TOYOTA PRIUS PRIME 2019 Owners Manual (in English)

Page 151 of 792

PRIUS PRIME_OM_OM47D13U_(U)
1512-2. Charging
2
Plug-in hybrid system
WARNING
■If the error warning indicator on the CCID (Charging Circuit In terrupt-
ing Device) illuminates or flashes during charging
There may be an electrical leakage in the power source path, or there may
be a malfunction in the charging cable or CCID (Charging Circuit Interrupt-
ing Device). Refer to P. 116 and follow the correction procedur e. If the error
warning indicator does not turn off even after performing the c orrection pro-
cedure, immediately stop charging, remove the charging cable an d contact
your Toyota dealer. Continuing to charge the vehicle in that co ndition may
lead to unforeseen accidents or serious injury.
■ After charging
Remove the plug if it will not be used for a long time.
Dirt and dust may accumulate plug or outlet, which could cause a malfunc-
tion or fire, possibly leading to death or serious injury.
■ Charging equipment
There is charging equipment under the rear seats. Make sure to observe
the following precautions regarding the charging equipment. Fai lure to
observe these precautions may result in death or serious injury such as
burns and electric shocks.
● The charging equipment is hot during charging. Do not touch the charging
equipment, as doing so may result in burns.
● Do not disassemble, repair or modify the charging equipment.
When the charging equipment needs to be repaired, consult your To y o t a
dealer.

Page 152 of 792

152
PRIUS PRIME_OM_OM47D13U_(U)
2-2. Charging
NOTICE
■When use the charging cable and related parts
To prevent damage to the charging cable and related parts, observe the fol-
lowing precautions.
● When interrupting or canceling charging, remove the charging co nnector
before removing the plug.
● Vehicles with smart lid & connector locking system: When removi ng the
charging cable, check that the charging connector is unlocked.
● Do not forcefully pull the connector cap and charging inlet cap .
● Do not apply a vibration to the charging connector while chargi ng.
Charging may be stopped.
● Do not insert anything but the charging connector.
● When inserting the plug into or removing the plug from the outlet, make
sure to hold the body of the plug.
● Do not damage the charging inlet cap with a sharp object.
● Do not forcefully pull the charging cable that is caught or entangled.
If the cable is entangled, disentangle it before using.
● When charging from the external device, use the charging cable equipped
with the vehicle.
■ When charging
Do not insert the plug into the charging inlet.
The charging inlet may be damaged.
■ After charging
● After disconnecting the charging connector from the charging in let, make
sure to put on the charging inlet cap and close the charging port lid.
If the charging inlet cap is not put on, water or foreign objects may enter
the charging inlet, which could lead to vehicle damage.
• Vehicles without smart lid & connector locking system: The cha rging
port lid does not have a lock. Take care not to press and open the door
accidentally.
• Vehicles with smart lid & connector locking system: If the charging port lid is not locked, take care as it may open if unintentionally touched.
● After removing the plug from the outlet, keep it in a safe plac e free from
moisture and dust.
The charging cable or plug may be damaged if the cable is stepp ed on or
ridden over by the vehicle.

Page 153 of 792

PRIUS PRIME_OM_OM47D13U_(U)
1532-2. Charging
2
Plug-in hybrid system
NOTICE
■Using private power generator
Do not use private power generators as a power source for charg ing.
Doing so may make charging unstable, the voltage may be insuffi cient, and
the error warning indicator on the CCID (Charging Circuit Inter rupting
Device) of the charging cable may flash.
■ Usable temperature range
● Do not charge if the outside temperature is -22 F (-30 C) or below, as it is
likely that charging will take longer, and equipment related to charging will
be damaged.
● Do not leave the vehicle or the charging cable in areas where t he outside
temperature is lower than -40 F (-40 C). The vehicle or charging cable will
probably be damaged.
■ Charging equipment
Due to the environment in which the power equipment is located, charging
may be unstable due to noise, the voltage may be insufficient, and the error
warning indicator on the CCID (Charging Circuit Interrupting De vice) of the
charging cable may flash.

