protection Seat Ibiza 2020 Directive 2014/53/EU Bluetooth
Page 164 of 406
   
 
Page  54   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
M.3   TABLE: Protection circuits for batteries provided within the equipment  
N/A  
Is it possible to install the battery in a reverse polarity position? ......   :    
  
Equipment Specification   Charging  
Voltage (V)   Current (A)  
   
Manufacturer/type   Battery specification  
Non - rechargeable batteries   Rechargeable batteries  
Discharging 
current (A)   Unintentional 
charging 
current (A)   Charging   Discharging 
current (A)   Reverse 
charging 
current (A)  Voltage (V)   Current (A)  
             
Note: The tests of  M.3.2 are applicable only when above appropriate data is not available.   
Specified battery temperature ( o
C)   ................................ ...................   :      
Componen
t No.   Fault 
condition   Charge/ 
discharge mode   Test 
time   Temp. 
( o
C)   Current 
(A)   Voltage 
(V)   Observation  
               
Supplementary informat ion:  
Abbreviation: SC= short circuit; OC= open circuit NL= no chemical leakage; NS= no spillage of liquid; NE= 
no explosion; NF= no emission of flame or expulsion of molten metal.  
 
 
M.4.2   TABLE:  Charging  safeguards  for  equipment  containing  a  secondary  lit hium 
battery   N/A  
Maximum specified charging voltage (V)   ................................ .....   :    
  
Maximum specified charging current (A)    ................................ .....   :    
  
Highest specified charging temperature ( o
C)    ..............................   :      
Lowest specified charging temperature ( o
C)    ...............................   :      
Battery 
manufacturer/type   Operating 
and fault 
co ndition   Measurement   Observation  
Charging 
voltage (V)   Charging 
current (A)   Temp.   
( o
C)    
           
Supplementary information:  
Abbreviation: SC= short circuit; OC= open circuit; MSCV= maximum specified charging voltage; MSCC= 
maximum specified charging curre nt; HSCT= highest specified charging temperature; LSCT= lowest 
specified charging temperature   
Page 169 of 406
   
 
Page  59   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
  For special national conditions, see Annex ZB.  
1   Add   the following note:  
NOTE Z1  The use of certain substances in electrical and electronic 
equipment is restricted within the EU: see Directive 2011/65/EU.     P  
4.Z1   Add   the following new subclause after 4.9:  
To protect against excessive current, short - circuits and 
earth faults in circuits connected to an a.c.  mains , 
protective devices shall be included either as integral 
parts of the equipment or as parts of the building 
installation, subject to the following, a), b) and c):  
a) except as detailed in b) and c), protective devices 
necessary to comply with the requirements of B.3.1 and 
B.4 shall be included as parts of the equipment;  
b) for components in series with the mains   input to the 
equipment such as the supply cord, appliance coupler, 
r.f.i. filter and switch, short - circuit and earth fault 
protection may be provided by protective devices in the 
building installation;  
c) it is permitted for  pluggable equipment type B   or 
permanently connected equipment , to rely on 
dedicated overcurrent and short - circuit protection in the 
building installation, provided that the means of 
protection, e.g. fuses or circuit breakers, is fully 
specified in the installation instructions.  
If reli ance is placed on protection in the building 
installation, the installation instructions shall so state, 
except that for  pluggable equipment type A   the 
building installation shall be regarded as providing 
protection in accordance with the rating of the wal l 
socket outlet.     N/A  
5.4.2.3.2.4   Add   the following to the end of this subclause:  
The requirement for interconnection with  external 
circuit   is in addition given in EN 50491 - 3:2009.     N/A  
10.2.1   Add the following to  c)
  and  d)
  in table 39:  
For additional re quirements, see 10.5.1.     N/A   
Page 174 of 406
   
 
Page  64   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 5.5.6   Finland, Norway  and   Sweden  
To the end of the subclause the following is added:  
Resistors used as  basic safeguard   or bridging  basic 
insulation   in  class I pluggable equipment   type A  
shall comply with G.10. 1 and the test of G.10.2.     N/A  
5.6.1   Denmark  
Add   to the end of the subclause  
Due to many existing installations where the socket -
outlets can be protected with fuses with higher rating 
than the rating of the socket - outlets the protection for 
pluggable equi pment type A shall be an integral part of 
the equipment.  
Justification:  
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse.     N/A  
5.6.4.2.1   Ireland and United Kingdom  
After the indent for  pluggable equipment type A , the 
following is  added:  
–   the  protective current rating   is taken to be 13 A, this 
being the largest rating of fuse used in the  mains   plug.     N/A  
5.6.5.1   To the second paragraph the following is added:  
The range of conductor sizes of flexible cords to be 
accepted by termina ls for equipment with a rated 
current over 10 A and up to and including 13 A is:  
1,25 mm 2
  to 1,5 mm 2
  in cross - sectional area.     N/A  
5.7.5   Denmark  
To the end of the subclause the following is added:  
The installation instruction shall be affixed to the 
equip ment if the  protective conductor current  
exceeds the limits of 3,5 mA a.c. or 10 mA d.c.     N/A   
Page 176 of 406
   
