charging NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual PATROL 1998 Y61 / 5.G NISSAN NISSAN https://www.carmanualsonline.info/img/5/616/w960_616-0.png NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual

Page 1 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual ELECTRICAL SYSTEM
SECTION
EL
When you read wiring diagrams:
+Read GI section, ``HOW TO READ WIRING DIAGRAMS.
When you perform trouble diagnoses, read GI section, ``HOW TO FOLLOW FLOW
CHART IN TROUBL

Page 42 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual +Remove the cell plug using a suitable tool.
+Add distilled water up to the MAX level.
SULPHATION
A battery will be completely discharged if it is left unattended
for a long time and the speci®c grav

Page 44 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Battery Test and Charging Chart
Chart I
VISUAL INSPECTION
+Check battery case for cracks or bends.
+Check battery terminals for damage.
+If the difference between the max. and min. electrolyte level i

Page 45 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Chart II
CAPACITY TEST
Test using battery checker.Test using load tester.
Follow manufacturers instruc-
tions to check and determine
if battery is serviceable.
OK NGRead load tester voltage
when spec

Page 46 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual A: SLOW CHARGE
Determine initial charging current from speci®c gravity refer-
ring to Fig. 2.
+Charge battery.
+Check charging voltage 30 minutes after starting the bat-
tery charge.
12 to 15 volts
O

Page 47 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual B: STANDARD CHARGE
Determine initial charging current from
speci®c gravity, referring to Fig. 4.
Charge battery for 8 hours.
CHECKING SPECIFIC GRAVITY
Refer to ``Speci®c Gravity Check.
Conduct add

Page 48 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual C: QUICK CHARGE
Determine initial charging current setting and charg-
ing time from speci®c gravity, referring to Fig. 6.
Charge battery.
Go to ``CAPACITY TEST.Fig. 6 INITIAL CHARGING CURRENT SETTI

Page 50 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Trouble Diagnoses
If any abnormality is found, immediately disconnect battery negative terminal.
Starter does not stop.cReplace magnetic switch.
Engine does not start.
Does engine turn by cranking?
No

Page 56 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Wiring Diagram Ð CHARGE Ð
YEL782A
CHARGING SYSTEM
EL-52

Page 57 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Trouble Diagnoses
Before conducting an alternator test, make sure that the battery is fully charged. A 30-volt voltmeter and suit-
able test probes are necessary for the test. The alternator can be ch