relay RENAULT SCENIC 2008 J84 / 2.G Gas Injection LPG 3000 Owner's Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2008, Model line: SCENIC, Model: RENAULT SCENIC 2008 J84 / 2.GPages: 107, PDF Size: 0.31 MB
Page 77 of 107

17C-77
MR-372-J84-17C000$590.mif
V2
17C
GAS INJECTION
Fault finding - Interpretation of statuses
ET022
WAITING FOR LPG CONDITIONS
YES
NO
IMPORTANT
For any operation on a component of the LPG supply circuit, consult the safety instructions (see 17D,
LPG injection, Introduction, Safety instructions for all operations).
NOTESThere must be no present or stored faults.
Ignition on, engine stopped.
Status ET022 indicates YES for a variable period during which the computer checks that the LPG system is
operating correctly.
Variable duration depending on:
–ET100 LPG system ready,
–PR002 Coolant temperature,
–PR103 Air temperature,
–PR113 LPG temperature.
Apply the interpretation of faults DF103 LPG expansion valve solenoid valve circuit and DF007 Main relay
circuit.
Manipulate the wiring harness between the LPG computer and the petrol computer until a change in status is
noted.
Check the insulation, continuity and the absence of interference resistance on the connections between:
For Mégane 2:
LPG computer track A1
LPG computer track A2
For Logan:
LPG computer track A1
LPG computer track A2track K3, connector B, petrol computer
track K4, connector B, petrol computer
track 25 of the fuel computer
track 26 of the fuel computer
Repair if necessary.
If the status is still not correct, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair.
GAZ3000_V08_ET022 / GAZ3000_V10_ET022
LPG 3000
Program No.
Vdiag No: 08/10
MR-372-J84-17C000$590.mif
Page 80 of 107

17C-80
MR-372-J84-17C000$590.mif
V2
GAS INJECTION
Fault finding - Interpretation of statuses
LPG 3000
Program No.
Vdiag No: 08/10
17C
ET095
LPG TO PETROL TRANSITION
YES
NO
NOTESThere must be no present or stored faults.
Ignition on, engine stopped.
Status ET095 indicates YES for a variable period during the transition from LPG to petrol mode.
Check that the fuel pump starts when petrol mode is entered.
Check that status ET025 Fuel pump becomes ACTIVE.
If the fuel pump does not start, check:
–the fuel pump cut-off relay (see DF024 Fuel pump cut-off relay circuit),
–the petrol computer (see 17B, Petrol injection).
Repair or replace the faulty components, if necessary.
If the status is still not correct, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair.
GAZ3000_V08_ET095 / GAZ3000_V10_ET095
Page 81 of 107

17C-81
MR-372-J84-17C000$590.mif
V2
GAS INJECTION
Fault finding - Interpretation of statuses
LPG 3000
Program No.
Vdiag No: 08/10
17C
ET096
PETROL TO LPG TRANSITION
YES
NO
IMPORTANT
For any operation on a component of the LPG supply circuit, consult the safety instructions (see 17D,
LPG injection, Introduction, Safety instructions for all operations).
NOTESThere must be no present or stored faults.
Ignition on, engine stopped.
Special note
The duration of the transition varies according to the outside temperature.
Status ET095 indicates YES for a variable period during the transition from LPG to petrol mode.
Check that the fuel pump starts when petrol mode is entered.
Check that status ET025 Fuel pump becomes ACTIVE.
If the fuel pump does not start, check:
–the fuel pump cut-off relay (see DF024 Fuel pump cut-off relay circuit),
–the petrol computer (see 17B, Petrol injection).
Repair or replace the faulty components, if necessary.
If the status is still not correct, contact the Techline.
AFTER REPAIRFollow the instructions to confirm the repair:
GAZ3000_V08_ET096 / GAZ3000_V10_ET096
Page 82 of 107

17C-82
MR-372-J84-17C000$590.mif
V2
GAS INJECTION
Fault finding - Interpretation of statuses
LPG 3000
Program No.
Vdiag No: 08/10
17C
ET100
LPG SYSTEM READY
YES
NO
IMPORTANT
For any operation on a component of the LPG supply circuit, consult the safety instructions (see 17D,
LPG injection, Introduction, Safety instructions for all operations).
NOTESThere must be no present or stored faults.
Ignition on, engine stopped.
Status ET100 indicates YES if no LPG fault is present.
Check:
–the LPG tank solenoid valve (see DF013 Tank solenoid valve circuit),
–the general relay (see DF007 Main relay circuit),
–the LPG expansion valve solenoid valve (see DF103 LPG expansion valve solenoid valve),
–the LPG pressure sensor (see DF092 Expansion valve downstream pressure sensor circuit),
–the LPG pressure in the tank (see DF031 LPG pressure downstream of expansion valve).
Repair or replace the faulty components, if necessary.
Check:
–the LPG filling hoses,
–the supply hoses upstream of the expansion valve,
–the expansion valve,
–the hoses downstream of the expansion valve.
Repair or replace the faulty components, if necessary.
If the status is still not correct, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair.
GAZ3000_V08_ET100 / GAZ3000_V10_ET100
Page 89 of 107

17C-89
MR-372-J84-17C000$767.mif
V2
17C
GAS INJECTION
Fault finding - Command summary table
Tool command Diagnostic tool title
RZ001Memory fault
AC005Fuel sender relay
AC011Fuel pump cut-out relay
AC015Tank solenoid valve
AC018Cylinder 4 injector
AC019Cylinder 3 injector
AC020Cylinder 2 injector
AC021Cylinder 1 injector
AC022Sequential actuator control
AC024LPG expansion valve solenoid valve
VP001Enter VIN
LPG 3000
Program No.
Vdiag No: 08/10
MR-372-J84-17C000$767.mif
Page 90 of 107