 
Page  66   of  8 9   Report No. :  60404488 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 5.7.6.2   Denmark  
To the end of the subclause the following is added:  
The warning  (marking safeguard) for high touch current 
is required if the touch current or the protective current 
exceed the limits of 3,5 mA .     N/A  
B.3.1 and 
B.4   Ireland and United Kingdom  
The following is applicable:  
To protect against excessive currents and short - circuits 
in the primary circuit of  direct plug - in equipment , tests 
according to Annexes B.3.1 and B.4 shall be conducted 
using an external miniature circuit breaker complying 
with EN 60898 - 1, Type B, rated 32A. If the equipment 
does not pass these tests, s uitable protective devices 
shall be included as an integral part of the  direct plug -
in equipment , until the requirements of Annexes B.3.1 
and B.4 are met     N/A  
G.4.2   Denmark  
To the end of the subclause the following is added:  
Supply cords of single phase a ppliances having a rated 
current not exceeding 13 A shall be provided with a plug 
according to DS 60884 - 2 - D1:2011.  
CLASS I EQUIPMENT provided with socket - outlets with earth 
contacts or which are intended to be used in locations where 
protection against ind irect contact is required according to the 
wiring rules shall be provided with a plug in accordance with 
standard sheet DK 2 - 1a or DK 2 - 5a.  
If a single - phase equipment having a RATED CURRENT 
exceeding 13 A or if a poly - phase equipment is provided with 
a su pply cord with a plug, this plug shall be in accordance with 
the standard sheets DK 6 - 1a in DS 60884 - 2 - D1 or EN 60309 -
2.  
Mains socket outlets intended for providing power to 
Class II apparatus with a rated current of 2,5 A shall be 
in accordance DS 60884 - 2 - D1:2011 standard sheet 
DKA 1 - 4a.  
Other current rating socket outlets shall be in 
compliance with Standard Sheet DKA 1 - 3a or DKA 1 -
1c.  
Mains socket - outlets with earth shall be in compliance 
with DS 60884 - 2 - D1:2011 Standard Sheet DK 1 - 3a, DK 
1 - 1c, DK1 - 1d, D K 1 - 5a or DK 1 - 7a  
Justification:  
Heavy Current Regulations, Section 6c     N/A   
Page 180 of 406
   
 
Page  70   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 3.3.19.3  
  sound exposure,  E  
 
A - weighted sound pressure ( p ) squared and 
integrated over a stated period of   time,  T  
 
Note 1 to entry: The SI unit is Pa 2
  s.  
    N/A  
3.3.19.4  
  sound exposure level,  SEL  
 
logarithmic measure of sound exposure relative to a 
reference value,  E 0 , typically the 1 kHz  
threshold of hearing in humans.  
 
Note 1 to entry:  SEL  is measured as  A - weighted levels in dB.  
 
dB  
 
Note 2 to entry: See B.4 of EN 50332 - 3:2017 for additional 
information.     N/A  
3.3.19.5  
  digital signal level relative to full scale, dBFS  
 
levels reported in dBFS are always r.m.s. Full scale 
level, 0 dBFS, is the level of a  dc - free 997 -  
Hz sine wave whose undithered positive peak value 
is positive digital full scale, leaving the code  
corresponding to negative digital full scale unused  
 
Note 1 to entry: It is invalid to use dBFS for non - r.m.s. levels. 
Because the definition of   full scale is based on a sine wave, the 
level of signals with a crest factor lower than that of a sine wave 
may exceed 0 dBFS. In particular, square wave signals may 
reach +3,01 dBFS.     N/A  
2   Modification to Clause 10  
N/A  
10.6   Safeguards against acoustic   energy sources  
Replace 10.6 of IEC 62368 - 1 with the following:   N/A  
10.6.1.1   Introduction  
 
Safeguard  requirements for protection against long -
term exposure to excessive sound pressure  
levels from personal music players closely coupled 
to the ear are speci fied below. Requirements  
for earphones and headphones intended for use 
with personal music players are also covered.  
A personal music player is a portable equipment 
intended for use by an  ordinary person , that:  
 
  –   is designed to allow the user to listen t o audio or 
audiovisual content / material; and     N/A     
Page 181 of 406
   
 
Page  71   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
    –   uses a listening device, such as headphones or 
earphones that can be worn in or on or  
around the ears; and  
  –   has a player that can be body worn (of a size 
suitable to be carried in a clothing pocket) and  
i s intended for the user to walk around with while in 
continuous use (for example, on a street,  
in a subway, at an airport, etc.).  
 
