Downloaded from www.Manualslib.com manuals search engine 21MOTOR LOCK
DOOR
FRONT
LEFT RIGHT
FRONT
DOOR
LOCK
MOTOR12
P34
18
PK/BK
P33
18
OR/BK
1C3152
P33
18
OR/BK
5 P33
18
OR/BK
P34
18
PK/BK
6C231
P34
18
PK/BK
C23011
C23010
P34
16
PK/BK
P34
18
PK/BKP33
18
OR/BK
21C323
C20565
P33
18
OR/BKP34
18
PK/BK
P33
16
OR/BKP33
16
OR/BK
12
MOTOR LOCK
DOOR
REAR
LEFT RIGHT
REAR
DOOR
LOCK
MOTOR
21P34
18
PK/BK
1C324
2C301
P34
18
PK/BK
P34
16
PK/BK
P34
16
PK/BK
1C325
P34
18
PK/BK
2C303
P34
16
PK/BK
S303
2P33
18
OR/BK
1P33
16
OR/BK
P33
18
OR/BK
2P33
18
OR/BK
1P33
16
OR/BK
P33
16
OR/BK
S302 LEFT
DOOR
LOCK
SWITCH
FROMFROM
SWITCHLOCK DOORLEFT
P34
18
PK/BKP33
18
OR/BK
B (8W-61-2)A (8W-61-2)
PK/WT16 P34
MM
MM
PL-RHD8W-61 POWER DOOR LOCKS 8W - 61 - 3
PLR06102978W-1
Page 172 of 256

Downloaded from www.Manualslib.com manuals search engine 2
5
2 LOCK LEFT
DOOR
LOCK
SWITCH
1 UNLOCK
12
C2412
C2052
PK/VT18 P36 PK/VT16 P36 PK/VT16 P36
7C241
P36
16
PK/VT
2C231
P36
18
PK/VT
OR/VT18 P35
C2313
OR/VT16 P35
C2414
P35
16
OR/VT
P35
16
OR/VT
P35
18
OR/VT
3C205
9C241
1
4
24Z8
18
BK/VT
G203
Z8
14
BK/VT
Z8
14
BK/VT
4C205
2
2 LOCK RIGHT
DOOR
LOCK
SWITCH
1 UNLOCK
S310
BK/VT18Z8
1
(8W-15-6)(8W-15-6)
8W - 61 - 4 8W-61 POWER DOOR LOCKSPL-RHD
978W-1PLR06103
Page 173 of 256

Downloaded from www.Manualslib.com manuals search engine 8W-61 POWER DOOR LOCKS
INDEX
page page
DESCRIPTION AND OPERATION
HELPFUL INFORMATION.................. 5POWER DOOR LOCKS.................... 5
DESCRIPTION AND OPERATION
POWER DOOR LOCKS
The Power Distribution Center (PDC) supplies
voltage to the fuse block from the 40 amp HEAD-
LAMPS fuse on circuit A3. Fuse 3, a 20 amp located
in the fuse block, supplies battery voltage on the F35
circuit to both door lock switches.
The ground path for the system is through the left
door lock switch on the Z8 circuit. The grounding
point is located at the instrument panel left center
support brace.
LEFT DOOR SWITCH OPERATION (LOCK)
When the door lock switch is moved to the LOCK
position, voltage is supplied on the P35 circuit to the
bus bar located inside the right door switch, lock
side. Battery voltage is passed through the switch to
the P33 circuit to the door motors. Grounding is pro-
vided through the P34 circuit for all door motors
back to the right door switch. The ground is passed
through the bus bar internal to the switch, UNLOCK
side, to the P36 circuit. The P36 circuit connects to
the left front switch to a bus bar, internal to the
switch, and then to the Z8 circuit. The Z8 circuit con-
nects to its grounding point.
LEFT DOOR SWITCH OPERATION (UNLOCK)
When the switch is moved to the UNLOCK posi-
tion, voltage is supplied on the P36 circuit to the
right door switch, unlock side. The battery voltage is
passed through the switch internal bus bar to the
P34 circuit. The P34 circuit then connects to the door
motors on the unlock side. Grounding for the
UNLOCK function is provided by the P33 circuit.
The P33 circuit conects back to the right door
switch, LOCK side, and passes through the internal
bus bar to the P35 circuit. The P35 circuit conects
back to the left door switch, and passes through the
switch to the Z8 circuit. The Z8 circuit goes to it's
grounding point.
RIGHT DOOR SWITCH OPERATION (LOCK)
When the switch is moved to the LOCK position,
voltage is supplied to the P33 circuit, and then to the
door lock motors. The ground path is provided on theP34 circuit back to the right door switch. The ground
is passed through the switch internal bus bar to the
P36 circuit. The P36 circuit connects to the left door
switch and through to the Z8 circuit. The Z8 circuit
then connects to the grounding point at the left cen-
ter instrument panel support.
RIGHT DOOR SWITCH OPERATION (UNLOCK)
When the switch is moved to the UNLOCK posi-
tion voltage is supplied to the P34 circuit from the
switch to the door UNLOCK side of the motors. The
grounding path is through the LOCK side of the
motors, circuit P33, back to the switch. The ground
continues through the internal bus bar of the switch
on circuit P35 to the left door switch. At the left door
switch, the ground passes through that switches
internal bus bar to the Z8 grounding point.
HELPFUL INFORMATION
²Check the 40 amp fuse in the PDC.
²Check the 15 amp fuse in cavity 3 of the fuse
block.
²Check the grounding point on the instrument
panel left center support brace.
PL8W - 61 POWER DOOR LOCKS 8W - 61 - 5
Page 174 of 256

