the connector clips
Place the ignition switch in ON position
Test the potential of two fuse corresponding contactors, the
potential above 9V? No Check the wiring harness
Yes Next step
3 Check the wiring harness between fuse panel and SRS
safety airbag system unit connector clip
Warning:
If not correctly handled, the safety airbag module as well
as pretension safety belt may possibly be trigged, released
and tensioned, thus make serene damage to people.
Ther efor e, pleas e carefully r ead the r epairing warning
before trouble handling. Please take references in safety
airbag system repairing warning
Place the ignition switch in LOCK position
Release accumulator negative wire and wait for 1 minute
plus
Remove steering pillar shell
Release the clock spring connection clips
Remove the PAB trim cover, glove box (passengers’ side
safety airbag is under the trim cover)
Release passengers’ side safety airbag module connector
clips
Release all SRS safety airbag system unit connector clips
Install back the accumulator negative wire,
Place the ignition switch in ON position
Is the potential of SRS safety airbag system unit connector
clips stitch 5,6(grounding) above 9V? No Replace wiring harness
Page 385 of 425
Safety airbag-15
Yes Present failure codes
Replace SRS safety airbag system unit
See he removal/installation of SRS
safety airbag system unit
History accumulated failure codes
The end of failure diagnosis
4 Place the ignition switch in LOCK position
Release accumulator negative wire and wait for 1 minute
plus
Remove the left trim cover
Shut off SRS safety airbag system unit translation
connector clips
Install back the accumulator negative wire, place the
ignition switch in ON position
Is the potential of SRS safety airbag system unit connector
clips stitch 5,6(grounding) above 9V? No Replace wiring harness
Drive side failure
Failure code
$9021
$9022
$9024
$9025 Driver ’s side safety airbag failure (high or low resistance, shorting grounding, etc.)
Tes t
condition Warni ng
If not correctly handled, the safety airbag module as well as pretension safety belt may possibly be trigged, released
and tensioned, thus make serene damage to people. Therefore, please carefully read the repairing warning before
trouble handling. Please take references in safety airbag system repairing warning
Driver’s side safety airbag
The resistance between the SRS safety airbag system connector clips connectors not within the designated scope
SRS safet y airbag system driver’s side airbag relative wiring harness shorting or shutoff
Possible
caus es Driver’s side safety airbag module failure
Clock spring internal failure
Failure of circuit connector clips between clock spring and SRS safety airbag system electronic-control unit
Shutoff or shorting of wiring harness between clock spring and SRS safety airbag system electronic-control unit.
Misconnection of SRS safety airbag system driver’s side airbag generator connector clip
Procedure Tes t Operation
Normal Next step
1 Check the clock spring
Warni ng
If not correctly handled, the safety airbag module may possibly be
trigged and released thus make serene damage to people. Therefore,
please carefully read the repairing warning before trouble handling.
Please take references in safety airbag system repairing warning.
Are the relative parts of clock spring normal? (The relation bet ween
stitches, unnecessary shutoff or shorting?) if the pr esent clock spring ca n
be replaced by a better one. Abnormal Replace the clock spring
Take references in the
removal/installation for
safety airbag system and
clock spring
Replace the driver’s side
safety airbag module
Tk f i th
Confirm the failure in driver’s side safety airbag module or other parts.
Rl thDAB dl ithbtt
Page 386 of 425
Safety airbag-16
Yes Next step
4 Confirm the failure in clock spring or other parts
configure the special tools fuel and t emperature diagnostic instrument
at 2Ω position
Install back the accumulator negative wire
Place the ignition switch in ON place
Any failure code in display? No Replace clock spring
Take references in the removal
and installation for safety airbag
system and clock spring.
Nor mal Replace SRS safety airbag
system unit; take references in
removal/installation of SRS
safety airbag system unit.
5 Check the wiring harness between clock spring and SRS safety airbag
system electronic-control unit
Place the ignition switch in LOCK position
Release accumulator negative wire and wait for 1 minute plus
Remove PAB trim cover, glove box (passengers’ side safety airbag is
under the trim cover)
Release the passengers’ side safety airbag module connector clip
Release all SRS safety airbag system unit connector clips
Check whether the following troubles are with the harness between
connector clips terminals of SRS safety airbag system unit and clock
spring
Grounding
Power-supply shorting
Shutoff
Is the previous wiring harness normal? Abnormal Replace the wire harness
Nor mal Next step
6 Check the clock spring connector clip
Remove the steering pillar shell
Release the clock spring connector clip
Is the clock spring connector clip normal? Abnormal Replace the wiring harness or
connector clips
Nor mal Next step
7 Check clock spring
Remove clock spring
Take references in removal/installation of safet y airbag system as
well as clock spring
Check clock spring
Take references in the test for safety airbag system and clock spring.
Is the clock spring normal? Abnormal Replace clock spring
Take references in the
removal/installation of safety
airbag system and clock spring.
