NISSAN LATIO 2011 Service Repair Manual
LATIO 2011
NISSAN
NISSAN
https://www.carmanualsonline.info/img/5/57357/w960_57357-0.png
NISSAN LATIO 2011 Service Repair Manual
Trending: fuel tank removal, start stop button, CD player, spark plugs replace, brakes, wiring diagram, parking sensors
Page 3481 of 3787
ELECTRICAL UNITS LOCATIONPG-61
< SERVICE INFORMATION >
C
DE
F
G H
I
J
L
M A
B
PG
N
O P
ELECTRICAL UNITS LOCATION
Electrical Units LocationINFOID:0000000005928357
ENGINE COMPARTMENT
ABMIA2326GB
Revision: May 2010 2011 Versa
Page 3482 of 3787
PG-62
< SERVICE INFORMATION >
ELECTRICAL UNITS LOCATION
PASSENGER COMPARTMENT
AAMIA0145GB
Revision: May 20102011 Versa
Page 3483 of 3787
ELECTRICAL UNITS LOCATIONPG-63
< SERVICE INFORMATION >
C
DE
F
G H
I
J
L
M A
B
PG
N
O P
AAMIA0146GB
Revision: May 2010 2011 Versa
Page 3484 of 3787
PG-64
< SERVICE INFORMATION >
ELECTRICAL UNITS LOCATION
LUGGAGE COMPARTMENT
ABMIA1598GB
Revision: May 20102011 Versa
Page 3485 of 3787
HARNESS CONNECTORPG-65
< SERVICE INFORMATION >
C
DE
F
G H
I
J
L
M A
B
PG
N
O P
HARNESS CONNECTOR
DescriptionINFOID:0000000005928358
HARNESS CONNECTOR (TAB-LOCKING TYPE)
• The tab-locking type connectors help prevent accidental looseness or disconnection.
• The tab-locking type connectors are disconnected by pushi ng or lifting the locking tab(s). Refer to the illus-
tration below.
Refer to the next page for description of the slide-locking type connector.
CAUTION:
Do not pull the harness or wires when disconnecting the connector.
[Example]
HARNESS CONNECTOR (SLIDE-LOCKING TYPE)
• A new style slide-locking type connector is used on certain systems and components, especially those related to OBD.
• The slide-locking type connectors help prevent incomplete locking and accidental looseness or disconnec- tion.
• The slide-locking type connectors are disconnected by pushing or pulling the slider. Refer to the figure
below.
SEL769DA
Revision: May 2010 2011 Versa
Page 3486 of 3787
PG-66
< SERVICE INFORMATION >
HARNESS CONNECTOR
CAUTION:
• Do not pull the harness or wires when disconnecting the connector.
• Be careful not to damage the connector su pport bracket when disconnecting the connector.
[Example]
HARNESS CONNECTOR (LEVER LOCKING TYPE)
• Lever locking type harness connectors are used on certain control units and control modules such as ECM, ABS actuator and electric unit (control unit), etc.
• Lever locking type harness connectors are also used on super multiple junction (SMJ) connectors.
• Always confirm the lever is fully locked in place by moving the lever as far as it will go to ensure full connec- tion.
CAUTION:
SEL769V
Revision: May 2010 2011 Versa
Page 3487 of 3787

HARNESS CONNECTORPG-67
< SERVICE INFORMATION >
C
DE
F
G H
I
J
L
M A
B
PG
N
O P
Always confirm the lever is fully released (loosened) before attempting to disconnect or connect these
connectors to avoid damage to th e connector housing or terminals.
HARNESS CONNECTOR (DIRECT-CONNECT SRS COMPONENT TYPE)
• SRS direct-connect type harness connectors are used on certain SRS components such as air bag modules
and seat belt pre-tensioners.
• Always pull up to release black locking tab prior to removing connector from SRS component.
• Always push down to lock black locking tab after installing connector to SRS component. When locked, the
black locking tab is level with the connector housing.
CAUTION:
• Do not pull the harness or wir es when removing connectors
from SRS components.
LKIA0670E
1. Control unit with single lever
A. Fasten
B. Loosen
C. Lever 2. Control unit with dual levers
A. Levers
B. Fasten
C. Loosen 3. SMJ connector
A. Lever
B. Fasten
C. Loosen
WHIA0103E
Revision: May 2010 2011 Versa
Page 3488 of 3787
PG-68
< SERVICE INFORMATION >
ELECTRICAL UNITS
ELECTRICAL UNITS
Terminal ArrangementINFOID:0000000005928359
LKIA0810E
Revision: May 20102011 Versa
Page 3489 of 3787
STANDARDIZED RELAYPG-69
< SERVICE INFORMATION >
C
DE
F
G H
I
J
L
M A
B
PG
N
O P
STANDARDIZED RELAY
DescriptionINFOID:0000000005928360
NORMAL OPEN, NORMAL CLOS ED AND MIXED TYPE RELAYS
Relays can mainly be divided into three types: normal open, normal closed and mixed type relays.
TYPE OF STANDARDIZED RELAYS
SEL881H
SEL882H
1M1 Make 2M2 Make
1T 1 Transfer 1M·1B1 Make 1 Break
Revision: May 2010 2011 Versa
Page 3490 of 3787
PG-70
< SERVICE INFORMATION >
STANDARDIZED RELAY
WKIA0253E
Revision: May 20102011 Versa
Trending: diagnostic menu, check oil, clock, fuel tank capacity, brake, ABS, fog light bulb