lock DACIA SOLENZA 2004 Repair Manual
[x] Cancel search | Manufacturer: DACIA, Model Year: 2004, Model line: SOLENZA, Model: DACIA SOLENZA 2004Pages: 891, PDF Size: 14.84 MB
Page 555 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 12
Procedures
A. E.C.U. DECODER REPLACEMENT PROCEDURE AND
ANTI STARTING CODE MEMORISING
The new E.C.U. decoder is always not coded. After its mounting on the vehicle it is necessary
that this one is memorising the anti starting code in order to be operational.
REMARK:
If only the E.C.U. decoder i s replaced, there i s no need of an i ntervention to t he
E.C.U. injection (injection computer), which will keep the old anti starting code.
AT T E N T I ON!
After the E.C.U. de coder memorised the anti starting c ode, this code cannot be erased
or replaced with another one. In order t o perform this procedure, one of the keys of t he ve hicle and the CLIP tester are
needed.
Proceed as follows:
1. Connect the CLIP tester to the diagnostic socket and to the battery (or the lighter socket)
of the vehicle. 2. Read the configuration of the old E.C.U. decoder in the following way, before dismounting
it from the vehicle:
- select the type “B41”
- enter the menu “ COMPUTER TEST” then select “ ANTI STARTING”
- access “COMMAND MODE” then “CONFIGURATIONS READING”
- note the configurations found : petrol, programming with 1 or 2 keys, ceiling delayed
light, the type of the doors’ blocking switch (CPE), etc.;
3. Return to the menu “COMPUTER TEST”
4. Remove the old E .C.U. decoder and replace it with a new one, the contact being off.
5. Enter the menu “ANTI STARTING”, then select “ STATE LIST”. If the E.C.U. decoder is
new, you must find the following states:
18G FIRST CYCLE MEMORISING………………….......………… PASSIVE
19G NOT PERFORMED KEY PROGRAMMING ………..……….. ACTIVE
19D UNBLOCKED KEY PROGRAMMING ……………….………ACTIVE
OBSERVAT ION:
If the states 19G and 19D are not “ACTIVE” this means the E.C.U. decoder has
b een already used, so it isn’t new and cannot memorise another anti starting code.
6. Access t he menu “COMMAND MODE” and then “CONFIGURATION”, where you
will c onfigure t he new E .C.U. decoder in the same way as the old one : petrol, 1 ke y, ceiling
delayed light, impulsion doors blocking switch, etc. selecting one by one these configurations,
which you’ll validate with “CLICK” on the blue button on right top of the screen.
vnx.su
Page 556 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 13
Procedures
1. Return to “COMPUTER TEST”
2. Set the contact on for 2 seconds in “ M” position, without start ing the engine. The anti
starting indicator will begin to blink rapidly.
3. Access the menu “ STATE LIST”, where the following states must exist:
9D RECEIVED KEY CODE ………………………………......…… ACTIVE
19G NOT PERFORMED KEY PROGRAMMING …………….…… PASSIVE
10. Take the c ontact off. In the menu “COMMAND MODE” select “ACTUATORS”, then
validate “ FINISHED CALIBRATION” launching the command on the blue rectangle situated
on the right top of the screen. The message “COMMAND IN PROGRESS” will appear, followed
by “ FINISHED COMMAND”. 11 . The anti starting indicator will blink rarely.
12. Return to the “STATE LIST”, which now, must be like that: 18G FIRST CYCLE MEMORISING…………………………….....…ACTIVE
19G NOT PERFORMED KEY PROGRAMMING…………….……..PASSIVE
19D UNBLOCKED KEY PROGRAMMING …………………..…… PASSIVE
13. Set the contact i n “M” position for 2-3 seconds in order t o send the code t o the E.C.U.
injection. The anti starting indicator must light for 3 seconds, then turn off.
14. Take off the contact. After 10 seconds, the anti starting indicator will blink rarely.
15. Check the engine starting with both keys, and then take the contact off.
16. Check in the menu “ STATE LIST ” if the state 10G “ANTI STARTING” is “ ACTIVE”.
Perform the synchronisation of the TRF remote control with the decoder (with 1or 2 keys).
