lock PEUGEOT BOXER 2015 Repair Manual

Page 268 of 276

266
dIAGnoSIS
SymptomElectricalHydraulic Verification / check
the hydraulic unit does


not operate. X
Power supply harness and relay.
X Control harness (control unit).
X Circuit breaker.
unit very noisy

, body
rises slowly. X
Pick-up strainer blocked or squashed at the bottom of the reservoir.
New unit very noisy,
body rises quickly. X
Pump alignment, change the unit.
the ram goes down on


its own. X
Return valve squashed or jammed.
the ram does not go


down. X
Yes, check the valve slider and bleed.
Refer to the "Servicing" section.
X No, check the return valve winding and electrical connections.
X No, replace the electrovalve.
X No, check the alignment of the ram.