SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-274
Use Diagnostic Tool MB991958 to select "ECU COMM
Check" on the SWS monitor display.
Check the following ECUs:
ETACS-ECU
Column-ECU
Front-ECU
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "LOCK" (OFF) position.
(3) Operate Diagnostic Tool MB991958 according to the
procedure below to display "ECU COMM Check."
a. Select "System select."
b. Select "SWS."
c. Select "SWS MONITOR."
d. Select "ECU COMM Check."
(4) Diagnostic Tool MB991958 should show "OK" on the "ECU
COMM Check" menus for the "ETACS ECU", "COLUMN
ECU" and "FRONT ECU" menus.
Q: Is "OK" displayed for both the "ETACS ECU", "COLUMN
ECU" and "FRONT ECU" menus?
"OK" is displayed for all the items : Replace the
front-ECU. Verify that the headlamps and the
taillamps illuminate normally.
"NG" is displayed for the "ETACS ECU" menu : Refer to
Inspection Procedure A-3 "Communication with the
ETACS-ECU is not possible P.54B-74."
"NG" is displayed for the "COLUMN ECU" menu : Refer
to Inspection Procedure A-2 "Communication with the
column switch (column-ECU) is not possible
P.54B-68."
"NG" is displayed for the "FRONT ECU" menu : Refer to
Inspection Procedure A-4 "Communication with the
front-ECU is not possible P.54B-80."
Page 304 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-304
STEP 4. Use Diagnostic Tool MB991958 to select "ECU
COMM Check" on the SWS monitor display.
Check the ETACS-ECU.
Connect special tool MB991910 before connecting special
tool MB991812. Be sure to connect special tool MB991806
after turning on special tool MB991824.
(1) Connect the SWS monitor. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "LOCK" (OFF) position.
(3) Operate Diagnostic Tool MB991958 according to the
procedure below to display "ECU COMM Check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."
(4) Diagnostic Tool MB991958 should show "OK" on the "ECU
COMM Check" menu for the "ETACS ECU" menu.
Q: Is "OK" displayed for the "ETACS ECU" menu?
YES : Go to Step 5.
NO : Refer to Inspection Procedure A-3 "Communication
with the ETACS-ECU is not possible P.54B-74."
STEP 5. Replace the combination meter.
(1) Replace the combination meter.
(2) Check that the high beam indicator lamp illuminates
normally.
Q: Does the high beam indicator lamp illuminate normally?
YES : No action is necessary and testing is complete.
NO : Replace the ETACS-ECU. Check that the high beam
indicator lamp illuminates normally.
Page 307 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-307
STEP 2. Check the input signal by using "DATA LIST"
menu of the SWS monitor.
Check the input signals from the following switches:
Ignition switch: "ON" to "OFF"
Lighting switch: "TAIL" or "HEAD"
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "LOCK" (OFF) position.
(3) Operate Diagnostic Tool MB991958 according to the
procedure below to display "H/L AUTO-CUT."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f. Select "LIGHTING."
g. Select "H/L AUTO-CUT."
(4) Check that normal conditions are displayed for the items
described in the table below.
(5) When the driver's door is opened, check that normal
conditions are displayed for the items described in the table
below.
Q: Does the Diagnostic Tool MB991958 display the items
"TAILLAMP SW", "IG SW IG1", "FRONT DOOR SW" and
"H/L AUTO-CUT" as normal condition?
Normal conditions are displayed for all the items :
Replace the front-ECU. Verify that the headlamp
automatic shutdown function works normally.
Normal condition is not displayed for "TAILLAMP SW" :
Refer to Inspection Procedure M-5 "ETACS-ECU
does not receive any signal from the taillamp switch
P.54B-420."
Normal condition is not displayed for "IG SW (IG1)" :
Refer to Inspection Procedure M-2 "ETACS-ECU
does not receive any signal from the ignition switch ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 01 TAILLAMP SW ON
ITEM 30 IG SW (IG1) OFF
ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 32 FRONT DOOR SW ON
ITEM 35 H/L AUTO-CUT ON
Page 313 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-313
STEP 7. Check the input signal by using "FUNCTION
DIAG." menu of the SWS monitor.