OBSERVAT ION:
With the CLIP tester, a starting interdiction may be simulated, proceeding as follows:
- take the contact off; wait for 10 seconds, then the anti starting indicator will blink;
- in the menu, “COMMAND MODE” access “ ACTUATORS” then validate “ FORCED
PROTECTION MODE” launching the command from the blue button situated on the ri ght
topside of the screen. “COMMAND IN PROGRESS” will be displayed and then “FINISHED
COMMAND”; - in t he m enu “ STATE LIST” search for the state 10G ”ANTI START ING”, which
must be “ ACTIVE”; - set the contact on “M” position; the anti starting indicator will blink rapidly, and the
engine starting is impossible;
- remove the key from the contact and check then the engine starting with both keys, so
the procedure is finished.
vnx.su
Page 557 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 14
Procedures
RE M ARK:
For the RF remote control synchronisation, after the replacement of an E.C.U. decoder,
the sync hron is ation proced ure must be per formed taking i nto account the foll owing
situations : - fo r one RF remote control, perform the “ SIMPLE SYNCHRONISED
PROCED URE ”;
- for the second RF remote co ntrol per form the “SPE CI FI C SYNCHRONI SED
PROCED URE ”.
B. KIT REPLACEMENT PROCEDURE
(E.C.U. decoder plus 2 key he ads)
In case of one kit replacement perform the following steps:
- memorising the anti starting code by the E.C.U. decoder;
- memorising of the new anti starting code by the injection computer; it is necessary the
repairing code (found out based on the old ke y heads code) and t he CLIP tester.
Perform the actions in the following sequence:
1. Mount the metal insertions of the old keys to the new key heads.
2. Inform by phone at ”Client Voice” (phone no 0248 500 000), the vehicle chassis series and
the key heads code, written on the vehicle invoice, in order to get the repairing code.
3. Connect the CLIP tester t o the diagnostic socket and to the battery (or to the lighter
s ocket) of the vehicle. Read the configuration of the old E.C.U. decoder before dismounting it
off the vehicle, as follows:
- select vehicle type “B41”;
- enter the menu “ COMPUTER TEST” then select “ ANTI STARTING”;
- access “COMMAND MODE” then “READ CONFIGURATIONS”;
- note the configuration s : petrol/diesel, programming with 1 or 2 keys, ceiling delayed light,
the type of the doors’ blocking switch (CPE), etc.
4. Return to the menu “ANTI START ING”.
5. Dismount the old E.C.U. decoder and replace it with a new one, the contact being off.
6. Check the configuration of the new E.C.U. decoder selecting “ STAT E LIST”; here you
must find the following states: 18G FIRST KEY MEMORISING……………………………........… PASSIVE
19G NOT PERFORMED KEY PROGRAMMING ………………..... ACTIVE
19D UNBLOCKED KEY PROGRAMMING ……………………..... ACTIVE
REMARK:
If the state 19G and 19D are not “ACTIVE” this means the E.C.U. decoder isn’t a
ne w one and cannot memorise another anti starting code.
vnx.su
Page 558 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 15
Procedures
7. Set the contact i n “M” position with one of the ke ys (without start ing the engine), for
about 2 seconds and then check the following states, which must be:
9D RECEIVED KEY CODE ……………………………….....…..... ACTIVE
19G NOT PERFORMED KEY PROGRAMMING ………….........… ACTIVE
8. Set the contact with the second key (without starting t he engine) for about 2 seconds.
Check then the following states:
-case (a)- the second key belongs to the vehicle;
9D RECEIVED KEY CODE ……………………………………..… ACTIVE
19G NOT PERFORMED KEY PROGRAMMING …………….....… PASSIVE
- case (b)- t he second key doe s not belong to t he vehicle or the first ke y was used once
again;
9D RECEIVED KEY CODE ……………………………………..… PASSIVE
19G NOT PERFORMED KEY PROGRAMMING ………….....…… ACTIVE
9. The anti starting indicator blinks rapidly.
10. Take off the contact. In the menu “ COMMAND MODE” select “ACTUATORS” and
validate “ FINISHED CALIBRATION” launching the command on the blue rectangle situated
on the right top of the screen. The message “COMMAND IN PROGRESS” will appear,
followed by “ FINISHED COMMAND”. 11 . The anti starting indicator will blink rarely.
