ignition INFINITI QX56 2007 Factory Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2007, Model line: QX56, Model: INFINITI QX56 2007Pages: 3061, PDF Size: 64.56 MB
Page 2049 of 3061

GW-30
< SERVICE INFORMATION >
POWER WINDOW SYSTEM
Power Window and Door Lock/Unlock Switch RH Harness Connector Terminal Layout
INFOID:0000000003533031
Terminal and Reference Value for Power Window and Door Lock/Unlock Switch RH
INFOID:0000000003533032
15 BR Encoder power supplyWhen ignition switch ON or power
window timer operates10
17 B Ground — 0
19 W/R Battery power supply — Battery voltage Terminal Wire Color Item ConditionVoltage (V)
(Approx.)
LIIA2454E
Terminal Wire Color Item ConditionVoltage (V)
(Approx.)
3 W/B Limit switch and encoder ground — 0
4 G/R Encoder power supplyWhen ignition switch ON or power
window timer operates10
8LFront power window motor RH UP
signalWhen power window motor is op-
erated UP Battery voltage
9GFront power window motor RH
DOWN signalWhen power window motor is op-
erated DOWN Battery voltage
10 W/R Battery power supply — Battery voltage
11 B G r o u n d — 0
12 G/Y Encoder pulse signalWhen power window motor oper-
ates
OCC3383D
Page 2050 of 3061

POWER WINDOW SYSTEM
GW-31
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
GW
N
O
P
Terminal and Reference Value for BCMINFOID:0000000003533033
Refer to BCS-11, "Terminal and Reference Value for BCM".
Work FlowINFOID:0000000003533034
1. Check the symptom and customer's requests.
2. Understand the outline of system. Refer to GW-15, "
System Description".
3. According to the trouble diagnosis chart, repair or replace the cause of the malfunction.
Refer to GW-32, "
Trouble Diagnosis Symptom Chart".
4. Does power window system operate normally? Yes, GO TO 5, If No, GO TO 3.
5. Inspection End.
CONSULT-II Function (BCM)INFOID:0000000003533035
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT-II START PROCEDURE
Refer to GI-36, "CONSULT-II Start Procedure".
ACTIVE TEST
15 G/W Limit switch signalRear power window RH is be-
tween fully-open and just before
fully-closed position (ON)0
Rear power window RH is be-
tween just before fully-closed po-
sition and fully-closed position
(OFF)5
16 LG/W Power window serial linkWhen ignition switch is ON or
power window timer operating Terminal Wire Color Item ConditionVoltage (V)
(Approx.)
PIIA2344J
BCM diagnostic
test itemDiagnostic mode Content
Inspection by partWORK SUPPORTSupports inspections and adjustments. Commands are transmitted to the BCM for
setting the status suitable for required operation, input/output signals are received
from the BCM and received data is displayed.
DATA MONITOR Displays BCM input/output data in real time.
ACTIVE TEST Operation of electrical loads can be checked by sending drive signal to them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTR The results of transmit/receive diagnosis of CAN communication can be read.
ECU PART NUMBER BCM part number can be read.
CONFIGURATION Performs BCM configuration read/write functions.
Page 2051 of 3061

