battery INFINITI QX4 2005 Factory Owners Manual
Page 821 of 3419
BL-54
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
*1: when room lamp switch is in "DOOR" position.
*2: when hazard reminder is ON.
Terminals and Reference Value for IPDM E/REIS008Q2
*: when horn reminder is ON.63 L Room lampRoom lamp ON *1 Battery voltage
Room Lamp OFF *1 0
65 V All door lock actuators (lock)Door lock & unlock switch
(Neutral → Lock)0 → Battery voltage
66 G/YFront door lock actuator RH,
rear door lock actuators LH/
RH and back door lock actu-
ator (unlock)Door lock & unlock switch
(Neutral → Unlock)0 → Battery voltage
67 B Ground — 0
69 W/RRear power window power
supply— Battery voltage
70 W/B Battery power supply — Battery voltage Terminal Wire
ColorItem ConditionVoltage (V)
(Approx.)
Terminal Wire
ColorItem ConditionVoltage (V)
(Approx.)
38 B Ground — 0
39 L CAN-H — —
40 P CAN-L — —
45 G/W Horn relayWhen doors locks are operated
using keyfob (OFF → ON) *Battery voltage → 0
59 B Ground — 0
Page 826 of 3419
REMOTE KEYLESS ENTRY SYSTEM
BL-59
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Trouble Diagnosis ProcedureEIS0 08 Q6
1. Check the symptom and customer's requests.
2. Understand outline of system. Refer to BL-45, "
System Description" .
3. Confirm system operation.
Check that the power door lock system operates normally. Refer to BL-16, "POWER DOOR LOCK
SYSTEM" .
Check that the automatic back door system operates normally. Refer to BL-99, "AUTOMATIC BACK
DOOR SYSTEM" .
4. Perform pre-diagnosis inspection. Refer to BL-59, "
BCM Power Supply and Ground Circuit Check" .
5. Refer to trouble diagnosis chart by symptom, repair or replace any malfunctioning parts. Refer to BL-60,
"Trouble Diagnoses" .
6. Inspection End.
BCM Power Supply and Ground Circuit CheckEIS0 08 Q7
1. CHECK FUSE AND FUSIBLE LINK
Check the following BCM fuses and fusible link.
NOTE:
Refer to BL-44, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of problem before installing new fuse, refer to PG-4,
"POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM.
3. Check voltage between BCM connectors M18, M20 terminals
11, 38, 57, 70 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
Component Parts Terminal No. (SIGNAL) Ampere No. Location
BCM57 (BAT power supply) 15A 22 Fuse block (J/B)
70 (BAT power supply) 50AfFuse and fusible link box
11 (ACC power supply) 10A 4 Fuse block (J/B)
38 (IGN power supply) 10A 59 Fuse and relay box
ConnectorTerminals
Signal nameIgnition
switchVo l ta g e
(+) (–)
M2070
GroundBattery power
supplyOFFBattery
voltage
57Battery power
supplyOFFBattery
voltage
M1811ACC power
supplyACCBattery
voltage
38IGN power
supplyONBattery
voltage
WIIA0600E
Page 827 of 3419
BL-60
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
3. CHECK GROUND CIRCUIT
Check continuity between BCM connector M20 terminal 67 and
ground.
OK or NG
OK >> Power supply and ground circuit is OK.
NG >> Repair or replace harness.
Trouble DiagnosesEIS008Q8
SYMPTOM CHART
NOTE:
Always check the "Trouble Diagnosis Procedure" before troubleshooting. Refer to BL-59, "Trouble Diag-
nosis Procedure" .
Always check keyfob battery before replacing keyfob. Refer to BL-65, "Keyfob Battery and Function
Check" .
The panic alarm operation and power back door opener operation of remote keyless entry system do not
activate with the ignition key inserted in the ignition key cylinder.
Use Remote Keyless Entry Tester J-43241 (follow instructions on tester) to check operation of keyfob
before replacing keyfob.
ConnectorTe r m i n a l s
Continuity
(+) (-)
M20 67 Ground Yes
LIIA1040E
Symptom Diagnoses/service procedureReference
page
All functions of remote keyless entry system do not
operate.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Check BCM and keyless receiver.BL-66
The new ID of keyfob cannot be entered.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-652. Key switch and key lock solenoid (insert) checkBL-62
3. Door switch checkBL-63
4. ACC power checkBL-68
5. Replace BCM.BCS-20
Door lock or unlock does not function.