Page 154 of 792

154
PRIUS PRIME_OM_OM47D13U_(U)
2-2. Charging
Using the charging timer function
When registering the charge schedule, the following settings ca n be
changed.
■Select the charging mode
One of the two following c harging modes can be selected.
*: There might be a slight error in the timing when charging star ts due to the
state of the hybrid battery (traction battery).

Repeated setting
The periodic timer charging can be set by selecting your desire d
day of the week.
■Air conditioning-linked s etting (“Climate Prep”)
When the charging mode is set to “Departure”, the vehicle air c ondi-
tioning system ( P. 496, 507) can be set to automatically operate*
according to the set time.
By adjusting the cabin temperature in advance, passengers can e njoy a
pleasant interior immediately after entering the vehicle.
*: Operation starts approximately 10 minutes before the set depar ture time.
Charging can be carried out at the desired time by registering
the charge schedule. Also, it is possible to set the timer to one’s
preferences, such as having charging complete by a certain
departure time or be carried out at the same time on certain
days.
Settings of the char ging timer function
Charging modeOperation description
“Start”Starts charging at the set time and finishes charging
when fully charged.
*
“Departure”
Starts charging to finish at the set time.
When this setting is selected, the air conditioning-
linked function can be used.

Page 155 of 792

PRIUS PRIME_OM_OM47D13U_(U)
1552-2. Charging
2
Plug-in hybrid system
■Turning “Charge Now” on and off
If even one charge schedule is registered, charging does not start
until the set time, even if the charging cable is connected to the
vehicle. To start charging immediately without changing the cha rge
schedule setting, turn “Charge Now” on to temporarily cancel th e
charge schedule and enable charging immediate after connecting
the charging cable.
■Changing “Next Charging Event”*1
It is possible to temporarily set the time of the next schedule d
charge without changing the r egistered repeated setting.
*2
*1: The “Next Charging Event” refers to the closest charge schedul e from the
current time among the registered charge schedules. Timer charging is
performed based on the “Next Charging Event”.
*2: When “Next Charging Event” is changed, the current charge sche dule will
be temporarily ignored and charging will not be carried out unt il the time
specified by “Next Charging Event”. (For example, when “Next Ch arging
Event” is set for 2 days later, even if items are registered on the charge
schedule, charging will not be carried out until the time speci fied by “Next
Charging Event”.)
The charge schedule can be reg-
istered on the multi-information
display or 11.6-inch display (if
equipped).
● Multi-information display opera-
tion: P. 158
● 11.6-inch display operation (if
equipped): P. 167
Registering the charge schedule

Page 156 of 792

156
PRIUS PRIME_OM_OM47D13U_(U)
2-2. Charging
■Timer settings
A maximum of 15 charge schedules can be registered.
■ To make sure that the charging timer function operates correctl y
Check the following items.
● Adjust the clock to the correct time ( P. 193)
● The calendar is set to the correct date ( P. 194)
● Check that the power switch is turned off
● After registering the charge schedule, connect the charging cable
The charging start time is determined based on the charge sched ule at the
time that the charging cable was connected.
● After connecting the charging cable, check that the charging indicator
flashes ( P. 112)
● Do not use an outlet that has a power cut off function (including a timer func-
tion)
Use an outlet that constantly supplies electricity. For outlets where the
power is cut off due to a timer function, etc., charging may no t be carried
out according to plan if the power is cut off during the set ti me.
■ When the charging cable remains connected to the vehicle
Even if multiple consecutive charge schedules are registered, t he next
charge will not be carried out according to the timer until the charging cable is
removed and reconnected after charging completes. Also, when th e hybrid
battery (traction battery) is fully charged, charging according to the timer will
not be carried out.
■ “Climate Prep”
●When the air conditioning-linked setting is turned on, the air conditioning
operates until the set departure time. Therefore, the air condi tioning will con-
sume electricity and charging may not complete by the set depar ture time.
● If the hybrid battery (traction battery) is fully charged, char ging will not be
carried out, even if the charge schedule is set. However, if “Climate Prep” is
turned on, the air conditioning will operate only once when it nears the time
set in “Departure”. If this occurs, the air conditioning will c onsume electricity
and the remaining charge of the hybrid battery (traction batter y) when
departing may be decreased.
■ Smartphone-linked operation (vehicles with 11.6-inch display)
After applying to Entune, it is possible to use the smartphone application to
change charging timer settings.
For details about Entune, refer to http://www.toyota.com/entune/.

