change time INFINITI QX4 2001 Factory Owner's Manual
Page 743 of 2395
5 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº mode with CONSULT-II.
3. Select ªHO2S1 (B1)/(B2)º and ªHO2S1 MNTR (B1)/(B2)º.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch ªRECORDº on CONSULT-II screen.
SEF967Y
6. Check the following.
IªHO2S1 MNTR (B1)/(B2)º in ªDATA MONITORº mode changes from ªRICHº to ªLEANº to ªRICHº 5 times in 10 seconds.
5 times (cycles) are counted as shown below.
SEF647Y
IªHO2S1 (B1)/(B2)º voltage goes above 0.6V at least once.
IªHO2S1 (B1)/(B2)º voltage goes below 0.3V at least once.
IªHO2S1 (B1)/(B2)º voltage never exceeds 1.0V.
SEF648Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 8.
NG©GO TO 7.
DTC P0131, P0151 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(LEAN SHIFT MONITORING)
Diagnostic Procedure (Cont'd)
EC-208
Page 745 of 2395
SEF463R
SEF288D
Component DescriptionNBEC0101The heated oxygen sensor 1 (front) is placed into the front tube. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 (front) has a closed-end
tube made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions.
The heated oxygen sensor 1 (front) signal is sent to the ECM. The
ECM adjusts the injection pulse duration to achieve the ideal air-
fuel ratio. The ideal air-fuel ratio occurs near the radical change
from 1V to 0V.
CONSULT-II Reference Value in Data Monitor
Mode
NBEC0102Specification data are reference values.
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
IEngine: After warming upMaintaining engine speed at 2,000
rpm0 - 0.3V+,Approx. 0.6 - 1.0V
HO2S1 MNTR
(B1)
HO2S1 MNTR
(B2)LEAN+,RICH
Changes more than 5 times during
10 seconds.
ECM Terminals and Reference ValueNBEC0654Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
63 GHeated oxygen sensor
1 (front) (bank 1)[Engine is running]
IWarm-up condition
IEngine speed is 2,000 rpm.0 - Approximately 1.0V (Peri-
odically change)
SEF059V
DTC P0132, P0152 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RICH SHIFT MONITORING)
Component Description
EC-210
Page 747 of 2395
SEF336Z
SEF337Z
SEF655Y
WITH CONSULT-IINBEC0105S011) Start engine and warm it up to normal operating temperature.
2) Stop engine and wait at least 5 seconds.
3) Turn ignition switch ªONº and select ªHO2S1 (B1)/(B2) P0132/
P0152º of ªHO2S1º in ªDTC WORK SUPPORTº mode with
CONSULT-II.
4) Touch ªSTARTº.
5) Start engine and let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm after this step. If
the engine speed limit is exceeded, return to step 5.
6) When the following conditions are met, ªTESTINGº will be dis-
played on the CONSULT-II screen. Maintain the conditions
continuously until ªTESTINGº changes to ªCOMPLETEDº. (It
will take approximately 50 seconds or more.)
ENG SPEED 1,300 - 2,800 rpm
Vehicle speed 80 - 100 km/h (50 - 62 MPH)
B/FUEL SCHDL 3 - 10 msec
Selector lever Suitable position
If ªTESTINGº is not displayed after 5 minutes, retry from
step 2.
7) Make sure that ªOKº is displayed after touching ªSELF-DIAG
RESULTSº. If ªNGº is displayed, refer to ªDiagnostic
Procedureº, EC-213.
SEF308XB
Overall Function CheckNBEC0106Use this procedure to check the overall function of the heated oxy-
gen sensor 1 (front) circuit. During this check, a 1st trip DTC might
not be confirmed.
WITH GSTNBEC0106S011) Start engine and warm it up to normal operating temperature.
2) Set voltmeter probes between ECM terminal 63 (HO2S1 bank
1 right signal) or 62 (HO2S1 bank 2 left signal) and engine
ground.
3) Check one of the following with engine speed held at 2,000
rpm constant under no load.
IThe maximum voltage is below 0.8V at least one time.
IThe minimum voltage is below 0.35V at least one time.
4) If NG, go to ªDiagnostic Procedureº, EC-213.
DTC P0132, P0152 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RICH SHIFT MONITORING)
DTC Confirmation Procedure (Cont'd)
EC-212
Page 751 of 2395
6 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº mode with CONSULT-II.
3. Select ªHO2S1 (B1)/(B2)º and ªHO2S1 MNTR (B1)/(B2)º.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch ªRECORDº on CONSULT-II screen.
SEF967Y
6. Check the following.
IªHO2S1 MNTR (B1)/(B2)º in ªDATA MONITORº mode changes from ªRICHº to ªLEANº to ªRICHº 5 times in 10 seconds.
5 times (cycles) are counted as shown below.
SEF647Y
IªHO2S1 (B1)/(B2)º voltage goes above 0.6V at least once.
IªHO2S1 (B1)/(B2)º voltage goes below 0.3V at least once.
IªHO2S1 (B1)/(B2)º voltage never exceeds 1.0V.
SEF648Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 9.
NG©GO TO 8.
DTC P0132, P0152 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RICH SHIFT MONITORING)
Diagnostic Procedure (Cont'd)
EC-216
Page 753 of 2395
SEF463R
SEF288D
Component DescriptionNBEC0108The heated oxygen sensor 1 (front) is placed into the front tube. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 (front) has a closed-end
tube made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions.
The heated oxygen sensor 1 (front) signal is sent to the ECM. The
ECM adjusts the injection pulse duration to achieve the ideal air-
fuel ratio. The ideal air-fuel ratio occurs near the radical change
from 1V to 0V.
