MITSUBISHI 380 2005 Workshop Manual

MITSUBISHI 380 2005 Workshop Manual 380 2005 MITSUBISHI MITSUBISHI https://www.carmanualsonline.info/img/19/57086/w960_57086-0.png MITSUBISHI 380 2005 Workshop Manual
Trending: coolant capacity, high beam, recommended oil, battery capacity, check transmission fluid, service indicator, Ignition

Page 341 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-341
STEP 2. Check the input signal by using "FUNCTION 
DIAG." menu of the SWS monitor.
Set each switch to the following condition before ch

Page 342 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-342
STEP 3. Check fog lamp relay connector A-05X for loose, 
corroded or damaged terminals, or terminals pushed back 
in the connector.
Q: Is fog l

Page 343 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-343
STEP 5. Check the battery power supply circuit to the fog 
lamp relay. Measure the voltage at fog lamp relay 
connector A-05X.
The top and bott

Page 344 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-344
STEP 7. Check front-ECU connector A-11X for loose, 
corroded or damaged terminals, or terminals pushed back 
in the connector.
Q: Is front-ECU

Page 345 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-345
INSPECTION PROCEDURE J-2: Fog Light: Fog lamps do not go out when the headlamps (low-beam) 
are turned off while the fog lamps are on.
.
TECHNI

Page 346 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-346
STEP 1. Verify that the fog lamps and the fog lamp 
indicator lamp illuminate.
Q: Do the fog lamps and the fog lamp indicator lamp 
illuminate

Page 347 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-347
STEP 4. Check the ground circuit to the fog lamp (LH). 
Measure the resistance at fog lamp (LH) connector A-22.
(1) Disconnect fog lamp (LH) co

Page 348 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-348
STEP 7. Check the wiring harness between fog lamp relay 
connector A-05X (terminal 4) and fog lamp (LH) connector 
A-22 (terminal 1).
Q: Is the

Page 349 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-349
STEP 10. Check the ground circuit to the fog lamp (RH). 
Measure the resistance at fog lamp (RH) connector A-28.
(1) Disconnect fog lamp (RH) c

Page 350 of 1500

MITSUBISHI 380 2005  Workshop Manual SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-350
STEP 13. Check the wiring harness between fog lamp relay 
connector A-05X (terminal 4) and fog lamp (RH) connector 
A-28 (terminal 1).
Q: Is th
Trending: radiator cap, keyless entry, set clock, door lock, water pump, Start system, brake light