EXAMPLES Portable CD players, MP3 audio players, mobile 
phones with MP3 type features, PDAs or similar equipment.  
 
Personal m usic players shall comply with the 
requirements of either 10.6.2 or 10.6.3.  
 
NOTE 1 Protection against acoustic energy sources from telecom 
applications is referenced to ITU - T P.360.  
 
NOTE 2 It is the intention of the Committee to allow the 
alternative met hods for now, but to only use the dose  
measurement method as given in 10.6.5 in future. Therefore, 
manufacturers are encouraged to implement 10.6.5 as soon as 
possible.  
 
Listening devices sold separately shall comply with 
the requirements of 10.6.6.  
These  requirements are valid for music or video 
mode only.  
The requirements do not apply to:  
–   professional equipment;  
 
NOTE 3 Professional equipment is equipment sold through 
special sales channels. All products sold through  
normal electronics stores are consid ered not to be professional 
equipment.  
 
–   hearing aid equipment and other devices for 
assistive listening;  
–   the following type of analogue personal music 
players:  
•  long distance radio receiver (for example, a 
multiband radio receiver or world band radio  
receiver, an AM radio receiver), and  
•  cassette player/recorder;  
 
NOTE 4 This exemption has been allowed because this 
technology is falling out of use and it is expected that  
within a few years it will no longer exist. This exemption will not 
be extended t o other technologies.  
 
–   a player while connected to an external amplifier 
that does not allow the user to walk around  
while in use.  
 
For equipment that is clearly designed or intended 
primarily for use by children, the limits of the  
relevant toy standards   may apply.  
 
The relevant requirements are given in    
Page 184 of 406
   
 
Page  74   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  known by other means such as setting or automatic 
detection, the  L Aeq , T  acoustic output shall be  ≤  80 dB 
when playing the fixed “programme simulation 
noise” described in EN 50332 - 1.  
–   for equipment provided with a standardized 
connector (for example, a 3,5 phone jack) that 
allows connection to a listening device for general 
use, the unweighted r.m.s. output voltage shall be  ≤ 
15 mV (analogue interface) or  - 30 dBFS (digital 
interface) w hen playing the fixed “programme 
simulation noise” described in EN 50332 - 1.  
10.6.3.3   RS2 limits (new)  
 
RS2 is a class 2 acoustic energy source that does 
not exceed the following:  
–   for equipment provided as a package (player with 
its listening device ), and with a proprietary connector 
between the player and its listening device, or where 
the combination of player and listening device is 
known by other means such as setting or automatic 
detection, the weekly sound exposure level, as 
described in EN 503 32 - 3, shall be  ≤  80 dB when 
playing the fixed "programme simulation noise" 
described in EN 50332 - 1.  
–   for equipment provided with a standardized 
connector (for example, a 3,5 phone jack) that 
allows connection to a listening device for general 
use, the unw eighted r.m.s. output level, integrated 
over one week, as described in EN50332 - 3, shall be 
≤  15 mV (analogue interface) or  - 30 dBFS (digital 
interface) when playing the fixed “programme 
simulation noise” described in EN 50332 - 1.     N/A  
10.6.4  
Requirements f or maximum sound exposure  
N/A  
10.6.4.1   Measurement methods  
 
All volume controls shall be turned to maximum 
during tests.  
 
Measurements shall be made in accordance with EN 
50332 - 1 or EN 50332 - 2 as applicable.     N/A  
10.6.4.2   Protection of persons  
 
Except as   given below, protection requirements for 
parts  accessible  to  ordinary persons ,  instructed 
persons  and  skilled persons  are given in 4.3.  
 
NOTE 1 Volume control is not considered a  safeguard.  
 
Between RS2 and an  ordinary person , the  basic 
safeguard  may be r eplaced by an  instructional 
safeguard  in accordance with Clause F.5, except 
that the  instructional safeguard  shall be placed on 
the equipment, or on the packaging, or in the 
instruction manual.     N/A   
Page 189 of 406
   
 
Page  79   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
5  
Modification to 4.Z1  
N /A  
4.Z1   Add  the following new subclause after 4.9:  
 
To protect against excessive current, short - circuits 
and earth faults in circuits connected to an a.c. 
mains , protective devices shall be included either as 
integral parts of the equipment or as parts of   the 
building installation, subject to the following, a), b) 
and c):  
a) except as detailed in b) and c), protective devices 
necessary to comply with the requirements of B.3.1 
and B.4 shall be included as parts of the equipment;  
b) for components in series  with the mains input to 
the equipment such as the supply cord, appliance 
coupler, r.f.i. filter and switch, short - circuit and earth 
fault protection may be provided by protective 
devices in the building installation;  
c) it is permitted for  pluggable equipm ent type B  or 
permanently connected equipment , to rely on 
dedicated overcurrent and short - circuit protection in 
the building installation, provided that the means of 
protection, e.g. fuses or circuit breakers, is fully 
specified in the installation instruc tions.  
 
