engine NISSAN NOTE 2016 Service Repair Manual
[x] Cancel search | Manufacturer: NISSAN, Model Year: 2016, Model line: NOTE, Model: NISSAN NOTE 2016Pages: 3641, PDF Size: 28.72 MB
Page 1414 of 3641
![NISSAN NOTE 2016 Service Repair Manual P0420 THREE WAY CATALYST FUNCTIONEC-287
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Diagnosis ProcedureINFOID:0000000012431489
1.CHECK EXHAUST SYSTEM
Visually check exhaust tube NISSAN NOTE 2016 Service Repair Manual P0420 THREE WAY CATALYST FUNCTIONEC-287
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Diagnosis ProcedureINFOID:0000000012431489
1.CHECK EXHAUST SYSTEM
Visually check exhaust tube](/img/5/57363/w960_57363-1413.png)
P0420 THREE WAY CATALYST FUNCTIONEC-287
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Diagnosis ProcedureINFOID:0000000012431489
1.CHECK EXHAUST SYSTEM
Visually check exhaust tubes and muffler for dent.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace.
2.CHECK EXHAUST GAS LEAK
1. Start engine and run it at idle.
2. Listen for an exhaust gas leak before the three way catalyst (manifold).
Is exhaust gas leak detected?
YES >> Repair or replace.
NO >> GO TO 3.
3.CHECK INTAKE AIR LEAK
Listen for an intake air leak after the mass air flow sensor.
Is intake air leak detected?
YES >> Repair or replace.
NO >> GO TO 4.
4.CHECK IGNITION TIMI NG AND IDLE SPEED
Check the following items. Refer to EC-133, "
Work Procedure".
For specification, refer to EC-478, "
Ignition Timing"
For specification, refer to EC-478, "Idle Speed".
Is the inspection result normal?
YES >> GO TO 5.
NO >> Follow the EC-133, "
Work Procedure".
5.CHECK FUEL INJECTOR
1. Stop engine and then turn ignition switch ON.
2. Check the voltage between ECM harness connector and ground.
PBIB1216E
Cylinder ECM
Vol tag e
No. Front / Rear +
−
Connector Terminal Connector Terminal
1
Front
F1031
E16 108 Battery voltage
23
0
32 9
42 5
1
Rear 12
22 0
31 6
42 4
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1415 of 3641
![NISSAN NOTE 2016 Service Repair Manual EC-288
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0420 THREE WAY CATALYST FUNCTION
Is the inspection result normal?
YES >> GO TO 6.
NO >> Perform
EC-446, "
Diagnosis Procedure".
6.CHECK FUNCTION OF IGNITION NISSAN NOTE 2016 Service Repair Manual EC-288
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0420 THREE WAY CATALYST FUNCTION
Is the inspection result normal?
YES >> GO TO 6.
NO >> Perform
EC-446, "
Diagnosis Procedure".
6.CHECK FUNCTION OF IGNITION](/img/5/57363/w960_57363-1414.png)
EC-288
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0420 THREE WAY CATALYST FUNCTION
Is the inspection result normal?
YES >> GO TO 6.
NO >> Perform
EC-446, "
Diagnosis Procedure".
6.CHECK FUNCTION OF IGNITION COIL-I
CAUTION:
Do the following procedure in the place where ventilation is good without the combustible.
1. Turn ignition switch OFF.
2. Remove fuel pump fuse in IPDM E/R to release fuel pressure. NOTE:
Do not use CONSULT to release fuel pressure, or fuel pressure applies again during the following proce-
dure.
3. Start engine.
4. After engine stalls, crank it two or three times to release all fuel pressure.
5. Turn ignition switch OFF.
6. Remove all ignition coil harness connectors to avoi d the electrical discharge from the ignition coils.
7. Remove ignition coil and spark plug of the cylinder to be checked.
8. Crank engine for 5 seconds or more to remove combustion gas in the cylinder.
9. Connect spark plug and harness connector to ignition coil.
10. Fix ignition coil using a rope etc. with gap of 13 - 17 mm (0.52 - 0.66 in) between the edge of the spark plug and grounded metal
portion as shown in the figure.
