warning RENAULT SCENIC 2009 J84 / 2.G Engine And Peripherals EDC16 Service Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: SCENIC, Model: RENAULT SCENIC 2009 J84 / 2.GPages: 273
Page 107 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -107V3 MR-372-J84-13B250$405.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF118
PRESENT
OR
STOREDEGR SOLENOID VALVE SERVO-CONTROL
1.DEF : Insufficient EGR valve flow
2.DEF : Excessive EGR valve flow
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
–the engine is started
–a road test
Special notes:
If the fault is present the EGR function is disabled.
If 2.DEF is present,
–the level 1 warning light is lit,
–there is smoke coming from the exhaust.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
Priority when dealing with a number of faults:
–DF272 EGR valve control circuit if it is present or stored.
IMPORTANT
If the EGR valve needs to be replaced to resolve the fault, use command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Check for continuity and the absence of interference resistance of the following connections:
Injection computer, brown 48-track connector B, track C2 Track 1 EGR valve connector
Injection computer brown 48-track connector B, track D2 Track 5 EGR valve connector
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check that there are no leaks on the EGR circuit (pipes pierced or damaged) and that the clamps are properly
tightened.
Measure the resistance of the EGR valve motor between tracks 1 and 5.
If the resistance measured is not between 1 Ω < X < 400 Ω at 20˚C, replace the EGR valve.
If the valve is jammed or irrevocably seized, replace the EGR valve.
Run command SC036 Reset programming and select EGR valve to reset the EGR valve offsets
(see Replacement of components).
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF118
Page 110 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-110V3 MR-372-J84-13B250$405.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF209
PRESENT
OR
STOREDEGR POSITION SENSOR CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Micro-breaks
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
–there is smoke coming from the exhaust,
–the EGR offset fault finding function is disabled,
–the OBD warning light will come on after three consecutive driving cycles (starting
+ 5 seconds + switching off the ignition and waiting 1 minute).
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
Priorities when dealing with a number of faults:
–DF012 Sensor supply voltage no. 2 if it is present or stored.
IMPORTANT
If the EGR valve needs to be replaced to resolve the fault, use command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This check enables the condition and the conformity of the engine wiring harness to be checked.
CO.0
NOTESNone.
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF209
Page 113 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-113V3 MR-372-J84-13B250$405.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF226
PRESENT
OR
STORED
DAMPER VALVE CIRCUIT
CC.1 : Short circuit to + 12 V
CC.0 : Short circuit to earth
CO : Open circuit
CC : Short circuit
1.DEF : Internal electronic fault
2.DEF : External fault finding
3.DEF : Values outside tolerances
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
–the engine is started,
–a road test,
–actuator command AC012 Damper valve;
–switching off the ignition and waiting for 1 minute.
Special notes:
If the fault is present:
–it is difficult or even impossible to start the vehicle,
–the engine stops noisily,
–the level 1 warning light is lit.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
CC.1
NOTESAfter any work is carried out on the damper valve, run SC036
Reinitialise programming and select Damper valve, then
switch off the ignition and wait 1 minute.
Check the damper valve connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity and insulation from the + 12 V feed of the following connection:
Earth Track 1 of the damper valve
Injection computer brown 48-track connector B, track J4 Track 3 of the damper valve
Injection computer brown 48-track connector B, track B2 Track 4 of the damper valve
Repair if necessary.
If the fault is still present, replace the damper valve.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF226
Page 118 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-118V3 MR-372-J84-13B250$405.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF272
PRESENT
OR
STOREDEGR VALVE CONTROL CIRCUIT
1.DEF : Valve jammed open
2.DEF : Valve jammed closed
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Special notes:
The EGR function is deactivated if several faults with DF226 Damper valve circuit are
present.
If 1.DEF is present,
–the level 1 warning light is lit,
–the vehicle performance is reduced,
–there is smoke coming from the exhaust.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity and the absence of interference resistance on the following connections:
Injection computer brown 48-track connector B, track C2 Track 1 EGR valve connector
Injection computer brown 48-track connector B, track D2 Track 5 EGR valve connector
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check that there are no leaks on the EGR circuit (pipes pierced or damaged) and that the clamps are properly
tightened.
Measure the resistance of the EGR valve motor between tracks 1 and 5.
If the resistance displayed is not between 1
Ω < X < 400Ω at 20˚C, replace the EGR valve.
