CHECKS
109
Tilt the handle on the left-hand side
under the fascia to the right.
Lift the catch and raise the bonnet. Secure the strut
to hold the bonnet
open.
Before closing the
bonnet, replace the
strut in its housing.
RUNNING OUT OF FUEL
(DIESEL)
If you should run out of fuel, it is nec-
essary to re-prime the circuit.
The repriming pump, the degas
screw and the transparent pipe are
located under the bonnet (see corre-
sponding drawing):
OPENING THE BONNET
From inside
From outside
Bonnet strut
To close
Lower the bonnet and release it at
the end of its travel.
Check that the bonnet is properly
locked.
1.6 litre HDI 16V engine
- i l l t h e f u e l t a n k w i t h a t l e a s t i v e
litres of diesel,
- unclip the style cover to access the repriming pump,
- squeeze and release the manual repriming pump until fuel appears
in the transparent pipe with the
green connector,
- operate the starter until the engine starts.
2 litre HDI 16V engine
- i l l t h e f u e l t a n k w i t h a t l e a s t i v e litres of diesel,
- unclip the style cover to access the repriming pump,
- unscrew the degas screw,
- squeeze and release the manual repriming pump until diesel is
seen escaping via the degas
screw,
- retighten the degas screw,
- operate the starter until the engine starts.