GREAT WALL HOVER 2006 Service Repair Manual

GREAT WALL HOVER 2006 Service Repair Manual HOVER 2006 GREAT WALL GREAT WALL https://www.carmanualsonline.info/img/59/57165/w960_57165-0.png GREAT WALL HOVER 2006 Service Repair Manual
Trending: service reset, 4WD, fuse diagram, overheating, change time, fuses, fuel cap

Page 361 of 425

GREAT WALL HOVER 2006  Service Repair Manual 
CD Player and Air Conditioning System-8
Step 6: Display  “06”(set  the temperature  zone)
Press  down  “Temp+”  switch
Display  the detection  code of mode/
temperature damper executor
Press

Page 362 of 425

GREAT WALL HOVER 2006  Service Repair Manual 
CD Player and Air Conditioning System-9
Step 9: display  “09”
Action of the executor mechanism:
Mode  damper: wind  to the  person  and the fee
Circulation damper: internal circulation
Temperatur

Page 363 of 425

GREAT WALL HOVER 2006  Service Repair Manual 
CD Player and Air Conditioning System-10
Refrigeration of air conditioner failed
T rou ble Des crip tion s Ana l ysis o f the Cause
1.No pick -up o f com pressor 1.
fuse burned down , com presso r’

Page 364 of 425

GREAT WALL HOVER 2006  Service Repair Manual 
CD Player and Air Conditioning System-11
b .Insufficient refrigeration output
T rou ble D escrip tion s Ana l ysis o f the Cause
I nad equate
re fri g eratio
n 1.
wind amount
is no rm al 1.
comp ress

Page 365 of 425

GREAT WALL HOVER 2006  Service Repair Manual 
CD Player and Air Conditioning System-12
e .Precautions  for the  overhaul  of air  cooling  system
When the air cooling  system encounters  the trouble,  the cause  for such  trouble  shall be analy

Page 366 of 425

GREAT WALL HOVER 2006  Service Repair Manual 
CD Player and Air Conditioning System-13
1 .CC6460K air conditioning system is designed with SD7V16 compressor, whose refrigeration oil type as
specified is SP-10P AG; hence application of other type

Page 367 of 425

GREAT WALL HOVER 2006  Service Repair Manual 
CD Player and Air Conditioning System-14
Pumping Out of A i r Conditioning  System to the Vacuum  and Addition  of Refrigeration  Oil
Connect the manifold  pressure gauge with the  pipe of air condit

Page 368 of 425

GREAT WALL HOVER 2006  Service Repair Manual CD Player and Air Conditioning System-15
Turn on the high-pressure valve on the manifold pressure gauge and inject the refrigerant to the system from high-pressure pipeline.
At this time, the attentio

Page 369 of 425

GREAT WALL HOVER 2006  Service Repair Manual CD Player and Air Conditioning System-16
refrigerant reservoir high-pressure pipelow pressure
high pressure
yellowred blueon on
low-pressure pipe
When judging the injection volume of the refrigerant,

Page 370 of 425

GREAT WALL HOVER 2006  Service Repair Manual CD Player and Air Conditioning System-17
Daily Maintenance of Air Conditioning System
In order to ensure normal operation of air conditioning system, maintenance and care services shall be frequently
Trending: weight, diagram, light, radiator cap, steering, Tune, stop start