11. Crank engine for about 3 seconds, and check whether spark is
generated between the spark plug and the grounded metal por-
tion.
CAUTION:
• Do not approach to the spar k plug and the ignition coil
within 50 cm (19.7 in). Be careful not to get an electrical
shock while checking, because the electrical discharge
voltage becomes 20 kV or more.
• It might cause to damage the igni tion coil if the gap of more than 17 mm (0.66 in) is taken.
NOTE:
When the gap is less than 13 mm (0.52 in), the sp ark might be generated even if the coil is mal-
functioning.
Is the inspection result normal?
YES >> GO TO 10.
NO >> GO TO 7.
7.CHECK FUNCTION OF IGNITION COIL-II
1. Turn ignition switch OFF.
2. Disconnect spark plug and connect a known-good spark plug.
3. Crank engine for about 3 seconds, and recheck whether spark is generated between the spark plug and the grounded metal portion.
Is the inspection result normal?
YES >> GO TO 8.
NO >> Check ignition coil, power transistor and their circuits. Refer to EC-451, "
Diagnosis Procedure".
8.CHECK SPARK PLUG Spark should be generated.
JMBIA0066GB
Spark should be generated.
Revision: August 2015
2016 Versa Note
cardiagn.com
Page 1416 of 3641
![NISSAN NOTE 2016 Service Repair Manual P0420 THREE WAY CATALYST FUNCTIONEC-289
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Check the initial spark plug for fouling, etc.
Is the inspection result normal?
YES >> Replac NISSAN NOTE 2016 Service Repair Manual P0420 THREE WAY CATALYST FUNCTIONEC-289
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Check the initial spark plug for fouling, etc.
Is the inspection result normal?
YES >> Replac](/img/5/57363/w960_57363-1415.png)
P0420 THREE WAY CATALYST FUNCTIONEC-289
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Check the initial spark plug for fouling, etc.
Is the inspection result normal?
YES >> Replace spark plug(s) with standard type one(s). For
spark plug type, refer to EM-117, "
Spark Plug".
NO >> Repair or clean spark plug. Then GO TO 9
9.CHECK FUNCTION OF IGNITION COIL-III
1. Reconnect the initial spark plugs.
2. Crank engine for about 3 seconds, and recheck whether spark is generated between the spark plug and the grounded portion.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace spark plug(s) with standard type one(s). For spark plug type, refer to EM-117, "
Spar k
Plug".
10.CHECK FUEL INJECTOR
1. Turn ignition switch OFF.
2. Remove fuel injector assembly. Refer to EM-40, "
Removal and Installation".
Keep fuel hose and all fuel injectors connected to fuel tube.
3. Disconnect all ignition coil harness connectors.
4. Reconnect all fuel injector harness connectors disconnected.
5. Turn ignition switch ON.
Does fuel drip from fuel injector?
YES >> GO TO 11.
NO >> Replace the fuel injector(s) from which fuel is dripping. Refer to EM-40, "
Removal and Installa-
tion".
11 .CHECK INTERMITTENT INCIDENT
Refer to GI-42, "
Intermittent Incident".
Is the trouble fixed?
YES >> INSPECTION END
NO >> Replace three way catalyst assembly. Refer to EX-5, "
Exploded View".
SEF156I
Spark should be generated.