GW-32
< SERVICE INFORMATION >
POWER WINDOW SYSTEM
WORK SUPPORT
DATA MONITOR
Trouble Diagnosis Symptom ChartINFOID:0000000003533036
• Check that other systems using the signal of the following systems operate normally.
Te s t I t e m D e s c r i p t i o n
RETAINED PWRThis test is able to supply RAP signal (power) from BCM (body control module) to power window
system and power sunroof system (if equipped). Those systems can be operated when turning on
“RETAINED PWR” on CONSULT-II screen even if the ignition switch is turned OFF.
NOTE:
During this test, CONSULT-II can be operated with ignition switch in OFF position. “RETAINED
P W R ” s h o u l d b e t u r n e d “ O N ” o r “ O F F ” o n C O N S U LT- I I s c r e e n w h e n i g n i t i o n s w i t c h i s O N . T h e n t u r n
ignition switch OFF to check retained power operation. CONSULT-II might be stuck if “RETAINED
PWR” is turned “ON” or “OFF” on CONSULT-II screen when ignition switch is OFF.
Work item Description
RETAINED PWRRAP signal’s power supply period can be changed by mode setting. Selects RAP signal’s power
supply period between three steps
• MODE1 (45 sec.) / MODE2 (OFF) / MODE 3 (2 min.).
Work item Description
IGN ON SW Indicates (ON/OFF) condition of ignition switch
DOOR SW-DR Indicates (ON/OFF) condition of front door switch driver side
DOOR SW-AS Indicates (ON/OFF) condition of front door switch passenger side
Symptom Repair order Refer to page
None of the power windows can be operated using any switch1. BCM power supply and ground circuit checkBCS-15
2. Main power window and door lock/unlock
power supply and ground circuit checkGW-34
3. Power window serial link check front LH and
RHGW-46
Front power window LH alone does not operate1. Main power window and door lock/unlock
power supply and ground circuit checkGW-342. Front power window motor LH circuit checkGW-36
3. Replace main power window and door lock/
unlock switchEI-31
Front power window RH alone does not operate1. Power window and door lock/unlock switch
RH power supply and ground circuit checkGW-352. Power window serial link check front LH and
RHGW-46
3. Front power window motor RH circuit checkGW-37
4. Replace BCMBCS-24
Rear power window LH alone does not operate1. Rear power window control unit LH or RH
power supply and ground circuit checkGW-48
2. Rear power window switch LH or RH power
supply and ground circuit checkGW-49
3. Rear power window motor LH circuit checkGW-50
4. Power window serial link check rear LH and
RHGW-54
5. Replace BCMBCS-24
Page 2053 of 3061

GW-34
< SERVICE INFORMATION >
POWER WINDOW SYSTEM
BCM Power Supply and Ground Circuit Inspection
INFOID:0000000003533037
Refer to BCS-15, "BCM Power Supply and Ground Circuit Inspection".
Main Power Window and Door Lock/Unlock Switch Power Supply and Ground Circuit
Inspection
INFOID:0000000003533038
1.CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch ON.
2. Check voltage between main power window and door lock/
unlock switch connector D7 terminal 10, D8 terminal 19 and
ground.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2.CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch.
3. Check continuity between main power window and door lock/
unlock switch connector D8 terminal 17 and ground.
OK or NG
OK >> Power supply and ground circuit are OK.
NG >> Repair or replace harness.
3.CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM and main power window and door lock/unlock
switch.
3. Check continuity between BCM connector and main power win-
dow and door lock/unlock switch connectors.
4. Check continuity between BCM and ground.
Power windows do not operate by front door lock assembly LH (key
cylinder switch)1. Front door lock assembly LH (key cylinder
switch) checkGW-44
2. Replace main power window and door lock/
unlock switchEI-31
Power window lock switch does not function 1. Power window lock switch circuit checkGW-46
Symptom Repair order Refer to page
10 - Ground : Battery voltage
19 - Ground : Battery voltage
LIIA2297E
17 - Ground : Continuity should exist.
LIIA0392E
Connector
Te r m i n a lConnector
Terminal Continuity
AB
BCM: M2068Main power window and
door lock/unlock switch:
D710 Yes
69C
19 Yes Main power window and
door lock/unlock switch:
D8
LIIA2215E
Page 2054 of 3061

POWER WINDOW SYSTEM
GW-35
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
GW
N
O
P
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4.CHECK BCM OUTPUT SIGNAL
1. Connect BCM.
2. Turn ignition switch ON.
3. Check voltage between BCM connector M20 terminals 68, 69
and ground.
OK or NG
OK >> Check the condition of the harness and the connector.
NG >> Replace BCM. Refer to BCS-24, "
BCM".
Power Window and Door Lock/Unlock Switch RH Power Supply and Ground Circuit In-
spection
INFOID:0000000003533039
1.CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch ON.
2. Check voltage between power window and door lock/unlock
switch RH connector D105 terminal 10 and ground.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2.CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect power window and door lock/unlock switch RH.
3. Check continuity between power window and door lock/unlock
switch RH connector D105 terminal 11 and ground.
OK or NG
OK >> Power supply and ground circuit are OK.
NG >> Repair or replace harness.
3.CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH POWER SUPPLY CIRCUIT
Connector
Te r m i n a l
GroundContinuity
A
BCM: M2068 No
69 No
68 - Ground : Battery voltage
69 - Ground : Battery voltage
LIIA0917E
10 - Ground : Battery voltage
LIIA1257E
11 - Ground : Continuity should exist.
LIIA1258E
Page 2055 of 3061