12. Return to the “STATE L IST”, which now must be as follows: 18G FIRST KEY MEMORISING…………………………….........… ACTIVE
19G NOT PERFORMED KEY PROGRAMMING……………...……PASSIVE
19D UNBLOCKED KEY PROGRAMMING ………………...…...…PASSIVE
13. In the menu “COMMAND MODE” select “ ACTUATORS”. Select the command “
FORCED PROTECTION MODE” launching the command from the blue button situated on
the ri ght topside of the screen. The display will show “COMMAND IN PROGRESS” and
then “FINISHED COMMAND”.
Return to the “STATE LIST “ and check t he state: 9GFORCED PROTECTION MODE ………………………....…… ACTIVE
14. Set the contact on “M” position. The anti starting indicator will start to blink ra pidly.
Check in the “ STATE LIST” if the state “ANTI STARTING” is “ACTIVE”.
15. In the menu “COMMAND MODE” a ccess “ACTUATORS”, then select the command
“ MANUAL CODE INTRODUCTION”. Type t he four fi gures of the repairi ng code, t hen
validate with the key “ENTER”. On the screen the message “COMMAND IN PROGRESS”
w ill appear and then “FINISHED COMMAND”.
16. Set the contact off and then set again the contact on, without starting the engine, in order
to send the new anti starting code to the injection computer. The anti starting indicator will light
for 3 seconds, and then it will turn off.
vnx.su
Page 560 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 17
Procedures
D. SIMPLE SYNCHRONISED PROCEDURE
This procedure allows the synchronisation of a RF remote control with E.C.U. decoder and
is to be applied in the following situations: -the RF remote control c ode is no longer in the range of the E .C.U. decoder reception,
because of blind consecutive pushing over a 1000 time on the RF remote control button.;
- the replacement of the E .C.U. decoder with a new one;
- the replacement of the RF remote control if the E.C.U. decoder is new (E.C.U. decoder
replacement plus a RF key.);
The following operations will be performed: -take off the contact;
- push and maintain like that for about 5 seconds, the doors locking switch located on the
dashboard ; the doors actuators are performing a closing/opening course;
- during the next 10 seconds, confirmed by the permanent lightening of the anti starting
system indicator, push twice the RF remote control button; the doors actuators are performing a
closing/opening course;
-the procedure of synchronisation is finished; check the doors blocking/ unlocking by
pushing the RF remote control.
OBSERVAT ION:
During those 10 seconds you can visualise by means of the CLIP tester t he state 17G
“PROGRAMMING OR TIR/TRF RESYNCHRONISATION” which must be ACTIVE.
E. SPECIFIC SYNCHRONISED PROCEDURE
This procedure is used for the synchronisation of the second RF key with E.C.U. decoder
and will be performed as follows:
-connect the CLIP tester to the diagnostic socket and the battery (or the lighter socket)
of the vehicle;
- select the vehicle type “B41”;
- select the menu “ COMPUTERS TEST” then “ ANTI STARTING”;
- enter the menu “COMMAND MODE” and select “CONFIGURATION”;
- validate the command “ PROGRAMMI NG THE SECOND TIR / TRF KEY” launching
the command from the blue button situated on the right top of the screen; the doors actuators are
performing a closing/opening course. - during the next 10 seconds, confirmed by the permanent lightening of the anti starting
system, push twice t he RF remote control button; the doors will block and then unlock and the
anti starting indicator will turn off. The second remote control is now synchronised. Check the
blocking/ unlocking by pushing the RF remote control.
vnx.su
Page 563 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 20
Diag nostic
3. FAILURE : DOORS BLOCKING SWITCH
Remove the memorised failure by means of the CLIP tester.
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
Check the isolation related to the m ass of the
wir ing between the E.C.U. decoder doors’
locking switch B2 pin pole 1
B5 pin pole 5
Is there a correct isolation?
Repair the electric wiring.No
Replace t he doors’ locking switch.