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1418 of 3641
![NISSAN NOTE 2016 Service Repair Manual P0441 EVAP CONTROL SYSTEMEC-291
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
2.PERFORM DTC CONFIRMATION PROCEDURE-I
WITH CONSULT
TESTING CONDITION:
Always perform test at a tempe NISSAN NOTE 2016 Service Repair Manual P0441 EVAP CONTROL SYSTEMEC-291
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
2.PERFORM DTC CONFIRMATION PROCEDURE-I
WITH CONSULT
TESTING CONDITION:
Always perform test at a tempe](/img/5/57363/w960_57363-1417.png)
P0441 EVAP CONTROL SYSTEMEC-291
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
2.PERFORM DTC CONFIRMATION PROCEDURE-I
WITH CONSULT
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41° F) or more.
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Turn ignition switch OFF and wait at least 10 seconds.
5. Start engine and let it idle for at least 70 seconds.
6. Select “PURG FLOW P0441” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode of
“ENGINE” using CONSULT.
7. Touch “START”.
Is
“COMPLETED” displayed on CONSULT screen?
YES >> GO TO 4.
NO >> GO TO 3.
3.PERFORM DTC CONFIRMATION PROCEDURE-II
When the following conditions are met, “TESTING” will be displayed on the CONSULT screen. Maintain the
conditions continuously until “TESTING” changes to “COMPLETED”. (It will take at least 35 seconds.)
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If “TESTING” does not change for a long time, retry from step 2.
Is
“COMPLETED” displayed on CONSULT screen?
YES >> GO TO 4.
NO >> Perform DTC CONFIRMATION PROCEDURE again. GO TO 2.
4.PERFORM DTC CONFIRMATION PROCEDURE-III
Touch “SELF-DIAG RESULTS”.
Which is displayed on CONSULT screen?
OK >> INSPECTION END
NG >> Proceed to EC-292, "
Diagnosis Procedure".
5.PERFORM COMPONENT FUNCTION CHECK
WITH GST
Perform component function check. Refer to EC-291, "
Component Function Check".
NOTE:
Use component function check to check the overall m onitoring function of the EVAP control system purge flow
monitoring. During this check, a 1s t trip DTC might not be confirmed.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Proceed to EC-292, "
Diagnosis Procedure".
Component Function CheckINFOID:0000000012431491
1.PERFORM COMPONENT FUNCTION CHECK
1. Lift up drive wheels.
2. Start engine (VDC switch OFF) and warm it up to normal operating temperature.
3. Turn ignition switch OFF and wait at least 10 seconds.
Selector lever Suitable position
VHCL SPEED SE 32 - 120 km/h (20 - 75 MPH)
ENG SPEED 500 - 3,800 rpm
B/FUEL SCHDL 1.0 - 10 msec
COOLAN TEMP/S More than 0°C (32 °F)
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1419 of 3641
![NISSAN NOTE 2016 Service Repair Manual EC-292
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0441 EVAP CONTROL SYSTEM
4. Start engine and wait at least 70 seconds.
5. Set voltmeter probes to ECM harness connector terminals as per the following.
6. Che NISSAN NOTE 2016 Service Repair Manual EC-292
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0441 EVAP CONTROL SYSTEM
4. Start engine and wait at least 70 seconds.
5. Set voltmeter probes to ECM harness connector terminals as per the following.
6. Che](/img/5/57363/w960_57363-1418.png)
EC-292
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0441 EVAP CONTROL SYSTEM
4. Start engine and wait at least 70 seconds.
5. Set voltmeter probes to ECM harness connector terminals as per the following.
6. Check EVAP control system pressure sensor value at idle speed and note it.
7. Establish and maintain the following conditions for at least 1 minute.
8. Verify that EVAP control system pressure sensor value stays 0.1 V less than the value at idle speed (mea-
sured at step 6) for at least 1 second.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Proceed to EC-292, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000012431492
1.CHECK EVAP CANISTER
1. Turn ignition switch OFF.
2. Check EVAP canister for cracks.
Is the inspection result normal?
YES-1 >> With CONSULT: GO TO 2.
YES-2 >> Without CONSULT: GO TO 3.
NO >> Replace EVAP canister. Refer to FL-14, "
Removal and Installation".
