charging DODGE RAM 2002 Service User Guide

DODGE RAM 2002 Service User Guide RAM 2002 DODGE DODGE https://www.carmanualsonline.info/img/12/56912/w960_56912-0.png DODGE RAM 2002 Service User Guide

Page 392 of 2255

DODGE RAM 2002  Service User Guide BATTERY SYSTEM DIAGNOSIS
CONDITION POSSIBLE CAUSES CORRECTION
THE BATTERY SEEMS
WEAK OR DEAD WHEN
ATTEMPTING TO START
THE ENGINE.1. The electrical system
ignition-off draw is excessive.1. Refer to the

Page 393 of 2255

DODGE RAM 2002  Service User Guide BATTERY SYSTEM DIAGNOSIS
CONDITION POSSIBLE CAUSES CORRECTION
THE BATTERY STATE OF
CHARGE CANNOT BE
MAINTAINED.1. The battery has an
incorrect size or rating for
this vehicle.1. Refer to Battery Syste

Page 394 of 2255

DODGE RAM 2002  Service User Guide ABNORMAL BATTERY DISCHARGING
Any of the following conditions can result in abnor-
mal battery discharging:
²A faulty or incorrect charging system compo-
nent. Refer to Charging System for the proper

Page 396 of 2255

DODGE RAM 2002  Service User Guide SPECIAL TOOLS
BATTERY
DESCRIPTION
A large capacity, low-maintenance storage battery
(Fig. 4) is standard factory-installed equipment on
this model. Refer to Battery System Specifications for
the prope

Page 397 of 2255

DODGE RAM 2002  Service User Guide the proper cleaning procedures, and Battery System
Inspection for the proper battery inspection proce-
dures. Refer to Standard Procedures for the proper
battery charging procedures.
WARNING: IF THE B

Page 398 of 2255

DODGE RAM 2002  Service User Guide CAUTION: Battery electrolyte will bubble inside the
battery case during normal battery charging. Elec-
trolyte boiling or being discharged from the battery
vents indicates a battery overcharging condi

Page 399 of 2255

DODGE RAM 2002  Service User Guide ²Temperature- A longer time will be needed to
charge a battery at -18É C (0É F) than at 27É C (80É
F). When a fast battery charger is connected to a cold
battery, the current accepted by the batt

Page 401 of 2255

DODGE RAM 2002  Service User Guide Test the specific gravity of the electrolyte in each
battery cell. If the specific gravity of all cells is above
1.235, but the variation between cells is more than
fifty points (0.050), the battery s

Page 402 of 2255

DODGE RAM 2002  Service User Guide (3) Rotate the load control knob (carbon pile rheo-
stat) to apply a 300 ampere load to the battery for
fifteen seconds, then return the control knob to the
Off position (Fig. 12). This will remove th

Page 403 of 2255

DODGE RAM 2002  Service User Guide Excessive IOD can be caused by:
²Electrical items left on.
²Faulty or improperly adjusted switches.
²Faulty or shorted electronic modules and compo-
nents.
²An internally shorted generator.
²Inte