fuse NISSAN VERSA 2006 Workshop Service Repair Manual

Page 2593 of 2896

FUSE AND FUSIBLE LINK BOX
PG-77
C
D
E
F
G
H
I
J
L
MA
B
PG
Revision: June 20062007 Versa
FUSE AND FUSIBLE LINK BOXPFP:24382
Terminal ArrangementEKS00I65
WKIA5604E

Page 2594 of 2896

PG-78
FUSE AND FUSIBLE LINK BOX
Revision: June 20062007 Versa

Page 2628 of 2896

RF-10
SUNROOF
Revision: June 20062007 Versa
SUNROOFPFP:91210
Component Parts and Harness Connector LocationEIS009BG
System DescriptionEIS009BH
OUTLINE
Electric sunroof system consists of
Sunroof switch
Sunroof motor assembly
BCM (body control module)
BCM supplies power to the sunroof motor. Sunroof operation depends on sunroof switch condition.
OPERATION
Power is supplied at all times
through 40A fusible link (letter g , located in the fuse and fusible link box)
to BCM terminal 70, and
through BCM terminal 69
to sunroof motor assembly terminal 7.
When the ignition switch is in the ON or START position, power is supplied
through 10A fuse [No.6, located in the fuse block (J/B)]
to BCM terminal 38, and
through BCM terminal 68
to sunroof motor assembly terminal 9.
Ground is supplied
to BCM terminal 67
LIIA2597E
1. BCM M18, M19, M20 (view with
glove box removed)2. Sunroof switch R6 3. Sunroof motor assembly R4
4. Front door switch LH B8, RH B108

Page 2684 of 2896

SC-10
STARTING SYSTEM
Revision: June 20062007 Versa
STARTING SYSTEMPFP:23300
System DescriptionEKS00IB0
M/T MODELS
Power is supplied at all times
to starter motor terminal B, and
through 40A fusible link (letter h , located in the fuse and fusible link box)
to ignition switch terminal B.
With the ignition switch in the START position, power is supplied
from ignition switch terminal ST
to IPDM E/R terminal 21.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse (No. 49, located in the IPDM E/R)
to the clutch interlock switch terminal 1.
With the clutch pedal depressed, power is supplied
through the clutch interlock switch terminal 2
to IPDM E/R terminal 35.
Ground is supplied at all times
to IPDM E/R terminals 39 and 59
through body grounds E15 and E24.
If the IPDM E/R receives a starter relay request ON signal from the BCM over the CAN communication lines,
the IPDM E/R grounds the starter relay and power is supplied
through terminal 19 of the IPDM E/R
to terminal S of the starter motor.
The starter motor magnetic switch energizes closing the circuit between the battery and the starter motor. The
starter motor is case ground through the cylinder block. With power and ground supplied, the starter motor
operates.
A/T MODELS
Power is supplied at all times
to starter motor terminal B, and
through 40A fusible link (letter h , located in the fuse and fusible link box)
to ignition switch terminal B.
With the ignition switch in the START position, power is supplied
from ignition switch terminal ST
to IPDM E/R terminal 21.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse (No. 54, located in the IPDM E/R)
to park/neutral position (PNP) switch terminal 1.
With the selector lever in the P or N position, power is supplied
through PNP switch terminal 2
to IPDM E/R terminal 35.
Ground is supplied at all times
to IPDM E/R terminals 39 and 59
through body grounds E15 and E24.
If the IPDM E/R receives a starter relay request ON signal from the BCM over the CAN communication lines,
the IPDM E/R grounds the starter relay and power is supplied
through terminal 19 of the IPDM E/R
to terminal S of the starter motor.