GW-36
< SERVICE INFORMATION >
POWER WINDOW SYSTEM
1. Turn ignition switch OFF.
2. Disconnect BCM.
3. Check continuity between BCM connector M20 (A) terminal 69
and power window and door lock/unlock switch RH connector
D105 (B) terminal 10.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4.CHECK BCM OUTPUT SIGNAL
1. Connect BCM.
2. Turn ignition switch ON.
3. Check voltage between BCM connector M20 terminal 69 and
ground.
OK or NG
OK >> Check the condition of the harness and the connector.
NG >> Replace BCM. Refer to BCS-24, "
BCM" .
Front Power Window Motor LH Circuit InspectionINFOID:0000000003533040
1.CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL
1. Turn ignition switch ON.
2. Check voltage between main power window and door lock/
unlock switch connector D7 terminals 8, 11 and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace main power window and door lock/unlock switch. Refer to EI-31, "
Removal and Installa-
tion".
2.CHECK POWER WINDOW MOTOR CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch and
front power window motor LH.
3. Check continuity between main power window and door lock/
unlock switch connector D7 terminals 8, 11 and front power win-
dow motor LH connector D9 terminals 1, 2.
OK or NG
OK >> Replace front power window motor LH. Refer to GW-59.
NG >> Repair or replace harness.69 - 10 : Continuity should exist.
LIIA2298E
69 - Ground : Battery voltage
WIIA0508E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
D78
GroundUP Battery voltage
DOWN 0
11UP 0
DOWN Battery voltage
LIIA0317E
8 - 2 : Continuity should exist.
11 - 1 : Continuity should exist.
LIIA1260E
Page 2056 of 3061

POWER WINDOW SYSTEM
GW-37
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
GW
N
O
P
Front Power Window Motor RH Circuit InspectionINFOID:0000000003533041
1.CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH OUTPUT SIGNAL
1. Connect power window and door lock/unlock switch RH.
2. Turn ignition switch ON.
3. Check voltage between power window and door lock/unlock
switch RH connector D105 terminals 8, 9 and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace power window and door lock/unlock switch RH. Refer to EI-31, "
Removal and Installa-
tion".
2.CHECK FRONT POWER WINDOW MOTOR RH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front power window motor RH and power window
and door lock/unlock switch RH.
3. Check continuity between power window and door lock/unlock
switch RH connector D105 terminals 8, 9 and front power win-
dow motor RH connector D104 terminals 1, 2.
OK or NG
OK >> Replace front power window motor RH. Refer to GW-59
.
NG >> Repair or replace harness.
Limit Switch Circuit Inspection Front LHINFOID:0000000003533042
1.CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH LIMIT SIGNAL
1. Turn ignition switch ON.
2. Check voltage between main power window and door lock/
unlock switch connector D7 termimal 9 and ground.
OK or NG
OK >> Limit switch circuit is OK.
NG >> GO TO 2.
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
D1059
GroundUP 0
DOWN Battery voltage
8UP Battery voltage
DOWN 0
LIIA1261E
8 - 2 : Continuity should exist.
9 - 1 : Continuity should exist.
LIIA1262E
ConnectorTe r m i n a l
Condition Voltage (V)
(Approx.)
(+) (-)
D7 9 GroundFront power window LH is
between fully-open and just
before fully-closed position
(ON)0
Front power window LH is
between just before fully-
closed position and fully-
closed position (OFF)5
LIIA0339E
Page 2057 of 3061