Check the input signals from the following switches:
Ignition switch: ON
Turn-signal lamp switch: RH
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "LOCK" (OFF) position.
(3) Operate Diagnostic Tool MB991958 according to the
procedure below to display "TURN SIG.RH."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f. Select "TURN SIGNAL."
g. Select "TURN SIG.RH."
(4) Check that normal conditions are displayed for the items
described in the table below.
Q: Does the Diagnostic Tool MB991958 display the items
"T/S RH SW" and "IG SW (IG1)" as normal condition?
Normal conditions are displayed for all the items : Go to
St e p 8 .
Normal condition is not displayed for "T/S RH SW" :
Refer to Inspection Procedure M-5 "ETACS-ECU
does not receive any signal from the turn-signal lamp
switch P.54B-420."
Normal condition is not displayed for "IG SW (IG1)" :
Refer to Inspection Procedure M-2 "ETACS-ECU
does not receive any signal from the ignition switch
(IG1) P.54B-408." ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 10 T/S RH SW ON
ITEM 30 IG SW (IG1) ON
Page 314 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-314
STEP 8. Check the input signal by using "FUNCTION
DIAG." menu of the SWS monitor.
If the Ignition switch is turned to the "ON" position and the
turn-signal lamp switch (LH) is turned on, normal conditions
should be displayed for the items described in the table below.
(1) Operate Diagnostic Tool MB991958 according to the
procedure below to display "TURN SIG.LH."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f. Select "TURN SIGNAL."
g. Select "TURN SIG.LH."
(2) Check that normal conditions are displayed for the item
described in the table below.
Q: Do the Diagnostic Tool display the item "T/S LH SW" as
normal condition?
YES : Replace the ETACS-ECU. Verify that the turn-signal
lamps illuminate normally.
NO : Refer to Inspection Procedure M-5 "ETACS-ECU
does not receive any signal from the turn-signal lamp
switch P.54B-420."
INSPECTION PROCEDURE I-2: Flasher Timer: Hazard warning lamps do not flash when the hazard
warning lamp switch is turned on.
.
CIRCUIT OPERATION
If the ETACS-ECU receives "ON" signal from the
hazard warning lamp switch, the ETACS-ECU turns
on the flasher timer (incorporated in the
ETACS-ECU), thus causing the turn-signal lamps to
flash.
.
TECHNICAL DESCRIPTION (COMMENT)
If the hazard warning lamps do not flash, the power
supply line to the ETACS-ECU (dedicated to the
turn-signal lamps) or the ETACS-ECU may be defec-
tive.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective ITEM No. ITEM NAME NORMAL CONDITION
ITEM 11 T/S LH SW ON
Page 338 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-338
STEP 4. Use Diagnostic Tool MB991958 to select "ECU
COMM Check" on the SWS monitor display.
Check the ETACS-ECU.
Connect special tool MB991910 before connecting special
tool MB991812. Be sure to connect special tool MB991806
after turning on special tool MB991824.
(1) Connect the SWS monitor. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "ON" position.
(3) Operate Diagnostic Tool MB991958 according to the
procedure below to display "ECU COMM Check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."
(4) Diagnostic Tool MB991958 should show "OK" on the "ECU
COMM Check" menu for the "ETACS ECU" menu.
Q: Is "OK" displayed for the "ETACS ECU" menu?
YES : Go to Step 5.
NO : Refer to Inspection Procedure A-3 "Communication
with the ETACS-ECU is not possible P.54B-74."
STEP 5. Replace the combination meter.
(1) Replace the combination meter.
(2) Check that the turn-signal lamp indicator lamps illuminate
normally.
Q: Are the turn-signal indicator lamps in good condition?
YES : No action is necessary and testing is complete.
NO : Replace the ETACS-ECU. Check that the turn-signal
lamp indicator lamps illuminate normally.
Page 341 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-341
STEP 2. Check the input signal by using "FUNCTION
DIAG." menu of the SWS monitor.
