1B Ð 56 AIR CONDITIONING
DIAGNOSIS
Rear Air Conditioning Cycle Diagnosis
Condition Possible Cause Correction
No cooling or insufficient cooling
Insufficient velocity of cooling airFront air conditioner not switched
on.
Other
Clogged filter
OtherSwitch front A/C switch ON.
See front air conditioner
workshop manual.
Clean or replace cooling unit filter.
See front air conditioner
workshop manual.
AIR CONDITIONING 1B Ð 57
FAN CONTROL SWITCH
Inspection
Using an electric circuit tester, check continuity between
terminals.
If not as specified, replace the switch.
1234
OFF
LOW
MEDIUM
HIGH
Fan control switch
OFF
L 0.5 LG
0.85 Y
0.85 RG 0.85 B
M
H1
2
3
4
Resistor
0.5½1.1½
Mo MH ML
0.5 LG(ML)
0.85 WR(Mo)0.85 RG(MH)
RESISTOR
Inspection
Using an electric circuit tester, check the resistance
between the terminals specified below.
If the resistances are not as specified, replace the resistor.
Terminal Resistance (½)
Mo ~ MH 0.5
Mo ~ ML 1.6
825RY00058
826RY00016
AIR CONDITIONING 1B Ð 59
FAN MOTOR
Inspection
1. Disconnect the fan motor connector from the A/C
harness.
2. Connect the batteryÕs positive terminal to the No.5
terminal of the fan motor and the negative terminal to
the No.4 terminal.
3. Check that the fan motor operates correctly.
Fan motor connector
0.85 B (-) 4
0.85 R (+) 5
872RY00002