air condition RENAULT SCENIC 2008 J84 / 2.G Gas Injection LPG 3000 Service Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2008, Model line: SCENIC, Model: RENAULT SCENIC 2008 J84 / 2.GPages: 107, PDF Size: 0.31 MB
Page 99 of 107
17C-99
MR-372-J84-17C000$944.mif
V2
17C
GAS INJECTION
Fault finding - Fault finding chart (ALP)
ALP 1 No dialogue with the computer
NOTESNone.
Check for a + 12 V battery feed on track H4 and a + 12 V after ignition feed (using the forced + after ignition
mode, see Introduction section) on track C2 of the LPG computer.
Repair if necessary.
Check the condition of the battery and the vehicle earths.
Repair if necessary.
Try the diagnostic tool on another vehicle.
–check the connection between the diagnostic tool and the diagnostic socket (lead in good condition),
–check fuse F5 (15 A) (for Mégane 2) and fuses F04 (10A) and F29 (15A) (for Logan).
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance on the connections between:
LPG computer track H1
LPG computer track G1
LPG computer track B4Earth
Earth
track 7 of the diagnostic socket
Repair if necessary.
Use the diagnostic socket to check the following tracks:
Track 1
Track 16
Tracks 4 and 5+ After ignition
+ Battery
Earth
Repair if necessary.
AFTER REPAIRCheck using the diagnostic tool.
GAZ3000_V08_ALP1 / GAZ3000_V10_ALP1
LPG 3000
Program No: AB
Vdiag No: 08/10
MR-372-J84-17C000$944.mif
Page 103 of 107
17C-103
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 3 The engine stalls when switched to LPG mode
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESCheck that there is LPG in the tank.
Check the condition of the air filter.
Replace the filter if necessary.
Check that the LPG supply pipes are not pinched or crushed.
Replace the faulty pipes if necessary.
Check the expansion valve cooling circuit (see MR 364 Mechanics, 17D, LPG injection, Expansion valve).
Repair the circuit if necessary.
Measure the resistance between tracks 1 and 2 of the injectors.
Replace the injectors if their resistance value at approximately 20°C is not between:
0.77 Ω < R < 1.43 Ω
Check the following connections for insulation from earth, continuity and absence of extraneous
resistance:
Main relay track 5
Main relay track 5
Main relay track 5
Main relay track 5track 1of injector 1
track 1of injector 2
track 1of injector 3
track 1of injector 4
Check the insulation from + 12 V, the continuity and the absence of interference resistance of
the connections between:
LPG computer track G3
LPG computer track G4
LPG computer track H2
LPG Computer track H3track 2 of injector 1
track 2 of injector 2
track 2 of injector 3
track 2 of injector 4
If necessary, repair the defective connections.
AFTER REPAIRCheck using the diagnostic tool.
GAZ3000_V08_ALP3 / GAZ3000_V10_ALP3
Page 105 of 107
17C-105
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 4 Idle speed faults
IMPORTANT
For any operation on a component of the LPG supply circuit, consult the safety instructions (see 17D,
LPG injection, Introduction, Safety instructions for all operations).
NOTESCheck that there is no fault in petrol mode.
Check that there is LPG in the tank.
Check that hoses are not blocked or pinched (especially after removal operations).
Repair the faulty component or components.
Check the condition of the air filter.
Replace the air filter if necessary.
Check the expansion valve cooling circuit (see MR 364 Mechanical, 17D, LPG injection, Expansion valve).
Repair the circuit if necessary.
Check the conformity of the spark plugs.
Replace the filter if necessary.
Test the operation of the injectors.
Run and interpret commands AC018 Cylinder 4 injector, AC019 Cylinder 3 injector, AC020 Cylinder 2
injector and AC021 Cylinder 1 injector.
AFTER REPAIRCheck using the diagnostic tool.
GAZ3000_V08_ALP4 / GAZ3000_V10_ALP4
Page 106 of 107
17C-106
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 5 Faults occurring while driving
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESCheck that there is no fault in petrol mode.
Check that hoses are not blocked or pinched (especially after removal operations).
Repair the faulty component or components.
Check the condition of the air filter.
Replace the air filter if necessary.
Check the expansion valve cooling circuit (see MR 364 Mechanical, 17D, LPG injection, Expansion valve).
Repair the circuit if necessary.
Check the conformity of the spark plugs.
Replace the filter if necessary.
Test the operation of the injectors.
Run and interpret commands AC018 Cylinder 4 injector, AC019 Cylinder 3 injector, AC020 Cylinder 2
injector and AC021 Cylinder 1 injector.
AFTER REPAIRCheck using the diagnostic tool.
GAZ3000_V08_ALP5 / GAZ3000_V10_ALP5
Page 107 of 107
17C-107
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 6 LPG leak
IMPORTANT
For any operation on a component of the LPG supply circuit, consult the safety instructions (see 17D,
LPG injection, Introduction, Safety instructions for all operations).
NOTESNone.
Open the plastic cover on the filler neck.
Check that the filler neck is in good condition.
Change the filler spigot if necessary.
Check that there are no leaks along the pipe that runs from the filler spigot to the LPG tank.
(Fill up with LPG to carry out this operation).
Repair the pipe if necessary.
AFTER REPAIRCheck using the diagnostic tool.
GAZ3000_V08_ALP6 / GAZ3000_V10_ALP6