CONSULT-II Reference Value in Data Monitor
Mode
NBEC0109Specification data are reference values.
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
IEngine: After warming upMaintaining engine speed at 2,000
rpm0 - 0.3V+,Approx. 0.6 - 1.0V
HO2S1 MNTR
(B1)
HO2S1 MNTR
(B2)LEAN+,RICH
Changes more than 5 times during
10 seconds.
ECM Terminals and Reference ValueNBEC0655Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
63 GHeated oxygen sensor
1 (front) (bank 1)[Engine is running]
IWarm-up condition
IEngine speed is 2,000 rpm.0 - Approximately 1.0V (Peri-
odically change)
SEF059V
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Component Description
EC-218
Page 754 of 2395
TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
62 G/BHeated oxygen sensor
1 (front) (bank 2)[Engine is running]
IWarm-up condition
IEngine speed is 2,000 rpm.0 - Approximately 1.0V (Peri-
odically change)
SEF059V
SEF010V
On Board Diagnosis LogicNBEC0111To judge the malfunction of heated oxygen sensor 1 (front), this
diagnosis measures response time of heated oxygen sensor 1
(front) signal. The time is compensated by engine operating (speed
and load), fuel feedback control constant, and heated oxygen sen-
sor 1 (front) temperature index. Judgment is based on whether the
compensated time [heated oxygen sensor 1 (front) cycling time
index] is inordinately long or not.
Malfunction is detected when the response of the voltage signal
from the sensor takes more than the specified time.
Possible CauseNBEC0435IHarness or connectors
(The sensor circuit is open or shorted.)
IHeated oxygen sensor 1 (front)
IHeated oxygen sensor 1 heater (front)
IFuel pressure
IInjectors
IIntake air leaks
IExhaust gas leaks
IPCV valve
IMass air flow sensor
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
ECM Terminals and Reference Value (Cont'd)
EC-219
Page 764 of 2395
11 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº mode with CONSULT-II.
3. Select ªHO2S1 (B1)/(B2)º and ªHO2S1 MNTR (B1)/(B2)º.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch ªRECORDº on CONSULT-II screen.
SEF967Y
6. Check the following.
IªHO2S1 MNTR (B1)/(B2)º in ªDATA MONITORº mode changes from ªRICHº to ªLEANº to ªRICHº 5 times in 10 seconds.
5 times (cycles) are counted as shown below.
SEF647Y
IªHO2S1 (B1)/(B2)º voltage goes above 0.6V at least once.
IªHO2S1 (B1)/(B2)º voltage goes below 0.3V at least once.
IªHO2S1 (B1)/(B2)º voltage never exceeds 1.0V.
SEF648Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 14.
NG©GO TO 13.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-229
Page 766 of 2395
SEF463R
SEF288D
Component DescriptionNBEC0116The heated oxygen sensor 1 (front) is placed into the front tube. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 (front) has a closed-end
tube made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions.
The heated oxygen sensor 1 (front) signal is sent to the ECM. The
ECM adjusts the injection pulse duration to achieve the ideal air-
fuel ratio. The ideal air-fuel ratio occurs near the radical change
from 1V to 0V.
CONSULT-II Reference Value in Data Monitor
Mode
NBEC0117Specification data are reference values.
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
IEngine: After warming upMaintaining engine speed at 2,000
rpm0 - 0.3V+,Approx. 0.6 - 1.0V
HO2S1 MNTR
(B1)
HO2S1 MNTR
(B2)LEAN+,RICH
Changes more than 5 times during
10 seconds.
ECM Terminals and Reference ValueNBEC0656Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
63 GHeated oxygen sensor
1 (front) (bank 1)[Engine is running]
IWarm-up condition
IEngine speed is 2,000 rpm.0 - Approximately 1.0V (Peri-
odically change)
SEF059V
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0134, P0154 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(HIGH VOLTAGE)
Component Description
EC-231
Page 773 of 2395
5 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº mode with CONSULT-II.
3. Select ªHO2S1 (B1)/(B2)º and ªHO2S1 MNTR (B1)/(B2)º.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch ªRECORDº on CONSULT-II screen.
SEF967Y
6. Check the following.
IªHO2S1 MNTR (B1)/(B2)º in ªDATA MONITORº mode changes from ªRICHº to ªLEANº to ªRICHº 5 times in 10 seconds.
5 times (cycles) are counted as shown left:
SEF647Y
IªHO2S1 (B1)/(B2)º voltage goes above 0.6V at least once.
IªHO2S1 (B1)/(B2)º voltage goes below 0.3V at least once.
IªHO2S1 (B1)/(B2)º voltage never exceeds 1.0V.
SEF648Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 8.
NG©GO TO 7.
DTC P0134, P0154 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(HIGH VOLTAGE)
Diagnostic Procedure (Cont'd)
EC-238
Page 804 of 2395
1 right signal) or 71 (HO2S2 bank 2 left signal) and engine
ground.
4) Check the voltage when racing up to 4,000 rpm under no load
at least 10 times.
(Depress and release accelerator pedal as soon as possible.)
The voltage should change at more than 0.06V for 1 sec-
ond during this procedure.
If the voltage can be confirmed in step 4, step 5 is not
necessary.
5) Keep vehicle at idling for 10 minutes, then check the voltage.
Or check the voltage when coasting from 80 km/h (50 MPH)
in ªDº position with ªODº OFF.
The voltage should change at more than 0.06V for 1 sec-
ond during this procedure.
6) If NG, go to ªDiagnostic Procedureº, EC-272.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0139, P0159 HEATED OXYGEN SENSOR 2 (REAR) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Overall Function Check (Cont'd)
EC-269