Ye s
RECOMMENDATION Check if the switch does not remain permanently pressed due to a
mechanical blocking.
vnx.su
Page 566 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 23
Diag nostic
6. STATE 11G: ACTIVATE THE RF REMOTE CONTROL/ RECEIVED RF SIGNAL
IN DICATION
If the 17D state is PASSIVE, do not apply the next diagnostic
because the E .C.U. decoder is unused (new).
RECOMMENDATION Perform first the remote control synchronisation.
Do not access the next diagnostic if the state 11G remains
PA SSIVE when activating the RF remote c ontrol at the blocking
and unlocking of the doors.
Check the blocking and unlocking of the doors using the second RF remote control. If this
is one is operating, then the battery of the first RF remote control must be replaced.
Check the presence of +12 V(+DC) at the pin1 of the anti starting bushing.
Is there +12V ?
Pe rform using the CLIP tester, the impulse de tection test at the pin 1 of the anti
starting bushing, when using the RF remote control.
Are any impulses when using the remote control ?
YES Replace the E .C.U. decoder.
NO Replace the anti starting bushing.YES
Check the isolation related to the mass of the electric wiring between:
E.C.U. decoder Pin B1 pol e 1 anti start ing bushi ng Pin B2 pole 1 door locking switch
Pin B5 pole 5
Isolation against mass is good?
YES Fix the electric wiring.
NO Replace the E.C.U. decoder
.
NO
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
vnx.su
Page 567 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 24
Diag nostic
7. 11D STATE: OPERATE THE RF REMOTE CONTROL / GOOD RF SIGNAL
INDICATION
Do not access the following diagnostic unless the state 11D
RECOMMENDATION becomes ACTIVE when operating the RF remote control.
Check if the keys belong to the vehicle in question.
There is a desynchronising between the code of the RF remote control and the E.C.U. decoder
if at the activation of the remote control, the 111D state remains PASSIVE a nd the state 11G
becomes ACTIVE for 3 seconds, then becomes PASSIVE. The blocking / unlocking of the
doors is not possible in this case.
Apply the corresponding procedure of resynchronisation (for one or 2 keys).
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
vnx.su
Page 568 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 25
Diag nostic
8.14G STATE : DOORS BLOCKING/ UNLOCKING
RECOMMENDATION The state 10G (anti starting) must be ACTIVE .
Check the continuity and the isolation related to the +12 V and to the mass of the electric
wiring on the line E.C.U. decoder
Pin B2 pole 1 door locking switch.
Pin B5 pole 5
Fix the electric wiring if necessary or replace the switch.
If the incident persists, replace the E.C.U. decoder.
vnx.su
Page 572 of 891

82
ACCOUSTIC WARNING - ANTI STARTING
82 - 29
Diag nostic
ALP3. THE ANTI STARTING INDICATOR REMAINS PERMANENTLY LIGHTED
( even when the contact is taken off) OR IT REMAINS PERMANENTLY SWITCHED
OFF
RECOMMENDATION Check if the “Procedure E.C.U. decoder replacement” was correctly performed
Check the fuse F03 condition from the cockpit
fuse box.
Is the fuse good?
Is there the failure “DOORS BLOCKING
CONTACT”.
Check the continuity and the isolation related
to the mass, between the pin A 5 of the E.C.U.
decoder and the dashboard.(pin 6 from black
connector)
Is the wiring good?
Replace the fuse.
Analyse this failure and replace.
Fix the wiring.
Perform the following tests in order to find the
damaged element:
- if the anti starting indicator is permanently
lighted, disconnect the connector of the E.C.U.
decoder a nd check if t he indicator switches
off;
- if the anti starting system is turned off, connect
the pin A5 of t he wiring connector from the
E.C.U. decoder to an electric mass and check
if the indicator turns on.
Are the answers affirmatives?
Replace the instrument panel.
Replace the E .C.U. decoder.
Perform a conformity checking.
AFTER REPAIRING Check the operation of the anti starting system.
Remove by means of the CLIP tester the possible m emorised
failures.
No
No
No
Yes
Y e s
No
Yes
Yes
vnx.su