Downloaded from www.Manualslib.com manuals search engine
Page 175 of 256

Downloaded from www.Manualslib.com manuals search engine 8W-62 POWER MIRRORS
INDEX
page
SCHEMATICS AND DIAGRAMS........................................................... 1
DESCRIPTION AND OPERATION.......................................................... 5
Component Page
Circuit Breaker....................8W-62-2, 4
G203..............................8W-62-2
G203..............................8W-62-4
Left Power Mirror................8W-62-2, 3, 4
Power Folding Mirror Relay........8W-62-2, 3, 4Component Page
Power Mirror Fuse Holder...........8W-62-2, 4
Power Mirror Switch..............8W-62-2, 3, 4
Right Power Mirror...............8W-62-2, 3, 4
S310............................8W-62-2, 4
8W - 62 - 2 8W - 62 POWER MIRRORSPL
Page 176 of 256

Downloaded from www.Manualslib.com manuals search engine RUN F21
15A BREAKER CIRCUITHOLDER
FUSE
MIRROR
POWER
3 43 4
2 12
16534
2C1
C1
68C1 C141C1C217C1C135C15 UP 3 LEFT
4 RIGHT POWER
MIRROR
SWITCH
1 EXTEND
2 RETRACT
6 DOWN
G203
Z8
18
BK/VT
Z8
14
BK/VT
Z8
14
BK/VT
S310
4C205
5
4
43
6 34
LEFT
POWER
MIRROR RELAY MIRROR
FOLDING
POWER
RIGHT
POWER
MIRROR
P99
18
GY
P99
18
GY
P99
18
GY
4C231
8C205
P110
18
OR
P95
18
DB/WT
P95
18
DB/WT
P95
18
DB/WT
12 12C23111
C20511P93
18
YL/BK
P93
18
YL/BK
P93
18
YL/BK
P92
18
YLP94
18
WT/YLP91
18
WT/BK
P91
18
WT/BK
10C205
F121
18
TN/BK
(8W-62-4)
(8W-15-6) (8W-15-6)
(8W-62-3)(8W-62-3) (8W-62-4)(8W-11-10)
8W - 62 - 2 8W-62 POWER MIRRORSPL-RHD
978W-1PLR06201
Page 177 of 256

Downloaded from www.Manualslib.com manuals search engine 8
RELAY MIRROR
FOLDING
POWER
M
M
M
1
43
LEFT
MIRROR
34
15
M MM P90
18
LG/BK
P90
18
LG/BK
P90
18
LG/BK
9C231
9C205
P90
18
LG/BK
C21
POWER
MIRROR
SWITCH
6C1
P91
18
WT/BK
P91
18
WT/BK
P91
18
WT/BK
10C205
10C231
7C1 C18
5P95
18
DB/WT
P95
18
DB/WT
P95
18
DB/WT
P93
18
YL/BK
P93
18
YL/BK
P93
18
YL/BK
P99
18
GY
P99
18
GY
P99
18
GY
12 11 4
81112
P99
18
GY
P91
18
WT/BK
C143C1
P92
18
YLP94
18
WT/YL
66
6 RETRACT 4 LEFT
5 EXTEND 1 DOWN
2 UP
3 RIGHT
1
2
3
4 PTC
5
6PTC1
2
3
4 6 5
POWER POWER
3 RIGHT 2 UP
1 DOWN
5 EXTEND 4 LEFT
6 RETRACT MIRROR RIGHT
(8W-62-4)
(8W-62-2)
PL-RHD8W-62 POWER MIRRORS 8W - 62 - 3
PLR06202978W-1
Page 178 of 256

