check engine MITSUBISHI MONTERO 2000 Service Manual PDF

MITSUBISHI MONTERO 2000 Service Manual PDF MONTERO 2000 MITSUBISHI MITSUBISHI https://www.carmanualsonline.info/img/19/57331/w960_57331-0.png MITSUBISHI MONTERO 2000 Service Manual PDF

Page 299 of 1839

MITSUBISHI MONTERO 2000  Service Manual PDF GDI -Troubleshooting <M/T>13A-85
Inspection procedure 10
When the engine is hot, it stalls at idling. (Die out)
Probable cause
The cause is probably an improper air/fuel ratio, faulty electronic-contr

Page 300 of 1839

MITSUBISHI MONTERO 2000  Service Manual PDF GDI -Troubleshooting <M/T>13A-86
From the previouspage
OK
MUT-
IIData list
27 Power steering fluid pressure switch (Refer to P.13A-105.)NGCheck the power steering fluid pressure switch system. (Refer

Page 301 of 1839

MITSUBISHI MONTERO 2000  Service Manual PDF GDI -Troubleshooting <M/T>13A-87
Inspection procedure 11
The engine stalls when starting the car. (Pass out)
Probable cause
The cause is probably poor ignition due to a malfunctioning sparkplug(weak s

Page 302 of 1839

MITSUBISHI MONTERO 2000  Service Manual PDF GDI -Troubleshooting <M/T>13A-88
Inspection procedure 12
The engine stalls when decelerating.
Probable cause
The cause is probably an improper air/fuel ratio due to a faulty EGR system, or poor
intake

Page 303 of 1839

MITSUBISHI MONTERO 2000  Service Manual PDF GDI -Troubleshooting <M/T>13A-89
Inspection procedure 13
Hesitation, sag, stumble, poor acceleration or surge
Probable cause
The cause is probably a malfunction of the ignition system, electronic-cont

Page 304 of 1839

MITSUBISHI MONTERO 2000  Service Manual PDF GDI -Troubleshooting <M/T>13A-90
From the previouspage
OK
Measure high fuelpressure between the fuelpump (highpressure)
and injector. (Refer to P.13A-224.)NG
Repair
OK
Check ignition coil spark for ea

Page 306 of 1839

MITSUBISHI MONTERO 2000  Service Manual PDF GDI -Troubleshooting <M/T>13A-92
Inspection procedure 18
Too high CO and HC concentration when idling
Probable cause
The cause is probably an incorrect air/fuel ratioDMalfunction of air/fuel ratio con

Page 308 of 1839

MITSUBISHI MONTERO 2000  Service Manual PDF GDI -Troubleshooting <M/T>13A-94
Inspection procedure 19
Low alternator output voltage (approx.12.3 V)
Probable cause
The cause is probably a malfunction of the alternator or one of the problems
liste

Page 309 of 1839

MITSUBISHI MONTERO 2000  Service Manual PDF GDI -Troubleshooting <M/T>13A-95
Inspection procedure 21
A/C condenser fan is inoperative
Probable cause
The fan motor relay is controlled by turning on and off the power transistor in
the engine-ECU.

Page 310 of 1839

MITSUBISHI MONTERO 2000  Service Manual PDF GDI -Troubleshooting <M/T>13A-96
Inspection procedure 22
Clutch switch system malfunction
Probable cause
The clutchpedalswitch sends a signal indicating clutchpedal depression to the
engine-ECU. The e