turn signal INFINITI QX56 2006 Factory Service Manual
Page 2175 of 3383
GW-30
POWER WINDOW SYSTEM
Revision: November 20092006 QX56
Terminal and Reference Value for Main Power Window and Door Lock/Unlock
Switch
EIS005XS
Terminal and Reference Value for Power Window and Door Lock/Unlock Switch
RH
EIS005XT
Terminal Wire ColorItemCondition Voltage (V)
(Approx.)
2 W/B Limit switch and encoder ground — 0
4L Front door key cylinder switch LH
lock signal Key position
(Neutral
→ Unlocked) 5
→ 0
6R Front door key cylinder LH switch
unlock signal Key position
(Neutral
→ Locked) 5
→ 0
8G/R Front power window motor LH UP
signal When power window motor is
operated UP
Battery voltage
9 O Limit switch signal Front power window LH is
between fully-open and just
before fully-closed position (ON)
0
Front power window LH is
between just before fully-closed
position and fully-closed position
(OFF) 5
10 W/L RAP signal When ignition switch ON
Battery voltage
Within 45 seconds after ignition
switch is turned to OFF Battery voltage
More than 45 seconds after igni-
tion switch is turned to OFF 0
When front door LH or RH open
or power window timer operates 0
11 G/W Front power window motor LH
DOWN signal When power window motor is
operated DOWN
Battery voltage
13 G/Y Encoder pulse signal When power window motor oper-
ates
14 LG/W Power window serial link When ignition switch ON or
power window timer operates
15 BR Encoder power supply When ignition switch ON or
power window timer operates10
17 B Ground —0
19 W/R Battery power supply —Battery voltage
OCC3383D
PIIA2344J
Terminal Wire Color ItemCondition Voltage (V)
(Approx.)
3 W/B Limit switch and encoder ground — 0
4 G/R Encoder power supply When ignition switch ON or
power window timer operates10
Page 2177 of 3383
GW-32
POWER WINDOW SYSTEM
Revision: November 20092006 QX56
Terminal and Reference Value for BCMEIS005XU
Terminal Wire ColorItemCondition Voltage (V)
(Approx.)
11 O Ignition switch (ACC or ON) Ignition switch
(ACC or ON position) Battery voltage
12 R/L Front door switch RH signal ON (Open)
Battery voltage
OFF (Close) 0
22 W/V BUS When ignition switch ON or
power window timer operates
38 W/L Ignition switch (ON or START) Ignition switch
(ON or START position)
Battery voltage
47 SB Front door switch LH signal ON (Open)
Battery voltage
OFF (Close) 0
67 B Ground —0
68 W/L Power window power supply
(RAP) When ignition switch ON
Battery voltage
Within 45 seconds after ignition
switch is turned to OFF Battery voltage
More than 45 seconds after igni-
tion switch is turned to OFF 0
When front door LH or RH is
open or power window timer
operates 0
69 W/R Power window power supply
(BAT) —
Battery voltage
70 W/B Battery power supply —Battery voltage
PIIA2344J
Page 2178 of 3383
POWER WINDOW SYSTEMGW-33
C
DE
F
G H
J
K L
M A
B
GW
Revision: November 2009 2006 QX56
Work FlowEIS005XV
1. Check the symptom and customer's requests.
2. Understand the outline of system. Refer to GW-16, "
System Description" .
3. According to the trouble diagnosis chart, repair or replace the cause of the malfunction. Refer to GW-35, "
Trouble Diagnoses Symptom Chart" .
4. Does power window system operate normally? Yes, GO TO 5, If No, GO TO 3.
5. Inspection End.
CONSULT-II Function (BCM)EIS005XW
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT-II INSPECTION PROCEDURE
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carries out CAN communication.
1. Connect CONSULT-II and CONSULT-II CONVERTER to the data link connector.
2. Turn ignition switch ON.
3. Touch “START (NISSAN BASED VHCL) ”.
BCM diagnostic
test item Diagnostic mode
Content
Inspection by part WORK SUPPORT
Supports inspections and adjustments. Commands are transmitted to the BCM
for setting the status suitable for required operation, input/output signals are
received from the BCM and received data is displayed.
DATA MONITOR Displays BCM input/output data in real time. ACTIVE TEST Operation of electrical loads can be checked by sending drive signal to them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTR The results of transmit/receive diagnosis of CAN communication can be read. ECU PART NUMBER BCM part number can be read.CONFIGURATION Performs BCM configuration read/write functions.
BBIA0369E
BCIA0029E
Page 2179 of 3383
GW-34
POWER WINDOW SYSTEM
Revision: November 20092006 QX56
4. Touch “BCM”.
If “BCM ” is not indicated, refer to GI-40, "
CONSULT-II Data Link
Connector (DLC) Circuit" .
5. Touch “RETAINED PWR ”.
6. Select diagnosis mode. “ACTIVE TEST ”, “WORK SUPPORT ” and "DATA MONITOR"
are available.