Page 2685 of 2896

STARTING SYSTEM
SC-11
C
D
E
F
G
H
I
J
L
MA
B
SC
Revision: June 20062007 Versa
The starter motor magnetic switch energizes closing the circuit between the battery and the starter motor. The
starter motor is case ground through the cylinder block. With power and ground supplied, the starter motor
operates.
CVT MODELS
Power is supplied at all times
to starter motor terminal B, and
through 40A fusible link (letter h , located in the fuse and fusible link box)
to ignition switch terminal B.
With the ignition switch in the START position, power is supplied
from ignition switch terminal ST
to IPDM E/R terminal 21.
With the selector lever in the P or N position, power is supplied
from the transmission control module (TCM) terminal 24
to IPDM E/R terminal 35.
Ground is supplied at all times
to IPDM E/R terminals 39 and 59
through body grounds E15 and E24.
If the IPDM E/R receives a starter relay request ON signal from the BCM over the CAN network, the IPDM E/
R grounds the starter relay and power is supplied
through terminal 19 of the IPDM E/R
to terminal S of the starter motor.
The starter motor magnetic switch energizes closing the circuit between the battery and the starter motor. The
starter motor is case ground through the cylinder block. With power and ground supplied, the starter motor
operates.

Page 2694 of 2896

SC-20
STARTING SYSTEM
Revision: June 20062007 Versa
DIAGNOSTIC PROCEDURE 1
Check Starter Motor Circuit
1. CHECK POWER SUPPLY TO STARTER MOTOR
1. Remove the fuel pump fuse.
2. Crank or start the engine (where possible) until the fuel pressure is released.
3. Turn the ignition switch OFF.
4. Check that the starter motor connector F27 connection is clean and tight.
5. Check voltage between starter motor connector F27 terminal B
and ground using a digital circuit tester.
OK or NG
OK >> GO TO 2.
NG >> Check harness between the battery and the starter
motor for open circuit.
2. CHECK VOLTAGE DROP ON STARTER MOTOR CIRCUIT
1. Check voltage between starter motor connector F27 terminal B
and battery positive terminal using a digital circuit tester.
OK or NG
OK >> GO TO 3.
NG >> Check harness between the battery and the starter
motor for poor continuity.
3. CHECK VOLTAGE DROP ON STARTER MOTOR GROUND CIRCUIT
1. Check voltage between starter motor case and battery negative
terminal using a digital circuit tester.
OK or NG
OK >> Starter motor ground circuit is OK. Further inspection is
necessary. Refer to SC-19, "
WORK FLOW" .
NG >> Check harness between the starter motor case and
ground for poor continuity. Battery voltage should exist
WKIA0137E
Ignition switch in
START: Less than 0.2V
WKIA0138E
Ignition switch in
START: Less than 0.2V
WKIA0139E

Page 2695 of 2896

STARTING SYSTEM
SC-21
C
D
E
F
G
H
I
J
L
MA
B
SC
Revision: June 20062007 Versa
DIAGNOSTIC PROCEDURE 2
Check Magnetic Switch Circuit
1. CHECK POWER SUPPLY TO MAGNETIC SWITCH
1. Remove the fuel pump fuse.
2. Crank or start the engine (where possible) until the fuel pressure is released.
3. Turn the ignition switch OFF.
4. Disconnect starter motor connector F28.
5. Check voltage between starter motor connector F28 terminal S
and ground using a digital circuit tester.
OK or NG
OK >> GO TO 2.
NG >> Check the following:
40A fusible link (letter h , located in fuse and fusible
link box)
10A fuse (No. 49, M/T models, located in the IPDM E/
R)
15A fuse (No. 52, located in the IPDM E/R)
20A fuse (No. 53, located in the IPDM E/R)
PNP switch, clutch interlock switch or TCM depending on equipment
Ignition switch
Ignition relay IPDM E/R
Starter relay IPDM E/R
Starter relay request ON signal from BCM
Harness for open or short circuit
2. CHECK VOLTAGE DROP ON MAGNETIC SWITCH CIRCUIT
1. Connect starter motor connector F28.
2. Check voltage between starter motor connector F28 terminal S
and battery positive terminal using a digital circuit tester.
OK or NG
OK >> Magnetic switch circuit is OK. Further inspection is nec-
essary. Refer to SC-19, "
WORK FLOW" .
NG >> Check harness, components and connections between
the battery and the magnetic switch for poor continuity. Ignition switch in
START: Battery voltage
WKIA5243E
Ignition switch in
START: Less than 1V
WKIA5244E