GW-38
< SERVICE INFORMATION >
POWER WINDOW SYSTEM
2.CHECK FRONT POWER WINDOW MOTOR LH LIMIT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect front power window motor LH.
3. Turn ignition switch ON.
4. Check voltage between front power window motor LH connector
D9 terminal 5 and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 5.
3.CHECK LIMIT SWITCH GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between front power window motor LH connec-
tor D9 terminal 6 and ground.
OK or NG
OK >> Replace front power window motor LH. Refer to GW-59.
NG >> GO TO 4.
4.CHECK HARNESS CONTINUITY
1. Disconnect main power window and door lock/unlock switch.
2. Check continuity between front power window motor LH connec-
tor D9 terminal 6 and main power window and door lock/unlock
switch connector D7 terminal 2.
OK or NG
OK >> Replace main power window and door lock/unlock
switch. Refer to EI-31, "
Removal and Installation".
NG >> Repair or replace harness.
5.CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch.
3. Check continuity between front power window motor LH connec-
tor D9 terminal 5 and main power window and door lock/unlock
switch connector D7 terminal 9.
OK or NG
OK >> Replace main power window and door lock/unlock
switch. Refer to EI-31, "
Removal and Installation".
NG >> Repair or replace harness.
Limit Switch Circuit Inspection Front RHINFOID:0000000003533043
1.CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH LIMIT SIGNAL 5 - Ground : Approx. 5V
LIIA0922E
6 - Ground : Continuity should exist.
LIIA0923E
6 - 2 : Continuity should exist.
LIIA0924E
5 - 9 : Continuity should exist.
LIIA0925E
Page 2058 of 3061

POWER WINDOW SYSTEM
GW-39
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
GW
N
O
P
1. Turn ignition switch ON.
2. Check voltage between power window motor RH connector
D105 terminal 15 and ground.
OK or NG
OK >> Limit switch circuit is OK.
NG >> GO TO 2.
2.CHECK FRONT POWER WINDOW MOTOR RH LIMIT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect front power window motor RH.
3. Turn ignition switch ON.
4. Check voltage between front power window motor RH connector
D104 terminal 5 and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 5.
3.CHECK LIMIT SWITCH GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between front power window motor RH con-
nector D104 terminal 6 and ground.
OK or NG
OK >> Replace front power window motor RH. Refer to GW-59.
NG >> GO TO 4.
4.CHECK HARNESS CONTINUITY
1. Disconnect power window and door lock/unlock switch RH.
2. Check continuity between front power window motor RH con-
nector D104 terminal 6 and power window and door lock/unlock
switch RH connector D105 terminal 3.
OK or NG
OK >> Replace power window and door lock/unlock switch RH.
Refer to EI-31, "
Removal and Installation".
NG >> Repair or replace harness.
5.CHECK HARNESS CONTINUITY
ConnectorTe r m i n a l s
Condition Voltage (V)
(Approx.)
(+) (-)
D105 15 GroundFront power window RH is
between fully-open and just
before fully-closed position
(ON)0
Front power window RH is
between just before fully-
closed position and fully-
closed position (OFF)5
LIIA1263E
5 - Ground : Approx. 5V
LIIA0922E
6 - Ground : Continuity should exist.
LIIA0923E
6 - 3 : Continuity should exist.
LIIA1264E
Page 2059 of 3061

GW-40
< SERVICE INFORMATION >
POWER WINDOW SYSTEM
1. Turn ignition switch OFF.
2. Disconnect power window and door lock/unlock switch RH.
3. Check continuity between power window and door lock/unlock
switch RH connector D105 terminal 15 and front power window
motor RH connector D104 terminal 5.
OK or NG
OK >> Replace power window and door lock/unlock switch RH.
Refer to EI-31, "
Removal and Installation".
NG >> Repair or replace harness.
Encoder Circuit Inspection Front LHINFOID:0000000003533044
1.CHECK FRONT POWER WINDOW MOTOR LH POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect front power window motor LH.
3. Turn ignition switch ON.
4. Check voltage between front power window motor LH connector
D9 terminal 4 and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2.CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch.
3. Check continuity between front power window motor LH connec-
tor D9 terminal 4 and main power window and door lock/unlock
switch connector D7 terminal 15.
OK or NG
OK >> Replace main power window and door lock/unlock
switch. Refer to EI-31, "
Removal and Installation".
NG >> Repair or replace harness.
3.CHECK ENCODER GROUND
1. Turn ignition switch OFF.
2. Check continuity between front power window motor LH connec-
tor D9 terminal 6 and ground.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4.CHECK ENCODER GROUND CIRCUIT15 - 5 : Continuity should exist.
LIIA1265E
4 - Ground : Approx. 10V
WIIA0513E
4 - 15 : Continuity should exist.
LIIA0936E
6 - Ground : Continuity should exist.
LIIA0923E