(If the power door lock system does not operate
manually, check power door lock system. Refer to
BL-16, "
POWER DOOR LOCK SYSTEM" )1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Replace BCM.BCS-20
Hazard and horn reminder does not activate prop-
erly when pressing lock or unlock button of keyfob.1. Check hazard and horn reminder mode with CONSULT-II
NOTE:
Hazard and horn reminder mode can be changed.
First check the hazard and horn reminder mode setting.BL-57,
"Active
Te s t"
2. Door switch checkBL-63
3. Replace BCM.BCS-20
Page 828 of 3419
REMOTE KEYLESS ENTRY SYSTEM
BL-61
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Hazard reminder does not activate properly when
pressing lock or unlock button of keyfob.
(Horn reminder OK)1. Check hazard reminder mode with CONSULT-II
NOTE:
Hazard reminder mode can be changed.
First check the hazard reminder mode setting.BL-57
2. Check hazard function with hazard switch —
3. Replace BCM.BCS-20
Horn reminder does not activate properly when
pressing lock or unlock button of keyfob.
(Hazard reminder OK)1. Check horn reminder mode with CONSULT-II
NOTE:
Horn reminder mode can be changed.
First check the horn reminder mode setting.BL-57
2. Check horn function with horn switch —
3. IPDM E/R operation checkBL-68
4. Replace BCM.BCS-20
Back door open/close operation is not carried out
with keyfob operation.
(The automatic back door system is normal.)1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Key switch (insert) checkBL-62
3. Check that glass hatch is closed —
4. Remote keyless entry receiver systemBL-66
5. Replace BCM.BCS-20
Room lamp, ignition keyhole illumination and step
lamp operation do not activate properly.1. Room lamp operation checkBL-70
2. Ignition keyhole illumination operation checkBL-70
3.Step lamp operation checkLT- 1 3 0
4. Door switch checkBL-63
5. Replace BCM.BCS-20
Panic alarm (horn and headlamp) does not activate
when panic alarm button is continuously pressed.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Key switch and key lock solenoid (insert) checkBL-62
3. Replace BCM.BCS-20
Auto door lock operation does not activate properly.
(All other remote keyless entry functions OK.)1. Check auto door lock operation mode with CONSULT-II
NOTE:
Auto door lock operation mode can be changed.
First check the auto door lock operation mode setting.BL-57
2. Replace BCM.BCS-20
Keyless power window down (open) operation does
not activate properly.
(All other remote keyless entry functions OK.)1. Check power window down operation mode with CONSULT-II
NOTE:
Power window down operation mode can be changed.
First check the power window down operation mode setting.BL-57
2. Check power window function with switch —
3. Replace BCM.BCS-20
Symptom Diagnoses/service procedureReference
page
Page 829 of 3419
BL-62
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
Key Switch (Insert) CheckEIS008Q9
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-27, "
DATA MONI-
TOR" .
When key is inserted to ignition key cylinder:
When key is removed from ignition key cylinder:
Without CONSULT-II
Check voltage between BCM connector M18 terminal 37 and
ground.
OK or NG
OK >> Key switch (insert) circuit is OK.
NG >> GO TO 2.
2. CHECK KEY SWITCH (INSERT)
1. Turn ignition switch OFF.
2. Disconnect key switch and key lock solenoid connector.
3. Check continuity between key switch and key lock solenoid terminals 3, 4.
OK or NG
OK >> Repair or replace harness.
NG >> Replace key switch.KEY ON SW : ON
KEY ON SW : OFF
LIIA0169E
ConnectorTe r m i n a l s
Condition Voltage (V)
(+) (–)
M18 37 GroundKey is inserted. Battery voltage
Key is removed. 0
LIIA0567E
Terminals Condition Continuity
3 – 4Key is inserted. Yes
Key is removed. No
LIIA1044E
Page 830 of 3419
REMOTE KEYLESS ENTRY SYSTEM
BL-63
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Door Switch CheckEIS008QA
1. CHECK DOOR SWITCHES INPUT SIGNAL
With CONSULT-II
Check door switches ("DOOR SW-DR", "DOOR SW-AS", "DOOR SW-RL", "DOOR SW-RR", "BACK DOOR
SW") in DATA MONITOR mode with CONSULT–II.Refer to BL-27, "
DATA MONITOR" .
When doors are open:
When doors are closed:
Without CONSULT-II
Check voltage between BCM connector M18 or M19 terminals 12,
13, 43, 47, 48 and ground.
OK or NG
OK >> Door switch circuit is OK.