Page 2698 of 2896

SC-24
CHARGING SYSTEM
Revision: June 20062007 Versa
CHARGING SYSTEMPFP:23100
System DescriptionEKS00IB3
The generator provides DC voltage to operate the vehicle's electrical system and to keep the battery charged.
The voltage output is controlled by the IC regulator.
Power is supplied at all times to generator terminal 3 through
10A fuse (No. 29, located in the fuse and fusible link box).
Power is supplied through terminal 1 to charge the battery and operate the vehicle's electrical system. Output
voltage is monitored at terminal 3 by the IC regulator. The charging circuit is protected by the 120A fusible link
[letter a , located in the fusible link box (battery)].
Ground is supplied
to generator terminal 5
through body ground F5, and
through the generator case to the cylinder block
With the ignition switch in the ON or START position, power is supplied
through 10A fuse [No. 3, located in the fuse block (J/B)]
to combination meter terminal 28 for the charge warning lamp.
The IC regulator controls ground to terminal 38 of the combination meter through terminal 2 of the generator.
When the ignition is turned on and power becomes available at terminal 2, this "wakes up" the regulator. The
regulator monitors charge output and grounds terminal 2 or leaves it open depending on charge output. With
power and ground supplied, the charge warning lamp will illuminate. When the generator is providing sufficient
voltage, the ground is opened and the charge warning lamp will go off.
If the charge warning lamp illuminates with the engine running, a malfunction is indicated.

Page 2703 of 2896

CHARGING SYSTEM
SC-29
C
D
E
F
G
H
I
J
L
MA
B
SC
Revision: June 20062007 Versa
DIAGNOSTIC PROCEDURE 1
Check Charge Warning Lamp Circuit
1. CHECK CHARGE WARNING LAMP CIRCUIT CONNECTION
Check to see if terminal 2 is clean and tight.
OK or NG
OK >> GO TO 2.
NG >> Repair terminal 2 connection. Confirm repair by performing complete Battery/Starting/Charging
system test.
2. CHECK CHARGE WARNING LAMP CIRCUIT
1. Disconnect generator connector F1.
2. Apply ground to generator connector F1 terminal 2 with the igni-
tion switch in the ON position.
OK or NG
OK >> GO TO SC-28, "WORK FLOW" .
NG >> Check the following.
10A fuse [No. 3, located in fuse block (J/B)]
CHARGE lamp
Harness for open or short between combination
meter and fuse
Harness for open or short between combination meter and generator CHARGE lamp should light up.
WKIA5577E

Page 2705 of 2896

CHARGING SYSTEM
SC-31
C
D
E
F
G
H
I
J
L
MA
B
SC
Revision: June 20062007 Versa
DIAGNOSTIC PROCEDURE 3
Check Voltage Regulator Circuit
1. CHECK VOLTAGE REGULATOR CIRCUIT CONNECTION
Check to see if terminal 3 is clean and tight.
OK or NG
OK >> GO TO 2.
NG >> Repair terminal 3 connection. Confirm repair by performing complete Battery/Starting/Charging
system test.
2. CHECK VOLTAGE REGULATOR CIRCUIT
Check voltage between generator connector F1 terminal 3 and
ground using a digital circuit tester.
OK or NG
OK >> GO TO 3.
NG >> Check the following.
10A fuse (No. 29, located in fuse and fusible link box)
Harness for open or short between generator and
fuse
3. CHECK VOLTAGE DROP ON VOLTAGE REGULATOR CIRCUIT
Check voltage between generator connector F1 terminal 3 and bat-
tery positive terminal using a digital circuit tester.
OK or NG
OK >> Replace the generator. Refer to SC-32, "Removal and
Installation" . Confirm repair by performing complete
Battery/Starting/Charging system test.
NG >> Check harness between the battery and the generator
for poor continuity. Battery voltage should exist.
WKIA5579E
With engine running
at idle and warm: Less than 0.2V
WKIA5580E