Set each switch to the following condition before checking input
signal from the fog lamp switch:
Ignition switch: ON
Fog lamp switch: ON
NOTE: Turn the ignition switch to the "ON" position in order to
disable the headlamp automatic shutdown function.
To prevent damage to Diagnostic Tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting Diagnostic Tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Operate Diagnostic Tool MB991958 according to the
procedure below to display "F.FOG."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Function Diag."
f. Select "LIGHTING."
g. Select "F.FOG."
(3) Check that normal conditions are displayed for the items
described in the table below.
Q: Does the Diagnostic Tool MB991958 display the items
"IG SW (IG1)" and "F.FOG LAMP" as normal condition?
Normal conditions are displayed for all the items : Go to
St e p 3 .
Normal condition is not displayed for "IG SW (IG1)" :
Refer to Inspection Procedure M-2 "ETACS-ECU
does not receive any signal from the ignition switch
(IG1) P.54B-408."
Normal condition is not displayed for "F.FOG LAMP" :
Refer to Inspection Procedure M-3 "ETACS-ECU
does not receive any signal from the fog lamp switch
P.54B-410." ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 30 IG SW (IG1) ON
ITEM 36 F.FOG LAMP ON
Page 354 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-354
STEP 4. Use Diagnostic Tool MB991958 to select "ECU
COMM Check" on the SWS monitor display.
Check the ETACS-ECU.
Connect special tool MB991910 before connecting special
tool MB991812. Be sure to connect special tool MB991806
after turning on special tool MB991824.
(1) Connect the SWS monitor. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "ON" position.
(3) Operate Diagnostic Tool MB991958 according to the
procedure below to display "ECU COMM Check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."
(4) Diagnostic Tool MB991958 should show "OK" on the "ECU
COMM Check" menu for the "ETACS ECU" menu.
Q: Is "OK" displayed for the "ETACS ECU" menu?
YES : Go to Step 5.
NO : Refer to Inspection Procedure A-3 "Communication
with the ETACS-ECU is not possible P.54B-74."
STEP 5. Replace the combination meter.
(1) Replace the combination meter.
(2) Check that the fog lamp indicator lamp illuminates normally.
Q: Is the fog lamp indicator lamp operating properly?
YES : No action is necessary and testing is complete.
NO : Replace the ETACS-ECU. Check that the fog lamp
indicator lamp illuminates normally.
Page 361 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-361
STEP 1. Use diagnostic tool MB991958 to select "ECU
COMM Check" on the SWS monitor display.
Check the ETACS-ECU.
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "LOCK" (OFF) position.
(3) Operate diagnostic tool MB991958 according to the
procedure below to display "ECU COMM Check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."
(4) Diagnostic tool MB991958 should show "OK" on the "ECU
COMM Check" menu for the "ETACS ECU" menu.
Q: Is "OK" displayed for the "ETACS ECU" menu?
YES : Go to Step 2.
NO : Refer to Inspection Procedure A-3 "Communication
with the ETACS-ECU is not possible P.54B-74."
Page 362 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-362
STEP 2. Check the input signal by using "DATA LIST"
menu of the SWS monitor.
Check the input signals from the following switches:
Ignition switch: ON or START
Driver’s or front passenger’s door: open
(1) Operate diagnostic tool MB991958 according to the
procedure below to display "ETACS ECU."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Data List."
f. Select "ETACS ECU."
(2) Check that normal conditions are displayed for the items
described in the table below.
Q: Does the diagnostic tool MB991958 display the items
"IG SW (IG1)" and "FRONT DOOR SW" as normal
condition?
Normal conditions are displayed for all the items : Go to
St e p 3 .
Normal condition is not displayed for "IG SW (IG1)" :
Refer to Inspection Procedure M-2 "ETACS-ECU
does not receive any signal from the ignition switch
(IG1) P.54B-408."
Normal condition is not displayed for "FRONT DOOR
SW" : Refer to Inspection Procedure M-4 "ETACS-ECU
does not receive any signal from the front door
switches P.54B-413." ITEM NO. ITEM NAME NORMAL CONDITION
ITEM 30 IG SW (IG1) ON
ITEM 32 FRONT DOOR SW ON