ACTIVE TEST
WORK SUPPORT
DATA MONITOR
BCIA0030E
LIIA0163E
BCIA0031E
Test Item Description
RETAINED PWR This test is able to supply RAP signal (power) from BCM (body control module) to power window
system and power sunroof system (if equipped). Those systems can be operated when turning on
“
RETAINED PWR ” on CONSULT-II screen even if the ignition switch is turned OFF.
NOTE:
During this test, CONSULT-II can be operated with ignition switch in OFF position. “ RETAINED
PWR ” should be turned “ ON” or “OFF ” on CONSULT-II screen when ignition switch is ON. Then
turn ignition switch OFF to check retained power operation. CONSULT-II might be stuck if
“ RETAINED PWR ” is turned “ON ” or “OFF ” on CONSULT-II screen when ignition switch is OFF.
Work item Description
RETAINED PWR RAP signal
’s power supply period can be changed by mode setting. Selects RAP signal ’s power
supply period between three steps
MODE1 (45 sec.) / MODE2 (OFF) / MODE 3 (2 min.).
Work item Description
IGN ON SW Indicates (ON / OFF) condition of ignition switch
Page 2184 of 3383
POWER WINDOW SYSTEMGW-39
C
DE
F
G H
J
K L
M A
B
GW
Revision: November 2009 2006 QX56
4. CHECK BCM OUTPUT SIGNAL
1. Connect BCM.
2. Turn ignition switch ON.
3. Check voltage between BCM connector M20 terminals 68, 69 and ground.
OK or NG
OK >> Check the condition of the harness and the connector.
NG >> Replace BCM.
Power Window and Door Lock/Unlock Switch RH Power Supply and Ground
Circuit Check
EIS005Y0
1. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch ON.
2. Check voltage between power window and door lock/unlock switch RH connector D105 terminal 10 and ground.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect power window and door lock/unlock switch RH.
3. Check continuity between power window and door lock/unlock switch RH connector D105 terminal 11 and ground.
OK or NG
OK >> Power supply and ground circuit are OK.
NG >> Repair or replace harness.
3. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM.
3. Check continuity between BCM connector M20 (A) terminal 69 and power window and door lock/unlock switch RH connector
D105 (B) terminal 10.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness. 68 - Ground
: Battery voltage
69 - Ground : Battery voltage
LIIA0917E
10 - Ground : Battery voltage
LIIA1257E
11 - Ground: Continuity should exist.
LIIA1258E
69 - 10 : Continuity should exist.
LIIA2298E
Page 2185 of 3383
GW-40
POWER WINDOW SYSTEM
Revision: November 20092006 QX56
4. CHECK BCM OUTPUT SIGNAL
1. Connect BCM.
2. Turn ignition switch ON.
3. Check voltage between BCM connector M20 terminal 69 and ground.
OK or NG
OK >> Check the condition of the harness and the connector.
NG >> Replace BCM. Refer to BCS-20, "
BCM" .
Front Power Window Motor LH Circuit CheckEIS005Y1
1. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL
1. Turn ignition switch ON.
2. Check voltage between main power window and door lock/ unlock switch connector D7 terminals 8, 11 and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace main power window and door lock/unlock switch. Refer to EI-32, "
REMOVAL" .
2. CHECK POWER WINDOW MOTOR CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch and front power window motor LH.
3. Check continuity between main power window and door lock/ unlock switch connector D7 terminals 8, 11 and front power win-
dow motor LH connector D9 terminals 1, 2.
OK or NG
OK >> Replace front power window motor LH.
NG >> Repair or replace harness. Refer to GW-66, "
FRONT DOOR GLASS REGULATOR" .
69 - Ground
: Battery voltage
WIIA0508E
ConnectorTerminals
ConditionVoltage (V)
(Approx.)
(+) (-)
D7 8
Ground UP Battery voltage
DOWN 0
11 UP
0
DOWN Battery voltage
LIIA0317E
8 - 2 : Continuity should exist.
11 - 1 : Continuity should exist.
LIIA1260E
Page 2186 of 3383
POWER WINDOW SYSTEMGW-41
C
DE
F
G H
J
K L
M A
B
GW
Revision: November 2009 2006 QX56
Front Power Window Motor RH Circuit CheckEIS005Y2
1. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH OUTPUT SIGNAL
1. Connect power window and door lock/unlock switch RH.
2. Turn ignition switch ON.
3. Check voltage between power window and door lock/unlock switch RH connector D105 terminals 8, 9 and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace power window and door lock/unlock switch RH. Refer to EI-32, "
REMOVAL" .
2. CHECK FRONT POWER WINDOW MOTOR RH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front power window motor RH and power window and door lock/unlock switch RH.
3. Check continuity between power window and door lock/unlock switch RH connector D105 terminals 8, 9 and front power win-
dow motor RH connector D104 terminals 1, 2.
OK or NG
OK >> Replace front power window motor RH. Refer to GW-66,
"FRONT DOOR GLASS REGULATOR" .
NG >> Repair or replace harness.
Limit Switch Circuit Check Front LHEIS005Y3
1. CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH LIMIT SIGNAL
1. Turn ignition switch ON.
2. Check voltage between main power window and door lock/ unlock switch connector D7 termimal 9 and ground.
OK or NG
OK >> Limit switch circuit is OK.
NG >> GO TO 2.
Connector Terminals
ConditionVoltage (V)
(Approx.)
(+) (-)
D105 9
Ground UP
0
DOWN Battery voltage
8 UP Battery voltage
DOWN 0
LIIA1261E
8 - 2 : Continuity should exist.
9 - 1 : Continuity should exist.
LIIA1262E
ConnectorTerminal
Condition Voltage (V)
(Approx.)
(+) (-)
D7 9 Ground Front power window LH is
between fully-open and just
before fully-closed position
(ON)
0
Front power window LH is
between just before fully-
closed position and fully-
closed position (OFF) 5
LIIA0339E
Page 2187 of 3383
GW-42
POWER WINDOW SYSTEM
Revision: November 20092006 QX56
2. CHECK FRONT POWER WINDOW MOTOR LH LIMIT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect front power window motor LH.
3. Turn ignition switch ON.
4. Check voltage between front power window motor LH connector D9 terminal 5 and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 5.
3. CHECK LIMIT SWITCH GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between front power window motor LH connec- tor D9 terminal 6 and ground.
OK or NG
OK >> Replace front power window motor LH. Refer to GW-66,
"FRONT DOOR GLASS REGULATOR" .
NG >> GO TO 4.
4. CHECK HARNESS CONTINUITY
1. Disconnect main power window and door lock/unlock switch.
2. Check continuity between front power window motor LH connec- tor D9 terminal 6 and main power window and door lock/unlock
switch connector D7 terminal 2.
OK or NG
OK >> Replace main power window and door lock/unlock switch. Refer to EI-32, "
REMOVAL" .
NG >> Repair or replace harness.
5. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch.
3. Check continuity between front power window motor LH connec- tor D9 terminal 5 and main power window and door lock/unlock
switch connector D7 terminal 9.
OK or NG
OK >> Replace main power window and door lock/unlock switch. Refer to EI-32, "
REMOVAL" .
NG >> Repair or replace harness. 5 - Ground : Approx. 5V
LIIA0922E
6 - Ground
: Continuity should exist.
LIIA0923E
6 - 2: Continuity should exist.
LIIA0924E
5 - 9: Continuity should exist.
LIIA0925E
Page 2188 of 3383
POWER WINDOW SYSTEMGW-43
C
DE
F
G H
J
K L
M A
B
GW
Revision: November 2009 2006 QX56
Limit Switch Circuit Check Front RHEIS005Y4
1. CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH LIMIT SIGNAL
1. Turn ignition switch ON.
2. Check voltage between power window motor RH connector D105 terminal 15 and ground.
OK or NG
OK >> Limit switch circuit is OK.
NG >> GO TO 2.
2. CHECK FRONT POWER WINDOW MOTOR RH LIMIT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect front power window motor RH.
3. Turn ignition switch ON.
4. Check voltage between front power window motor RH connector D104 terminal 5 and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 5.
3. CHECK LIMIT SWITCH GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between front power window motor RH con- nector D104 terminal 6 and ground.
OK or NG
OK >> Replace front power window motor RH. Refer to GW-66,
"FRONT DOOR GLASS REGULATOR" .
NG >> GO TO 4.
Connector Te r m i n a l s
Condition Voltage (V)
(Approx.)
(+) (-)
D105 15 Ground Front power window RH is
between fully-open and just
before fully-closed position
(ON)
0
Front power window RH is
between just before fully-
closed position and fully-
closed position (OFF) 5
LIIA1263E
5 - Ground
: Approx. 5V
LIIA0922E
6 - Ground: Continuity should exist.
LIIA0923E
Page 2190 of 3383
POWER WINDOW SYSTEMGW-45
C
DE
F
G H
J
K L
M A
B
GW
Revision: November 2009 2006 QX56
3. CHECK ENCODER GROUND
1. Turn ignition switch OFF.
2. Check continuity between front power window motor LH connec- tor D9 terminal 6 and ground.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. CHECK ENCODER GROUND CIRCUIT
1. Disconnect main power window and door lock/unlock switch.
2. Check continuity between front power window motor LH connec- tor D9 terminal 6 and main power window and door lock/unlock
switch connector D7 terminal 2.
OK or NG
OK >> Replace main power window and door lock/unlock switch. Refer to EI-32, "
REMOVAL" .
NG >> Repair or replace harness.
5. CHECK ENCODER SIGNAL
1. Connect front power window motor LH.
2. Turn ignition switch ON.
3. Check the signal between main power window and door lock/ unlock switch connector and ground with oscilloscope.
OK or NG
OK >> Replace main power window and door lock/unlock switch. Refer to EI-32, "REMOVAL" .
NG >> GO TO 6. 6 - Ground
: Continuity should exist.
LIIA0923E
6 - 2: Continuity should exist.
LIIA0924E
Connec-
tor Terminals
Condition Signal
(+) (-)
D7 13 Ground Opening
LIIA0364E
OCC3383D