SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-314
STEP 8. Check the input signal by using "FUNCTION
DIAG." menu of the SWS monitor.
If the Ignition switch is turned to the "ON" position and the
turn-signal lamp switch (LH) is turned on, normal conditions
should be displayed for the items described in the table below.
(1) Operate Diagnostic Tool MB991958 according to the
procedure below to display "TURN SIG.LH."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f. Select "TURN SIGNAL."
g. Select "TURN SIG.LH."
(2) Check that normal conditions are displayed for the item
described in the table below.
Q: Do the Diagnostic Tool display the item "T/S LH SW" as
normal condition?
YES : Replace the ETACS-ECU. Verify that the turn-signal
lamps illuminate normally.
NO : Refer to Inspection Procedure M-5 "ETACS-ECU
does not receive any signal from the turn-signal lamp
switch P.54B-420."
INSPECTION PROCEDURE I-2: Flasher Timer: Hazard warning lamps do not flash when the hazard
warning lamp switch is turned on.
.
CIRCUIT OPERATION
If the ETACS-ECU receives "ON" signal from the
hazard warning lamp switch, the ETACS-ECU turns
on the flasher timer (incorporated in the
ETACS-ECU), thus causing the turn-signal lamps to
flash.
.
TECHNICAL DESCRIPTION (COMMENT)
If the hazard warning lamps do not flash, the power
supply line to the ETACS-ECU (dedicated to the
turn-signal lamps) or the ETACS-ECU may be defec-
tive.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective ITEM No. ITEM NAME NORMAL CONDITION
ITEM 11 T/S LH SW ON

Page 315 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-315
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
STEP 1. Check the turn-signal lamps.
Q: Do the turn-signal lamps illuminate normally?
YES : Go to Step 2.
NO : Refer to Inspection Procedure I-1 "Turn-signal lamps
do not flash when the turn-signal lamp switch is
turned on P.54B-310."
STEP 2. Check the input signal (by using the pulse check
mode of the monitor).
Check input signal from the hazard warning lamp switch.
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Operate Diagnostic Tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(3) Check that Diagnostic Tool MB991958 sounds when the
hazard warning lamp switch is turned from "OFF" to "ON."
Q: Does Diagnostic Tool MB991958 sound when the hazard
warning lamp switch is turned from "OFF" to "ON"?
YES : Replace the ETACS-ECU. Verify that the hazard
warning lamps illuminate normally.
NO : Refer to Inspection Procedure N-2 "ETACS-ECU
does not receive any signal from the hazard warning
lamp switch P.54B-436."

Page 335 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-335
NOTE: Also check junction block connector C-204 for loose,
corroded, or damaged terminals, or terminals pushed back in
the connector. If junction block connector C-204 is damaged,
repair or replace the damaged component(s) as described in
GROUP 00E, Harness Connector Inspection P.00E-2.
Q: Is the wiring harness between rear combination lamp
(RH) connector F-03 (terminal 5) and ETACS-ECU
connector C-219 (terminal 9) in good condition?
YES : Replace the rear combination lamp socket assembly
(RH). Verify that the turn-signal lamps illuminate
normally.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that
the turn-signal lamps illuminate normally.
INSPECTION PROCEDURE I-4: The turn-signal lamp indicator does not illuminate normally.
NOTE: This troubleshooting procedure requires the
use of Diagnostic Tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
At the same time that the turn-signal lamps are illu-
minated, the ETACS-ECU sends a signal to illumi-
nate the turn-signal lamp indicator via the CAN bus
line.
.
TECHNICAL DESCRIPTION (COMMENT)
If the turn-signal indicator does not illuminate nor-
mally, connector(s), wiring harness in the CAN bus
lines, the ETACS-ECU or the combination meter may
be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The combination meter may be defective
The ETACS-ECU may be defective
.

Page 336 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-336
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
MB991813: SWS Monitor Kit
MB991806: SWS Monitor Cartridge
MB991812: SWS Monitor Harness (For Column-ECU)
MB991822: Test Probe Harness
STEP 1. Check the turn-signal lamps.
When the column switch or the hazard warning lamp switch are
operated, check that the turn-signal lamps illuminate and go off
normally.
Q: Are the turn-signal lamps in good condition?
YES : Go to Step 2.
NO : First, repair the turn-signal lamp(s). Refer to
Inspection Procedure I-3 "One of the turn-signal
lamps does not illuminate P.54B-316."
STEP 2. Using Diagnostic Tool MB991958, diagnose the
CAN bus line.
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958.
(1) Connect Diagnostic Tool MB991958.Refer to "How to
connect SWS monitor P.54B-13."
(2) Turn the ignition switch to the "ON" position.
(3) Diagnose the CAN bus line.
(4) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the CAN bus line found to be normal?
YES : Go to Step 3.
NO : Repair the CAN bus line (Refer to GROUP 54C,
Diagnosis P.54C-15).

Page 337 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-337
STEP 3. Using Diagnostic Tool MB991958, read the
combination meter diagnostic trouble code.
Check whether the combination meter-related DTC is set.
(1) Turn the ignition switch to the "ON" position.
(2) Check whether a combination meter-related DTC is set.
(3) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the DTC set?
YES : Diagnose the combination meter. Refer to P.54A-48.
NO : Go to Step 4.

