NISSAN ALMERA 2001 Service Manual

Page 1691 of 2898

5 CHECK FRONT DOOR UNLOCK SENSOR
1. Disconnect front door unlock sensor harness connector.
2. Check continuity between door unlock sensor terminals.
SEL988W
OK or NG
OK©Check the following.
+Door unlock sensor ground circuit
+Harness for open or short between time control unit and door unlock sensor
NG©Replace door unlock sensor.
6 CHECK DOOR SWITCHES INPUT SIGNAL
Check voltage between time control unit harness connector terminal 7 and ground.
SEL432X
OK or NG
OK©GO TO 8.
NG©GO TO 7.
INTERIOR ROOM LAMP
Trouble Diagnoses/Hatchback With Interior Room Lamp Timer (Cont'd)
EL-133

Page 1692 of 2898

7 CHECK DOOR SWITCHES
1. Disconnect door switch harness connector.
2. Check continuity between door switch terminal 1 and ground.
SEL794WA
OK or NG
OK©Check the following.
+Door switch ground condition
+Harness for open or short between time control unit and door switch
NG©Replace door switch.
8 CHECK KEY SWITCH INPUT SIGNAL
Check voltage between time control unit harness connector terminal 22 and ground.
SEL433X
OK or NG
OK©Replace time control unit.
NG©GO TO 9.
INTERIOR ROOM LAMP
Trouble Diagnoses/Hatchback With Interior Room Lamp Timer (Cont'd)
EL-134

Page 1693 of 2898

9 CHECK KEY SWITCH (INSERT)
Check continuity between terminals 1 and 2.
YEL786C
OK or NG
OK©Check the following.
+10A fuse [No. 12, located in fuse block (J/B)]
+Harness for open or short between key switch and fuse
+Harness for open or short between time control unit and key switch
NG©Replace key switch.
INTERIOR ROOM LAMP
Trouble Diagnoses/Hatchback With Interior Room Lamp Timer (Cont'd)
EL-135

Page 1694 of 2898

DIAGNOSTIC PROCEDURE 2=NJEL0437S02SYMPTOM: Interior lamp timer does not cancel properly.
1 CHECK IGNITION ON SIGNAL
Check voltage between time control unit harness connector terminal 1 and ground.
SEL429X
OK or NG
OK©GO TO 2.
NG©Check the following.
+10A fuse [No. 10, located in fuse block (J/B)]
+Harness for open or short between time control unit and fuse
2 CHECK DOOR SWITCH INPUT SIGNAL
Check voltage between time control unit harness connector terminal 6 and ground.
SEL430X
OK or NG
OK©GO TO 4.
NG©GO TO 3.
INTERIOR ROOM LAMP
Trouble Diagnoses/Hatchback With Interior Room Lamp Timer (Cont'd)
EL-136

Page 1695 of 2898

3 CHECK DRIVER SIDE DOOR SWITCH
Check continuity between terminals 2 and 3.
SEL325WA
OK or NG
OK©Check the following.
+Driver side door switch ground circuit and condition
+Harness for open or short between time control unit and driver side door switch
NG©Replace driver side door switch.
4 CHECK FRONT DOOR UNLOCK SENSOR INPUT SIGNAL
Check voltage between time control unit harness connector terminal 35 and ground.
SEL431X
OK or NG
OK©Replace time control unit.
NG©GO TO 5.
INTERIOR ROOM LAMP
Trouble Diagnoses/Hatchback With Interior Room Lamp Timer (Cont'd)
EL-137

Page 1696 of 2898

5 CHECK FRONT DOOR UNLOCK SENSOR
1. Disconnect front door unlock sensor harness connector.
2. Check continuity between door unlock sensor terminals.
SEL988W
OK or NG
OK©Check the following.
+Door unlock sensor ground circuit
+Harness for open or short between time control unit and door unlock sensor
NG©Replace door unlock sensor.
INTERIOR ROOM LAMP
Trouble Diagnoses/Hatchback With Interior Room Lamp Timer (Cont'd)
EL-138

Page 1697 of 2898

Wiring Diagram Ð ROOM/L Ð/Sedan Without
Timer
NJEL0318
HEL379B
INTERIOR ROOM LAMP
Wiring Diagram Ð ROOM/L Ð/Sedan Without Timer
EL-139

Page 1698 of 2898

Wiring Diagram Ð ROOM/L Ð/Hatchback
Without Timer
NJEL0438
MEL945L
INTERIOR ROOM LAMP
Wiring Diagram Ð ROOM/L Ð/Hatchback Without Timer
EL-140

Page 1699 of 2898

Wiring Diagram Ð INT/L Ð/SedanNJEL0319
HEL875A
SPOT AND TRUNK ROOM LAMPS
Wiring Diagram Ð INT/L Ð/Sedan
EL-141

Page 1700 of 2898

HEL666B
SPOT AND TRUNK ROOM LAMPS
Wiring Diagram Ð INT/L Ð/Sedan (Cont'd)
EL-142

Page:   < prev 1-10 ... 1651-1660 1661-1670 1671-1680 1681-1690 1691-1700 1701-1710 1711-1720 1721-1730 1731-1740 ... 2900 next >