If the valve is jammed or irrevocably seized, replace the EGR valve.
Run command SC036 Reset programming and select EGR valve to reset the EGR valve offsets (see
Replacement of components).
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF272
Page 119 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-119V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51DIESEL INJECTION
Fault finding – Interpretation of faults
DF276
PRESENT
INJECTOR CODE PROGRAMMING
1.DEF : Internal electronic fault when writing
2.DEF : No code in memory
NOTESCondition for applying fault finding ONLY to a present fault:
The fault is declared present after:
–reprogramming the injection computer,
–replacing and programming the injection computer.
Special notes:
If the fault is present:
–the engine speed is limited,
–the level 1 warning light is lit.
1.DEF
NOTESNone.
Program the injector codes using command SC002 Enter injector codes.
Carry out the procedure described in the Interpretation of commands section.
If the fault is still present after switching off the ignition, waiting for 1 minute and then re-establish dialogue,
Follow the interpretation of command SC002 Entering injector codes.
If the fault is still present, contact the Techline.
Otherwise clear the fault memory using RZ007 Fault memory.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF276P
Page 120 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -120V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF276
CONTINUED
2.DEF
NOTESThis fault appears on any blank computer (new or recently
reprogrammed).
WARNING
A computer without the IMA option can be replaced by a computer with this option. The codes are not
saved during command SC003 Save computer data.
In this case, status ET104 Use of Injector Codes becomes YES, fault DF276 Injector Code Programming
will be present, and the engine will operate in defect mode.
Program the injector codes using command SC002 Enter injector codes.
Carry out the procedure described in the Interpretation of commands section.
If the fault is still present after switching off the ignition, waiting 1 minute and then re-establish dialogue:
Follow the interpretation of command SC002 Entering injector codes.
If the fault is still present, contact the Techline.
Otherwise clear the fault memory using RZ007 Fault memory.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
Page 121 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -121V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF532
PRESENT
OR
STOREDALTERNATOR CHARGE SIGNAL
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Above maximum threshold
2.DEF : Below minimum threshold
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on or with the engine
running.
Special notes:
If the fault is present, the level 1 warning light comes on.
IMPORTANT
The fault can appear after the alternator has been saturated for too long.
For stored faults, clear the fault, switch off the ignition and wait for 1 minute before
carrying out a road test to confirm the fault before any operation.
Run a multiplex network test (see 88B, Multiplexing).
If the fault is still present, check the insulation and continuity on the following connection:
Injection computer, connector C, track A3Alternator, Track 2, black connector
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF532
Page 122 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -122V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF619
PRESENT
OR
STOREDEGR VALVE JAMMED OPEN
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after a road test.
Priorities when dealing with a number of faults:
–DF118 EGR solenoid valve servo-control,
–DF209 EGR valve position sensor circuit,
–DF272 EGR valve control circuit,
if they are present or stored.
Special note:
If the fault is present:
–The EGR and turbocharging functions are inhibited.
–The level 1 warning light is lit.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
IMPORTANT
If the EGR valve needs to be replaced to resolve the fault, use command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF619
Page 124 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -124V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF620
PRESENT
OR
STOREDEGR VALVE FOULED
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after a road test.
Priorities when dealing with a number of faults:
–DF118 EGR solenoid valve servo-control,
–DF209 EGR valve position sensor circuit,
–DF272 EGR valve control circuit,
if they are present or stored.
Special note:
If the fault is present:
–the EGR function is inhibited,
–turbocharging is inhibited,
–the level 1 warning light is lit.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
IMPORTANT
If the EGR valve needs to be replaced to resolve the fault, use command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF620
Page 126 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -126V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF621
PRESENT
OR
STOREDEGR VALVE JAMMED OPEN (OBD FAULT)
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after a road test.
Priorities when dealing with a number of faults:
–DF118 EGR solenoid valve servo-control,
–DF209 EGR valve position sensor circuit,
–DF272 EGR valve control circuit,
if they are present or stored.
Special note:
If the fault is present:
–there is heavy smoke coming from the exhaust,
–the OBD warning light will come on after three consecutive driving cycles (starting
+ 5 seconds + switching off the ignition and waiting 1 minute).
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
IMPORTANT
If the EGR valve needs to be replaced to resolve the fault, use command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF621