battery NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual PATROL 1998 Y61 / 5.G NISSAN NISSAN https://www.carmanualsonline.info/img/5/616/w960_616-0.png NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual

Page 1 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual ELECTRICAL SYSTEM
SECTION
EL
When you read wiring diagrams:
+Read GI section, ``HOW TO READ WIRING DIAGRAMS.
When you perform trouble diagnoses, read GI section, ``HOW TO FOLLOW FLOW
CHART IN TROUBL

Page 10 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Wiring Diagram Ð POWER Ð
BATTERY POWER SUPPLY Ð IGNITION SW. IN ANY POSITION
TEL479A
POWER SUPPLY ROUTING
EL-6

Page 41 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual CAUTION:
If it becomes necessary to start the engine with a booster bat-
tery and jumper cables,
a. Use a 12-volt booster battery.
b. After connecting battery cables, ensure that they are
tightly clam

Page 42 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual +Remove the cell plug using a suitable tool.
+Add distilled water up to the MAX level.
SULPHATION
A battery will be completely discharged if it is left unattended
for a long time and the speci®c grav

Page 43 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual 2. Convert into speci®c gravity at 20ÉC (68ÉF).
Example:
+When electrolyte temperature is 35ÉC (95ÉF) and speci®c grav-
ity of electrolyte is 1.230, converted speci®c gravity at 20ÉC
(68ÉF) i

Page 44 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Battery Test and Charging Chart
Chart I
VISUAL INSPECTION
+Check battery case for cracks or bends.
+Check battery terminals for damage.
+If the difference between the max. and min. electrolyte level i

Page 45 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Chart II
CAPACITY TEST
Test using battery checker.Test using load tester.
Follow manufacturers instruc-
tions to check and determine
if battery is serviceable.
OK NGRead load tester voltage
when spec

Page 46 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual A: SLOW CHARGE
Determine initial charging current from speci®c gravity refer-
ring to Fig. 2.
+Charge battery.
+Check charging voltage 30 minutes after starting the bat-
tery charge.
12 to 15 volts
O

Page 47 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual B: STANDARD CHARGE
Determine initial charging current from
speci®c gravity, referring to Fig. 4.
Charge battery for 8 hours.
CHECKING SPECIFIC GRAVITY
Refer to ``Speci®c Gravity Check.
Conduct add

Page 48 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual C: QUICK CHARGE
Determine initial charging current setting and charg-
ing time from speci®c gravity, referring to Fig. 6.
Charge battery.
Go to ``CAPACITY TEST.Fig. 6 INITIAL CHARGING CURRENT SETTI
Page:   1-10 11-20 21-30 31-40 41-50 ... 50 next >