17C-90
MR-372-J84-17C000$826.mif
V2
17C
GAS INJECTION
Fault finding - Interpretation of commands
AC005
FUEL TANK SENDER RELAY
NOTESWith ignition on and engine stopped.
Switch on the ignition and run command AC005.
If the fuel sender relay does not click 10 times, carry out the fault finding procedure below.
Check the insulation, continuity and the absence of interference resistance on the connection between:
For Mégane 2:
LPG computer track E4
Fuel sender relay track B2
For Logan:
LPG computer track E4
Double relay control unit track B2Earth
Earth
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance on the connection between:
For Mégane 2:
Fuel sender relay track B3
For Logan:
Double relay control unit track B3track B5 of the fuel sender relay
track B5 of the fuel pump relay
Repair if necessary.
If the fault is still present, replace the fuel sender relay (see MR 364 Mechanics, 17D, LPG injection).
AFTER REPAIRRepeat the conformity check from the start.
GAZ3000_V08_AC005 / GAZ3000_V10_AC005
LPG 3000
Program No.
Vdiag No: 08/10
MR-372-J84-17C000$826.mif
Page 91 of 107

17C-91
MR-372-J84-17C000$826.mif
V2
GAS INJECTION
Fault finding - Interpretation of commands
LPG 3000
Program No.
Vdiag No: 08/10
17C
AC015
TANK SOLENOID VALVE
NOTESWith ignition on and engine stopped.
Switch on the ignition and run command AC015.
If the tank solenoid valve does not click ten times, carry out the fault finding procedure below.
Look for possible damage to the harness, and check the condition and connection of the LPG tank solenoid
valve and its connectors.
Repair if necessary.
Check the connection and condition of the LPG solenoid valve connector and its connections.
Replace the connector if necessary.
Check for +12 V on track 1 of the LPG tank relay and track C2 of the LPG computer.
Repair if necessary.
With the ignition on, check for earth on track 2 of the LPG tank solenoid valve relay.
If, with the ignition on, the computer does not control the LPG tank solenoid valve relay on track 2 through an
earth, contact the Techline.
–Check that the solenoid valve is supplied with +12 V by track E4 of the LPG computer.
If necessary, check the insulation, continuity and the absence of interference resistance on the connection
between:
For Mégane 2:
LPG computer track E4
For Logan:
LPG computer track E4track 2 of the LPG tank relay
track B2 of the double relay control unit
Repair if necessary.
AFTER REPAIRRepeat the conformity check from the start.
GAZ3000_V08_AC015 / GAZ3000_V10_AC015
Page 92 of 107

17C-92
MR-372-J84-17C000$826.mif
V2
GAS INJECTION
Fault finding - Interpretation of commands
LPG 3000
Program No.
Vdiag No: 08/10
17C
AC015
CONTINUED
–Check for +12 V on track 5 of the LPG tank relay.
If necessary, check the following connections for insulation from earth, continuity and absence of extraneous
resistance:
For Mégane 2:
LPG computer track E3
LPG tank solenoid valve track D
For Logan:
LPG computer track E3
LPG tank solenoid valve track 1track 5 of the LPG tank relay
track B5 of the double relay control unit
Repair if necessary.
Check for earth on track E (for Mégane 2) or on track 2 (for Logan) of the LPG tank solenoid valve.
Repair if necessary.
With the engine running, check that the LPG tank solenoid valve clicks when the LPG mode is selected.
If the fault is still present, replace the LPG tank solenoid valve (see MR 364 Mechanics, 17D, LPG
injection).
AFTER REPAIRRepeat the conformity check from the start.
Page 103 of 107

17C-103
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 3 The engine stalls when switched to LPG mode
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESCheck that there is LPG in the tank.
Check the condition of the air filter.
Replace the filter if necessary.
Check that the LPG supply pipes are not pinched or crushed.
Replace the faulty pipes if necessary.
Check the expansion valve cooling circuit (see MR 364 Mechanics, 17D, LPG injection, Expansion valve).
Repair the circuit if necessary.
Measure the resistance between tracks 1 and 2 of the injectors.
Replace the injectors if their resistance value at approximately 20°C is not between:
0.77 Ω < R < 1.43 Ω
Check the following connections for insulation from earth, continuity and absence of extraneous
resistance:
Main relay track 5
Main relay track 5
Main relay track 5
Main relay track 5track 1of injector 1
track 1of injector 2
track 1of injector 3
track 1of injector 4
Check the insulation from + 12 V, the continuity and the absence of interference resistance of
the connections between:
LPG computer track G3
LPG computer track G4
LPG computer track H2
LPG Computer track H3track 2 of injector 1
track 2 of injector 2
track 2 of injector 3
track 2 of injector 4
If necessary, repair the defective connections.
AFTER REPAIRCheck using the diagnostic tool.
GAZ3000_V08_ALP3 / GAZ3000_V10_ALP3
Page 104 of 107

17C-104
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 3
CONTINUED
Test the operation of the injectors.
Run commands AC018 Cylinder 4 injector, AC019 Cylinder 3 injector, AC020 Cylinder 2 injector
and AC021 Cylinder 1 injector.
Run the engine in petrol mode.
Disconnect the LPG tank connector and switch to LPG mode.
Check for + 12 Von track 1 of the LPG tank relay connector.
Repair if necessary.
Check for earth on track 2 of the LPG tank relay connector.
Repair if necessary.
Measure the resistance between tracks A4 and A5 (for Mégane 2) or tracks 1 and 2 (for Logan) of the LPG
tank solenoid valve.
Replace the solenoid valve if the resistance value is not approximately 12.6 Ω.
AFTER REPAIRCheck using the diagnostic tool.