Nor mal Next step
8 Check the wiring harness between clock spring and SRS safety airbag
system electronic-control unit
Place the ignition switch in LOCK position
Release accumulator negative wire and wait for 1 minute plus
Remove PAB trim cover, glove box (passengers’ side safety airbag is
under the trim cover)
Release the passengers’ side safety airbag module connector clip
Release all SRS safety airbag system unit connector clips.
Check whether the following troubles are with the harness between
connector clips terminals of SRS safety airbag system unit and spring
clock.
Grounding
Power-supply shorting
Shutoff
Is the previous harness normal? Abnormal Replace clock spring
Take references in the
removal/installation of safety
airbag system, and clock spring
Page 387 of 425
Safety airbag-17
Passengers’ side failure
Failure code
$9015
$9016
$9018
$9019 Passengers’ side safety airbag module (high or low resistance or shorting grounding)
Tes t co n d it i o n Warning
If not correctly handled, the safety airbag module as well as pretension safety belt may possibly be
trigged, released and tensioned, thus make serene damage to people. Therefore, please carefully read the
repairing warning before trouble handling. Please take references in safety airbag system repairing warning
If with passengers’ side safety airbag failure
The resistance between SRS safety airbag system unit connector clip stitch 13 and stitch 14 not within the
designated scope.
The wiring harness shorting between safety airbag system unit stitch 13 and stitch 14
Open loop between SRS safety airbag system unit connector clip stitch 13 and stitch 14,
Possible causes Passengers’ side safety airbag module failure
The failure of connector clip between passengers’ side safety airbag module and SRS safety airbag system
electronic-control unit
The failure of connector clip between SRS safety airbag system unit and grounding jumper.
The circuit shutoff or shorting between passengers’ side safety airbag module and SRS safety airbag system
electronic-control unit
The circuit shutoff or shorting between SRS safety airbag system unit and grounding jumper
SRS safety airbag system unit failure
Procedure Test Operation
Yes Next step
1 Is the vehicle with passengers’ side safety airbag module
No Step 5
Present failure code
Next step
Check passengers’ side safety airbag connector clips
Warning
Page 388 of 425
Safety airbag-18
Impact-vehicle diagnosis
Test SRS-ECU diagnostic signals
1. Connect the (X-431 diagnostic test’s) diagnostic joint
2. Read the diagnostic results with X-431 diagnostic tester
Repairing procedure
1.When safety airbag is released.
The following parts should be replaced with new ones
a. Passengers’ side safety airbag module
b. SRS-ECU
c. Driver’s side safety airbag module
2 Check the following parts; replace them with new ones providing something wrong with them.
a. Clock spring
b. Steering-wheel, steering column, bottom steering shaft module
3.Driver’s side safety airbag module’s installation status towards the steering wheel.
a. Check whether abnormal knocking is with the steering wheel, its activity is in good condition and its clearance is normal.
b. Check whether the wiring harness joint is broken and its terminal is deformed.
Caution: Due to the impact, the diagnostic instrument cannot communicate with SRS-ECU when accumulator is lack of
power, in this case, check and maintain the instrument panel wiring harness or utilize the extension power supply.
Page 389 of 425
Safety airbag-19
1. Check whether depression, crack or deformation is with the SRS-ECU bracket.
2. Check whether the joint is broken and terminal is deformed
3. Check SRS-ECU bracket’s installation status
a. Check whether depression, crack or deformation is with the shroud
b. Check whether the joint is broken, terminal is deformed and wiring harness is meshed.
c. Check whether depression, crack or deformation is with the gas generator shield.
d. Make sure the direction of the arrow is straightforward
4. Check the installation status of safety airbag module.
Driver’s side safety airbag module (the following Figure)
generator
bracketconnect the hornconnect the driver’s side
module
Clock spring (right Figure)
1. Check whether the joint and protecting tube are broken and the terminal is deformed.
2. Check whether the shield is deformed.
Steering wheel, steering column and bottom steering shaft module
1. Check the installation status of driver’s side safety airbag module
2. Check whether abnormal knocking is with the steering wheel and its clearance is normal
Passengers’ side safety airbag module (the following Figure)
1. Check the installation status of passengers’ side safety airbag module
2. Check whether the shield is deformed
Page 390 of 425
Safety airbag-20
Wiring harness joint (instrument cluster wiring harness)
Check whether the wiring harness is well installed, the joint is broken and the terminal is deformed.
Warning
The attentions for use and maintenance for SRS safety airbag are displayed in the Figure. Operate according to the sign and, the
destructed and dirty sign must be replaced with a new one steering
wheel in Figure6-1
Driver’s side safety airbag module in Figure 6.2
Clock spring in Figure 6.3
SRS-ECU in Figure 6.4
Sun visor in Figure 6.5
Passengers’ side safety airbag module in Figure 6.6
Passenger side airbag (PAB)