2.CHECK PURGE FLOW
WITH CONSULT
1. Disconnect vacuum hose connected to EVAP canister purge volume control solenoid valve at EVAP ser-
vice port.
2. Start engine and let it idle.
3. Select “PURG VOL CONT/V” in “ACTIVE TEST” mode of “ENGINE” using CONSULT.
4. Touch “Qd” and “Qu” on CONSULT screen to adjust “PURG VOL CONT/V” opening and check vacuum existence.
Is the inspection result normal?
YES >> GO TO 7.
NO >> GO TO 4.
3.CHECK PURGE FLOW
WITHOUT CONSULT
1. Start engine and warm it up to normal operating temperature.
2. Stop engine.
ECM
Connector +–
Te r m i n a l
F11 4368
Air conditioner switch ON
Headlamp switch ON
Rear window defogger switch ON
Engine speed Approx. 3,000 rpm
Gear position Any position other than P, N or R
PURG VOL CONT/V Vacuum
100% Existed
0% Not existed
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1420 of 3641
![NISSAN NOTE 2016 Service Repair Manual P0441 EVAP CONTROL SYSTEMEC-293
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
3. Disconnect vacuum hose connected to EVAP canister
purge volume control solenoid valve at EVAP ser NISSAN NOTE 2016 Service Repair Manual P0441 EVAP CONTROL SYSTEMEC-293
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
3. Disconnect vacuum hose connected to EVAP canister
purge volume control solenoid valve at EVAP ser](/img/5/57363/w960_57363-1419.png)
P0441 EVAP CONTROL SYSTEMEC-293
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
3. Disconnect vacuum hose connected to EVAP canister
purge volume control solenoid valve at EVAP ser-
vice port and install vacuum gauge. For the lo cation of EVAP service port, refer to FL-14, "
Exploded
View".
4. Start engine and let it idle. Never depress accelerator pedal even slightly.
5. Check vacuum gauge indication before 60 seconds pass after starting engine.
6. Rev engine up to 2,000 rpm after 100 seconds pass after starting engine.
Is the inspection result normal?
YES >> GO TO 7.
NO >> GO TO 4.
4.CHECK EVAP PURGE LINE
1. Turn ignition switch OFF.
2. Check EVAP purge line for improper connection or disconnection. Refer to EC-40, "
EVAPORATIVE EMISSION SYSTEM : System Diagram".
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair EVAP purge line.
5.CHECK EVAP PURGE HOSE AND PURGE PORT
1. Disconnect purge hoses connected to EVAP service port (A )
and EVAP canister purge volume control solenoid valve ( B).
2. Blow air into each hose and EVAP purge port ( C).
3. Check that air flows freely.
Is the inspection result normal?
YES-1 >> With CONSULT: GO TO 6.
YES-2 >> Without CONSULT: GO TO 7.
NO >> Repair or clean hoses and/or purge port.
6.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
WITH CONSULT
1. Start engine.
2. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode of “ENGINE” using CONSULT. Check that
engine speed varies according to the valve opening.
Does engine speed vary according to the valve opening?
YES >> GO TO 8.
NO >> GO TO 7. Vacuum should not exist.
Vacuum should exist.
SEF367U
SEF368U
Revision: August 2015
2016 Versa Note
cardiagn.com
Page 1422 of 3641
![NISSAN NOTE 2016 Service Repair Manual P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-295
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0443 EVAP CANISTER PURGE VOLU
ME CONTROL SOLENOID VALVE
DTC LogicINFO NISSAN NOTE 2016 Service Repair Manual P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-295
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0443 EVAP CANISTER PURGE VOLU
ME CONTROL SOLENOID VALVE
DTC LogicINFO](/img/5/57363/w960_57363-1421.png)
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-295
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0443 EVAP CANISTER PURGE VOLU
ME CONTROL SOLENOID VALVE
DTC LogicINFOID:0000000012431493
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next test.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
• Perform DTC CONFIRMATION PROCEDURE when the fu el is between 1/4 and 3/4 full, and vehicle is
placed on flat level surface.