If reliance is placed on protection in the building 
installation, the installation instructions shall so state, 
except that for  pluggable equipment type A  the 
building installation shall be regarded as providing 
protection in accordance with the ra ting of the wall 
socket outlet.     N/A  
6  
Modification to 5.4.2.3.2.4  
N/A  
5.4.2.3.2.4   Add  the following to the end of this subclause:  
 
The requirement for interconnection with  external 
circuit   is in addition given in EN 50491 - 3:2009.     N/A  
7  
Modification to   10.2.1  
N/A  
10.2.1  
Add the following to  c)
  and  d)
  in table 39:  
 
For additional requirements, see 10.5.1.     N/A   
Page 193 of 406
   
 
Page  83   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TRF No.  IEC62368_1 C    
   
A   capacitor classified Y3 according to EN 60384 -
14:2005, may bridge this insulation under  
the following conditions:  
 
•    the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by EN 
60384 - 14, which in addition to the Y3 tes ting, is 
tested with an impulse test of 2,5 kV defined in 
5.4.11;  
 
•   the additional testing shall be performed on all the 
test specimens as described in EN 60384 - 14;  
 
the impulse test of 2,5 kV is to be performed before 
the endurance test in EN 60384 - 14,   in the sequence 
of tests as described in EN 60384 - 14.  
5.5.2.1   Norway  
 
After the 3rd paragraph the following is added:  
 
Due to the IT power system used, capacitors are 
required to be rated for the applicable line - to - line 
voltage (230 V).     N/A  
5.5.6   Finland, Norway  and  Sweden  
 
To the end of the subclause the following is added:  
 
Resistors used as  basic safeguard  or bridging 
basic insulation  in  class I pluggable equipment 
type A  shall comply with G.10.1 and the test of 
G.10.2.     N/A  
5.6.1   Denmark  
 
Add  to the end of the subclause  
Due to many existing installations where the socket -
outlets can be protected with fuses  
with higher rating than the rating of the socket -
outlets the protection for pluggable  
equipment type A shall be an integral part of the 
equi pment.  
Justification:  
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse.     N/A  
5.6.4.2.1   Ireland and United Kingdom  
 
After the indent for  pluggable equipment type A , 
the following is added:  
–   the  protective current rating  is taken t o be 13 A, 
this being the largest rating of fuse used in the 
mains  plug.     N/A   
Page 196 of 406
   
 
Page  86   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TRF No.  IEC62368_1 C    
 B.3.1 and  
B.4   Ireland and United Kingdom  
 
The following is applicable:  
 
To protect against exce ssive currents and short -
circuits in the primary circuit of  direct plug - in 
equipment , tests according to Annexes B.3.1 and 
B.4 shall be conducted using an external miniature 
circuit breaker complying with EN 60898 - 1, Type B, 
rated 32A. If the equipment doe s not pass these 
tests, suitable protective devices shall be included 
as an integral part of the  direct plug - in equipment , 
until the requirements of Annexes B.3.1 and B.4 are 
met     N/A  
G.4.2   Denmark  
 
To the end of the subclause the following is added:  
 
Sup ply cords of single phase appliances having a 
rated current not exceeding 13 A shall be provided 
with a plug according to DS 60884 - 2 - D1:2011.  
 
CLASS I EQUIPMENT provided with socket - outlets 
with earth contacts or which are intended to be used 
in locations  where protection against indirect contact 
is required according to the wiring rules shall be 
provided with a plug in accordance with standard 
sheet DK 2 - 1a or DK 2 - 5a.  
 
If a single - phase equipment having a RATED 
CURRENT exceeding 13 A or if a polyphase  
equ ipment is provided with a supply cord with a 
plug, this plug shall be in accordance with the 
standard sheets DK 6 - 1a in DS 60884 - 2 - D1 or EN 
60309 - 2.  
 
Mains socket outlets intended for providing power to 
Class II apparatus with a rated current of 2,5 A shal l 
be in accordance DS 60884 - 2 - D1:2011 standard 
sheet DKA 1 - 4a.  
 
Other current rating socket outlets shall be in 
compliance with Standard Sheet DKA 1 - 3a  
or DKA 1 - 1c.  
 
Mains socket - outlets with earth shall be in 
compliance with DS 60884 - 2 - D1:2011  
Standard Sh eet DK 1 - 3a, DK 1 - 1c, DK1 - 1d, DK 1 - 5a 
or DK 1 - 7a  
 
Justification:  
Heavy Current Regulations, Section 6c     N/A