Page 157 of 792

PRIUS PRIME_OM_OM47D13U_(U)
1572-2. Charging
2
Plug-in hybrid system
■When timer settings are ignored
When the following operations are performed while the charging timer is on
standby, timer charging is temporarily canceled and charging is started imme-
diately.
● When the Remote Air Conditioning System ( P. 518) is operated
● When turning “Charge Now” on ( P. 163, 172)
● When an operation that temporarily cancel charging using the timer
(P. 146)
■ Effects of outside temperature
When the charging mode is set to “Departure”, timer settings ma y be ignored
due to the outside temperature and charging may start immediate ly.
■ “Traction Battery Cooler” ( P. 133)
When charging is carried out using the timer, the hybrid battery (traction bat-
tery) cooling function may operate according to the temperature of the hybrid
battery (traction battery).
● When the charging mode is set to “Start”, cooling starts at the set charging
start time.
● When the charging mode is set to “Departure”, cooling starts ap proximately
30 minutes before the charging start time. However, if there is no time to fin-
ish charging by the timer setting, the hybrid battery (traction battery) cooling
time may be shortened and “Traction Battery Cooler” may not ope rate.

Page 158 of 792

158
PRIUS PRIME_OM_OM47D13U_(U)
2-2. Charging
When operating timer settings, use the charging timer switch and
meter control switches.
Charging timer switch
Meter control switches
( P. 189)
Multi-information display
■Registering the charge schedule Press the charging timer switch.
The “Charge Schedule” screen will display on the multi-informat ion dis-
play.
Press or of the
meter control switches to
select “Scheduled Events”,
and then press .
The “Scheduled Events” screen
will display.
Press or of the
meter control switches to
select “+”, and then press
.
The “Edit Charging Event”
screen will display.
Setting operations on multi-information display
1
2
3
1
2
3

Page 159 of 792

PRIUS PRIME_OM_OM47D13U_(U)
1592-2. Charging
2
Plug-in hybrid system
Press or of the
meter control switches to
select the charging mode/
time settings row, and then
press .
The charging mode/time set-
tings screen will display.
The clock display (12-hour dis-
play/24-hour display) changes
according to the clock settings.
(P. 193)
Press or of the
meter control switches to
select the item to change
with the cursor, and then
press or to change
the setting.
Set the desired charging mode
and charging start (or departure)
time.
When the charging mode is “Start” , this sets the charging start time.
When it is “Departure”, this sets the charging end time.
After changing the settings to the desired settings, press to return to
the previous screen.
To activate the repeated set-
ting, press or of the
meter control switches to
select “Repeat”, and then
press .
A screen where the repeated
day can be selected will display.
4
5
6

Page 160 of 792

160
PRIUS PRIME_OM_OM47D13U_(U)
2-2. Charging
Press or of the
meter control switches to
select the desired day to acti-
vate for the repeated setting,
and then press .
Each time is pressed, the
repeated setting switches
between on and off.
When set to on, the selected day is highlighted and the charging timer is
repeated on that day. It is possible to set more than one day to on.
If no days are set to on, charging is only carried out once according to
the timer for the next 24 hours.
After changing the settings to the desired settings, press to return to
the previous screen.
When the charging mode is
set to “Departure”, set the
“Climate Prep” ( P. 1 5 4 ) t o
on or off.
To turn the function on and oper-
ate the air conditioning, press
or of the meter control
switches to select “Climate
Prep”, and then press .
Each time is pressed, the function switches between on and off .
After setting operations are
complete, press .
A screen where the settings can
be saved will display.
Press or of the meter
control switches to select “Yes”,
and then press to save the
settings.
If you wish to change the settings, select “No” and perform the setting
procedure from step again.
After setting operations are complete, when the charging cable is con-
nected to the vehicle, charging will be carried out according to the
charging timer settings.
7
8
9
3

Page:   < prev 1-10 ... 111-120 121-130 131-140 141-150 151-160 161-170 171-180 181-190 191-200 ... 800 next >