• Always perform test at a temperature of 5 to 60 °C (41 to 140 °F).
• Cool the vehicle so that engi ne coolant temperature becomes same level as ambient temperature.
Do you have CONSULT
YES >> GO TO 2.
NO >> GO TO 4.
2.PERFORM DTC CONFIRMATION PROCEDURE A
With CONSULT
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode of “ENGINE” using CONSULT.
3. Check that the following condition are met. FUEL T/TMP SE: 0 - 35 °C (32 - 95° F)
4. Start engine and wait at least 60 seconds.
5. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-296, "Diagnosis Procedure".
NO >> GO TO 3.
3.PERFORM DTC CONFIRMATION PROCEDURE B
With CONSULT
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “PURG VOL CN/V P1444” of “EVAPORATI VE SYSTEM” in “DTC WORK SUPPORT” mode of
“ENGINE” using CONSULT.
5. Touch “START”.
6. Start engine and let it idle until “TESTING” on CONSUL T changes to “COMPLETED”. (It will take approxi-
mately 10 seconds.)
If “TESTING” is not displayed afte r 5 minutes, retry from step 2.
7. Touch “SELF-DIAG RESULT”.
DTC No. CONSULT screen terms
(Trouble diagnosis content) DTC detecting condition
Possible cause
P0443 PURG VOLUME CONT/V
(EVAP canister purge volume
control solenoid valve) A
The canister purge flow is detected during
the vehicle is stopped while the engine is
running, even when EVAP canister purge
volume control solenoid valve is completely
closed. • EVAP control system pressure sensor
• EVAP canister purge volume control
solenoid valve
(The valve is stuck open.)
• EVAP canister vent control valve
• EVAP canister
• Hoses (Hoses are connected incorrectly or
clogged.)
B The canister purge flow is detected during
the specified driving conditions, even when
EVAP canister purge volume control sole-
noid valve is completely closed.
Revision: August 2015
2016 Versa Note
cardiagn.com
Page 1423 of 3641
![NISSAN NOTE 2016 Service Repair Manual EC-296
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Which is displayed on CONSULT?
OK >> INSPECTION END
NG >> Proceed to
EC-296, "
Diagnosis Procedure".
4 NISSAN NOTE 2016 Service Repair Manual EC-296
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Which is displayed on CONSULT?
OK >> INSPECTION END
NG >> Proceed to
EC-296, "
Diagnosis Procedure".
4](/img/5/57363/w960_57363-1422.png)
EC-296
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Which is displayed on CONSULT?
OK >> INSPECTION END
NG >> Proceed to
EC-296, "
Diagnosis Procedure".
4.PERFORM DTC CONFIRMATION PROCEDURE A
With GST
1. Turn ignition switch ON.
2. Check the voltage between ECM harness connector and ground.
3. Start engine and wait at least 60 seconds.
4. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-296, "Diagnosis Procedure".
NO >> GO TO 5.
5.PERFORM DTC CONFIRMATION PROCEDURE
With GST
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 20 seconds.
4. Check 1st trip DTC.
Is 1st trip DTC detected?
YES >> Proceed to EC-296, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000012431494
1.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check the voltage between EVAP canister purge volume control solenoid valve harness connector and ground.
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 2.
2.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector.
3. Check the continuity between EVAP canister purge volume control solenoid valve harness connector and IPDM E/R harness connector.
ECM Ground Voltage
Connector Terminal
F11 43 Ground 3.1 - 4.0 V
EVAP canister purge volume control solenoid valve GroundVoltage
Connector Terminal
F22 1Ground Battery voltage
EVAP canister purge volume
control solenoid valve IPDM E/R
Continuity
Connector Terminal Connector Terminal
F22 1E44 11 Existed
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1424 of 3641
![NISSAN NOTE 2016 Service Repair Manual P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-297
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
4. Also check harness for short to ground.
Is the inspection result no NISSAN NOTE 2016 Service Repair Manual P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-297
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
4. Also check harness for short to ground.
Is the inspection result no](/img/5/57363/w960_57363-1423.png)
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-297
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
4. Also check harness for short to ground.
Is the inspection result normal?
