ANTI-LOCK BRAKING SYSTEM
Fault finding - Interpretation of faults
38C
38C - 33V2 MR-372-J84-38C000$396_eng.mif
BOSCH ABS 8.0
Vdiag No.: 0C, 0D, 0E, 0F
DF066
PRESENT
OR
STOREDINJECTION MULTIPLEX SIGNAL ABSENT
1.DEF : Carry out the multiplex network fault finding procedure
NOTESSpecial notes:
Although stored in the computer, the fault is not due to ABS components but injection
components. Run fault finding on the injection system.
Note:
The injection computer does not always store these transient faults as quickly as the
ABS computer. If no fault is stored in the injection computer, start the engine; if there
is no fault present, contact the Techline. After solving the injection system problem,
erase the faults from the ABS computer memory.
The multiplex injection signal is sent to the ABS system via the Protection and
Switching Unit.
Priorities when dealing with a number of faults:
Deal with faults DF152 and DF153 first, whether they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present when the engine is started up.
Check the condition and correct locking of the blue PEH connector on the UPC (Vdiag 44) or the grey CT1
connector of the UPC (Vdiag 48).
Carry out a multiplex network test and check the injection system with the diagnostic tool.
If the fault is still present, contact the Techline.
AFTER REPAIRClear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
ABS8.0_V0C_DF066 /ABS8.0_V0D_DF066/ABS8.0_V0E_DF066/ABS8.0_V0F_DF066 ABS 8.0X84 4.0
Page 38 of 64
ANTI-LOCK BRAKING SYSTEM
Fault finding - Interpretation of faults
38C
38C - 38V2 MR-372-J84-38C000$396_eng.mif
BOSCH ABS 8.0
Vdiag No.: 0C, 0D, 0E, 0F
DF152
STORED
MULTIPLEX NETWORK (BUS OFF)
1.DEF : Carry out the multiplex network fault finding procedure
NOTESSpecial notes:
If several computers are affected by a similar multiplex network fault, contact the
Techline to check the cases previously noted first.
Conditions for applying the fault finding procedure to stored faults:
Apply the fault finding procedure as below.
If no other computer has detected a multiplex network fault but only the absence of ABS frames, carry out the
following checks:
–check the connection and condition (corrosion, bent terminal, crimping, etc.) of the computer connections
(tracks 15 and 26). Repair if necessary.
Check the connection (locking) and condition (corrosion, bent terminals, crimping, etc.) of the blue PEH connector
on the UPC (Vdiag 44) or the grey CT1 connector of the UPC (Vdiag 48).
Repair if necessary.
Check the insulation, continuity and absence of interference resistance between:
Computer connector track 15 Track 7 of the blue PEH connector of the Vdiag 44 UPC
Track 2 of the grey CT1 connector of the Vdiag 48 UPC
Computer connector track 26 Track 11 of the blue PEH connector of the Vdiag 44 UPC
Track 3 of the blue CT1 connector of the Vdiag 48 UPC
Also check the insulation between these two connections. Repair or replace the wiring if necessary.
If the problem is still present, run fault finding on the multiplex network.
AFTER REPAIRClear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
ABS8.0_V0C_DF152 /ABS8.0_V0D_DF152/ABS8.0_V0E_DF152/ABS8.0_V0F_DF152 ABS 8.0X84 4.0
Page 40 of 64
ANTI-LOCK BRAKING SYSTEM
Fault finding - Interpretation of faults
38C
38C - 40V2 MR-372-J84-38C000$396_eng.mif
BOSCH ABS 8.0
Vdiag No.: 0C, 0D, 0E, 0F
DF186
PRESENT
OR
STOREDNO INSTRUMENT PANEL MULTIPLEX SIGNAL
NOTESSpecial notes:
Even though it is stored in the computer, this fault does not cause the warning lights to
come on or a fault message. Using the diagnostic tool, run fault finding on the
instrument panel.
Note:
Once the fault in the instrument panel system has been repaired, clear the ABS
computer fault memory.
The multiplex signal from the instrument panel is sent to the ABS via the Protection and
Switching Unit.
Priorities when dealing with a number of faults:
Deal with faults DF152 and DF153 first, whether they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present when the engine is started up.
Check the condition and correct locking of the blue PEH connector on the UPC (Vdiag 44) or the grey CT1
connector of the UPC (Vdiag 48).
Carry out a multiplex network test.
If the fault is still present, perform fault finding on the instrument panel and repair accordingly.
If the fault is still present, contact the Techline.
AFTER REPAIRClear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.