Downloaded from www.Manualslib.com manuals search engine 65 2
481
1
RIGHT
POWER
MIRROR LEFT
POWER
MIRROR
9C205
C2319
RUN F21
15A BREAKER CIRCUITHOLDER
FUSE
MIRROR
POWER
POWER
MIRROR
SWITCH
5 2
G203
P90
18
LG/BK
P90
18
LG/BK
P90
18
LG/BK
P90
18
LG/BK
F121
18
TN/BKF121
18
TN/BK
P110
18
OR
POWER
FOLDING
MIRROR
RELAY
Z8
18
BK/VT
Z8
14
BK/VT
Z8
18
BK/VT
S310
4C205
Z8 18BK/VT
(8W-62-3) (8W-62-3)
(8W-62-2)
(8W-15-6) (8W-11-10)
(8W-15-6)
8W - 62 - 4 8W-62 POWER MIRRORSPL-RHD
978W-1PLR06203
Page 179 of 256

Downloaded from www.Manualslib.com manuals search engine 8W-62 POWER MIRRORS
INDEX
page page
DESCRIPTION AND OPERATION
HELPFUL INFORMATION.................. 5POWER FOLDING MIRRORS............... 5
POWER MIRRORS....................... 5
DESCRIPTION AND OPERATION
POWER MIRRORS
Power for the power mirror switch is supplied on
circuit F121. This circuit is protected by a 15 amp
circuit breaker located in the right front door. Power
for the circuit breaker is supplied by circuit F21.
The F21 circuit is protected by a 30 amp circuit
breaker. This circuit breaker also supplies power to
the power windows.
The power mirror switch has a right and left posi-
tion. Moving the switch to either of these positions
changes the voltage path internal to the switch (ie.
changes polarity at the motors).
When the switch is moved to the RIGHT position
and mirror movement UP is selected, voltage is sup-
plied to the mirror on circuit P92 and the ground
path is supplied on circuit P90. The P90 circuit con-
nects from the mirror to the normally CLOSED con-
tacts in the mirror relay located in the right door.
When the right mirror DOWN movement is
selected voltage is supplied through the switch to cir-
cuit P110. The P110 circuit connects from the switch
to the power mirror relay located in the door, coil
side. Power on the coil side causes the contacts in the
relay to CLOSE connecting circuits F121 and P90.
The P90 circuit then supplies power to the DOWN
side of the motor. Ground for the motor is supplied
on circuit P92 back to the switch and then connects
to circuit Z8. The Z8 circuit connects from the switch
to its grounding point on the right instrument panel
center support.
If right door mirror movement LEFT is selected
voltage is supplied through the P94 circuit and the
ground is passed through circuit P91. When left mir-
ror RIGHT movement is selected the power and
ground are reversed.
When the switch is moved to the LEFT position
and mirror movement UP is selected, voltage is sup-
plied to the mirror on circuit P93 and the ground
path is supplied on circuit P90. The P90 circuit con-
nects from the mirror to the normally CLOSED con-
tacts in the mirror relay located in the right door.
When the left mirror DOWN movement is selected
voltage is supplied through the switch to circuit P110.
The P110 circuit connects from the switch to the powermirror relay located in the door, coil side. Power on the
coil side causes the contacts in the relay to CLOSE con-
necting circuits F121 and P90. The P90 circuit then
supplies power to the DOWN side of the motor. Ground
for the motor is supplied on circuit P93 back to the
switch and then connects to circuit Z8. The Z8 circuit
connects from the switch to its grounding point on the
right instrument panel center support.
If left door mirror movement LEFT is selected volt-
age is supplied through the P95 circuit and the
ground is passed through circuit P91. When left mir-
ror RIGHT movement is selected the power and
ground are reversed.
POWER FOLDING MIRRORS
Power for the power mirror switch is supplied on
circuit F121. This circuit is protected by a 15 amp
circuit breaker located in the right front door. Power
for the circuit breaker is supplied by circuit F21.
The F21 circuit is protected by a 30 amp circuit
breaker. This circuit breaker also supplies power to
the power windows.
When the operator selects mirrors RETRACT volt-
age is supplied on circuit F121 through the CLOSED
contacts in the switch to circuit P110. Circuit P110
connects to the power mirror relay coil side.
Voltage on the coil side of the relay causes the con-
tacts in the relay to CLOSE connecting circuits F121
and P90. The P90 circuit connects from the relay to
the power mirrors. Ground for the motors is supplied
on circuit P99 back to the power mirror switch. Inter-
nal to the switch the P99 circuit connects to the Z8
ground circuit.
When the operator selects the EXTEND function
power is supplied on circuit F121 through the
CLOSED contacts in the switch to circuit P99. The
P99 circuit connects to the power mirror motors.
Ground for the motors is supplied on circuit P90.
HELPFUL INFORMATION
²Check the 30 amp circuit breaker located behind
the fuse block
²Check the 15 amp circuit breaker located in the
right door
²Check the grounding point at the instrument
panel right center support
PL8W - 62 POWER MIRRORS 8W - 62 - 5
Page 180 of 256

Downloaded from www.Manualslib.com manuals search engine