Page 338 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-338
STEP 4. Use Diagnostic Tool MB991958 to select "ECU
COMM Check" on the SWS monitor display.
Check the ETACS-ECU.
Connect special tool MB991910 before connecting special
tool MB991812. Be sure to connect special tool MB991806
after turning on special tool MB991824.
(1) Connect the SWS monitor. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "ON" position.
(3) Operate Diagnostic Tool MB991958 according to the
procedure below to display "ECU COMM Check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."
(4) Diagnostic Tool MB991958 should show "OK" on the "ECU
COMM Check" menu for the "ETACS ECU" menu.
Q: Is "OK" displayed for the "ETACS ECU" menu?
YES : Go to Step 5.
NO : Refer to Inspection Procedure A-3 "Communication
with the ETACS-ECU is not possible P.54B-74."
STEP 5. Replace the combination meter.
(1) Replace the combination meter.
(2) Check that the turn-signal lamp indicator lamps illuminate
normally.
Q: Are the turn-signal indicator lamps in good condition?
YES : No action is necessary and testing is complete.
NO : Replace the ETACS-ECU. Check that the turn-signal
lamp indicator lamps illuminate normally.

Page 340 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-340
INSPECTION PROCEDURE J-1: Fog Light: Fog lamps do not illuminate when the fog lamp switch is
turned on.
NOTE: This troubleshooting procedure requires the
use of Diagnostic Tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
The ETACS-ECU sends a fog lamp illumination
request signal ("LAMP ON" signal) to the
front-ECU when the fog lamp switch is turned on
while the headlamps are illuminating at low
beam.
Then the front-ECU switches on its relay to illumi-
nate the fog lamps.
.
TECHNICAL DESCRIPTION (COMMENT)
If the headlamps illuminate at low beam, the fog
lamp relay, the fog lamp switch, the front-ECU or the
ETACS-ECU may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The fog lamp relay may be defective
The front-ECU may be defective
The ETACS-ECU may be defective
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
MB991813: SWS Monitor Kit
MB991806: SWS Monitor Cartridge
MB991812: SWS Monitor Harness (For Column-ECU)
MB991822: Test Probe Harness
STEP 1. Check the headlamp (low-beam) operation.
Q: Do the headlamps illuminate at low beam normally?
YES : Go to Step 2.
NO : Refer to Inspection Procedure H-2 "The headlamps
(low-beam) do not illuminate normally P.54B-264."

Page 341 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-341
STEP 2. Check the input signal by using "FUNCTION
DIAG." menu of the SWS monitor.
Set each switch to the following condition before checking input
signal from the fog lamp switch:
Ignition switch: ON
Fog lamp switch: ON
NOTE: Turn the ignition switch to the "ON" position in order to
disable the headlamp automatic shutdown function.
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Operate Diagnostic Tool MB991958 according to the
procedure below to display "F.FOG."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f. Select "LIGHTING."
g. Select "F.FOG."
(3) Check that normal conditions are displayed for the items
described in the table below.
Q: Does the Diagnostic Tool MB991958 display the items
"IG SW (IG1)" and "F.FOG LAMP" as normal condition?
Normal conditions are displayed for all the items : Go to
St e p 3 .
Normal condition is not displayed for "IG SW (IG1)" :
Refer to Inspection Procedure M-2 "ETACS-ECU
does not receive any signal from the ignition switch
(IG1) P.54B-408."
Normal condition is not displayed for "F.FOG LAMP" :
Refer to Inspection Procedure M-3 "ETACS-ECU
does not receive any signal from the fog lamp switch
P.54B-410." ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 30 IG SW (IG1) ON
ITEM 36 F.FOG LAMP ON

Page 350 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-350
STEP 13. Check the wiring harness between fog lamp relay
connector A-05X (terminal 4) and fog lamp (RH) connector
A-28 (terminal 1).
Q: Is the wiring harness between fog lamp relay connector
A-05X (terminal 4) and fog lamp (RH) connector A-28
(terminal 1) in good condition?
YES : No action is necessary and testing is complete.
NO : The wiring harness may be damaged or the
connector(s) may have loose, corroded or damaged
terminals, or terminals pushed back in the connector.
Repair the wiring harness as necessary. Verify that
the fog lamps illuminate normally.
INSPECTION PROCEDURE J-4: The fog lamp indicator does not illuminate normally.
NOTE: This troubleshooting procedure requires the
use of Diagnostic Tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.

Page 352 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-352
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
MB991813: SWS Monitor Kit
MB991806: SWS Monitor Cartridge
MB991812: SWS Monitor Harness (For Column-ECU)
MB991822: Test Probe Harness
STEP 1. Check the fog lamps.
When the fog lamp switch is operated, check that the fog lamps
illuminate/go off normally.
Q: Are the fog lamps operating properly?
YES : Go to Step 2.
NO : First, repair the fog lamps. Refer to Inspection
Procedure J-3 "One of the fog lamps does not
illuminate P.54B-345."
STEP 2. Using Diagnostic Tool MB991958, diagnose the
CAN bus line.
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958.
(1) Connect Diagnostic Tool MB991958. Refer to "How to
connect SWS monitor P.54B-13."
(2) Turn the ignition switch to the "ON" position.
(3) Diagnose the CAN bus line.
(4) Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the CAN bus line found to be normal?
YES : Go to Step 3.
NO : Repair the CAN bus line (Refer to GROUP 54C,
Diagnosis P.54C-15).