Page 71 of 2100

ISUZU AXIOM 2002  Service Manual PDF HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±45
Evaporator Assembly
Evaporator Assembly and Associated Parts
874R200015
Legend
(1) Refrigerant Line
(2) Drain Hose
(3) Dash Side Trim Panel
(4)

Page 72 of 2100

ISUZU AXIOM 2002  Service Manual PDF 1A±46
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
9. Disconnect drain hose.
10. Disconnect refrigerant line.
Use a back-up wrench when disconnecting and
reconnecting the refrigerant lines.
Whe

Page 73 of 2100

ISUZU AXIOM 2002  Service Manual PDF HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±47
Duct Sensor, Evaporator Core and/or Expansion Valve
Disassembled View
874R200012
Legend
(1) Lining
(2) Expansion Valve
(3) O-ring
(4) Evaporator

Page 74 of 2100

ISUZU AXIOM 2002  Service Manual PDF 1A±48
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Lift to remove the upper case.
874R200007
9. Remove evaporator core.
874R200008
10. Remove expansion valve.
Tear off the insulator carefully.

Page 75 of 2100

ISUZU AXIOM 2002  Service Manual PDF HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±49
Refrigerant Line
Refrigerant Line and Associated Parts
852R200007
Legend
(1) Clip and Clamp
(2) Liquid Line (High-Pressure Pipe)
(3) Discharge L

Page 76 of 2100

ISUZU AXIOM 2002  Service Manual PDF 1A±50
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
11. Disconnect discharge line (High-pressure hose)
using a back-up wrench.
Use a backup wrench when disconnecting and
reconnecting the refriger

Page 77 of 2100

ISUZU AXIOM 2002  Service Manual PDF HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±51
Main Data And Specifications
General Specifications
Heater Unit
Temperature controlReheat air mix system
Capacity4.3 kw (3700 Kcal./hr.)
Air flo

Page 78 of 2100

ISUZU AXIOM 2002  Service Manual PDF 1A±52
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Torque Specifications
852R200009
874R200013

Page 79 of 2100

ISUZU AXIOM 2002  Service Manual PDF HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±53
Compressor
Service Precaution
WARNING: THIS VEHICLE HAS A SUPPLEMENTAL
RESTRAINT SYSTEM (SRS). REFER TO THE SRS
COMPONENT LOCATION VIEW IN ORDER

Page 80 of 2100

ISUZU AXIOM 2002  Service Manual PDF 1A±54
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Diagnosis
ConditionPossible causeCorrection
Noise from compressionDefective rotor/pistonReplace compressor/cylinder and
shaft assembly
Defective