YES >> Perform the trouble diagnosis for power supply circuit.
NO >> Repair or replace error-detected parts.
3.CHECK EVAP CANISTER PURGE VOLUME
CONTROL SOLENOID VALVE GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between EVAP canister pur ge volume control solenoid valve harness connector and
ECM harness connector.
4. Also check harness for short to power.
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair or replace error-detected parts.
4.CHECK EVAP CONTRO L SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
2. Check connectors for water.
Is the inspection result normal?
YES >> GO TO 5.
NO >> Replace EVAP control system pressure sensor. Refer to FL-19, "
Removal and Installation".
5.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check the EVAP control system pressure sensor. Refer to EC-298, "
Component Inspection".
Is the inspection result normal?
YES-1 >> With CONSULT: GO TO 6.
YES-2 >> Without CONSULT: GO TO 7.
NO >> Replace EVAP control system pressure sensor. Refer to FL-19, "
Removal and Installation".
6.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT
1. Turn ignition switch OFF.
2. Reconnect harness connectors disconnected.
3. Start engine.
4. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode of “ENGINE” using CONSULT. Check that
engine speed varies according to the valve opening.
Is the inspection result normal?
YES >> GO TO 8.
NO >> GO TO 7.
7.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
Check the EVAP canister purge volume control solenoid valve. Refer to EC-298, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 8.
NO >> Replace EVAP canister purge volume control solenoid valve. Refer to FL-14, "
Exploded View".
8.CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EV AP canister vent control valve.
2. Check the rubber tube for clogging.
EVAP canister purge volume
control solenoid valve ECM
Continuity
Connector Terminal Connector Terminal
F22 2F10 9 Existed
Water should not exist.
Revision: August 2015 2016 Versa Note
cardiagn.com
Page 1425 of 3641
![NISSAN NOTE 2016 Service Repair Manual EC-298
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Is the inspection result normal?
YES >> GO TO 9.
NO >> Clean the rubber tube using an air blower.
9.CHE NISSAN NOTE 2016 Service Repair Manual EC-298
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Is the inspection result normal?
YES >> GO TO 9.
NO >> Clean the rubber tube using an air blower.
9.CHE](/img/5/57363/w960_57363-1424.png)
EC-298
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Is the inspection result normal?
YES >> GO TO 9.
NO >> Clean the rubber tube using an air blower.
9.CHECK EVAP CANISTER VENT CONTROL VALVE
Check the EVAP canister vent control valve. Refer to EC-304, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 10.
NO >> Replace EVAP canister vent control valve. Refer to FL-17, "
Removal and Installation".
10.CHECK IF EVAP CANISTER IS SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor attached.
2. Check if water will drain from EVAP canister.
Does water drain from the EVAP canister?
YES >> GO TO 11.
NO >> Check intermittent incident. Refer to GI-42, "
Intermittent
Incident".
11 .CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 1.6 kg (3.5 lb).
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI-42, "Intermittent Incident".
NO >> GO TO 12.
12.DETECT MALFUNCTIONING PART
Check the following.
• EVAP canister for damage
• EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
>> Repair hose or replace EVAP canister. Refer to FL-14, "
Removal and Installation".
Component InspectionINFOID:0000000012431495
1.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT
1. Turn ignition switch OFF.
2. Reconnect all harness connectors disconnected.
3. Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.
4. Start engine.
5. Select “PURG VOL CONT/V” in “ACTIVE TEST” mode of “ENGINE” using CONSULT.
PBIB1213E
Revision: August 2015 2016 Versa Note
cardiagn.com