NG >> GO TO 2.DOOR SW-DR : ON
DOOR SW-AS : ON
DOOR SW-RL : ON
DOOR SW-RR : ON
BACK DOOR SW : ON
DOOR SW-DR : OFF
DOOR SW-AS : OFF
DOOR SW-RL : OFF
DOOR SW-RR : OFF
BACK DOOR SW : OFF
LIIA0665E
Connector ItemTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
M19Back door
latch (door
ajar switch)43
GroundOpen
↓
Closed0
↓
Battery voltage Front door
switch LH47
Rear door
switch LH48
M18Front door
switch RH12
Rear door
switch RH13
LIIA1041E
Page 832 of 3419
REMOTE KEYLESS ENTRY SYSTEM
BL-65
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
4. CHECK BACK DOOR SWITCH GROUND
Check continuity between back door latch connector terminal 8 and
ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> Repair or replace harness.
Keyfob Battery and Function CheckEIS008QB
1. CHECK KEYFOB BATTERY
Remove battery and measure voltage across battery positive and negative terminals, (+) and (−).
NOTE:
Keyfob does not function if battery is not set correctly.
OK or NG
OK >> GO TO 2.
NG >> Replace battery.8 - Ground : Continuity should exist.
LIIA0828E
Voltage : 2.5V - 3.0V
SEL237W
Page 835 of 3419
BL-68
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
ACC Power CheckEIS008QD
1. CHECK ACC POWER
With CONSULT-II
Check "ACC ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-27, "
DATA MONITOR" .
Without CONSULT-II
Check voltage between BCM connector M18 terminal 11 and
ground.
OK or NG
OK >> ACC power circuit is OK.
NG >> Check the following:
10A fuse [No. 4, located in fuse block (J/B)]
Harness for open or short.
IPDM E/R Operation CheckEIS008QE
1. CHECK IPDM E/R INPUT VOLTAGE
Check voltage between IPDM E/R connector E122 terminal 45 and
ground.
OK or NG
OK >> Replace IPDM E/R.
NG >> GO TO 2.
Monitor Item Condition
ACC ON SWIgnition switch position ACC : ON
Ignition switch position OFF : OFF
PIIA3367E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
M18 11 GroundACC Battery voltage
OFF 0
PIIA7002E
ConnectorTe r m i n a l s
Voltage (V)
(Approx.)
(+) (–)
E122 45 Ground Battery voltage
LIIA1053E
Page 841 of 3419
BL-74
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
NOTE:
If a keyfob is lost, the ID code of the lost keyfob must be erased to prevent unauthorized use. A specific ID
code can be erased with CONSULT-II. However, when the ID code of a lost keyfob is not known, all con-
troller ID codes should be erased. After all ID codes are erased, the ID codes of all remaining and/or new
keyfobs must be re-registered.
To erase all ID codes in memory, register one ID code (keyfob) five times. After all ID codes are erased,
the ID codes of all remaining and/or new keyfobs must be re-registered.
When registering an additional keyfob, the existing ID codes in memory may or may not be erased. If five
ID codes are stored in memory, when an additional code is registered, only the oldest code is erased. If
less than five ID codes are stored in memory, when an additional ID code is registered, the new ID code is
added and no ID codes are erased.
If you need to activate more than two additional new keyfobs, repeat the procedure “Additional ID code
entry” for each new keyfob.
Entry of maximum five ID codes is allowed. When more than five ID codes are entered, the oldest ID code
will be erased.
Even if same ID code that is already in the memory is input, the same ID code can be entered. The code
is counted as an additional code.
Keyfob Battery ReplacementEIS008QK
LIIA1514E
Page 852 of 3419
VEHICLE SECURITY (THEFT WARNING) SYSTEM
BL-85
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Terminals and Reference Value for BCMEIS008QQ
Te r m i n a l Wire
ColorItem ConditionVoltage (V)
(Approx.)
11 O Ignition switch (ACC or ON) Ignition switch (ACC or ON position) Battery voltage
12 R/L Front door switch RH Door open (ON) → Door close (OFF) 0 → Battery voltage
13 GR Rear door switch RH Door open (ON) → Door close (OFF) 0 → Battery voltage
22 W/V BusWhen ignition switch is ON or power
window timer operates
23 G/OCombination meter (security
indicator lamp)Goes off → Illuminates (Every 2.4
seconds) Battery voltage → 0
39 L CAN-H — —
40 P CAN-L — —
42 GR Glass hatch ajar switchGlass hatch open (ON) → Glass
hatch close (OFF)Battery voltage → 0
43 R/BBack door latch (door ajar
switch)Door open (ON) → Door close (OFF) 0 → Battery voltage
47 SB Front door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
48 R/Y Rear door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
57 Y/R Battery power supply — Battery voltage
67 B Ground — 0
70 W/B Battery power supply — Battery voltage
PIIA2344E