relay RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals EDC16C36 User Guide
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2011, Model line: SCENIC, Model: RENAULT SCENIC 2011 J95 / 3.GPages: 431, PDF Size: 2.03 MB
Page 76 of 431

13B-76V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF033
PRESENT
OR
STOREDTHERMOPLUNGER 2 RELAY CONTROL CIRCUIT
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on,
– with the engine running,
– actuator command AC064 Thermoplunger no. 2 relay.
Special notes:
Use bornier Elé. 1681 for all operations on the connectors of the engine management
computer.
Use the Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
CC.1
NOTESNone.
1.DEFSpecial note:
This fault appears when the computer control section has
overheated.
Check the conformity of fuses F2 (70A) and F3 (70A) on component 777, replace if necessary.
Check the connections on the additional heater interface unit.
check the engine management computer connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check for + 12 V after ignition feed on connections BP27 and BP35 of component 1550.
If there is no + 12 V, refer to the interpretation of fault DF151 Main relay circuit.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EDC16C36_V48_DF033/EDC16C36_V58_DF033
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
Page 77 of 431

13B-77V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF033
CONTINUED
Check the supply to thermoplungers 2 and 3:
– Disconnect the connector of component 1072.
– Connect a test light between connection 3JC of component 1072 and a chassis earth.
– Run command AC064 Thermoplunger no. 2 relay.
– Disconnect the connector of component 1073.
– Connect a test light between connection 3JD of component 1073 and a chassis earth.
– Run command AC064 Thermoplunger no. 2 relay.
If the test light comes on correctly, measure the resistance of thermoplunger 2 and 3 between the following
connections:
–3JC of component 1072 and a chassis earth,
–3JD of component 1073 and a chassis earth.
If the resistance is greater than 2 Ω, replace thermoplunger 2 or 3.
If the test light does not come on, check the continuity and insulation of the following connections:
– Connection code 3JC between components 1550 and 1072.
– Connection code 3JD between components 1550 and 1073.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the earthing on the additional heater interface unit:
– Disconnect the connector of component 1550.
– Connect a test light between connections 3JAA and BP27 of component 1550.
– Run command AC064 Thermoplunger no. 2 relay.
If the test light comes on correctly, replace the additional heater interface unit.
If the test light does not come on, check the continuity and insulation from + 12 V of the following connection:
– Connection code 3JAA between components 120 and 1550.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
Page 78 of 431

13B-78V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF034
PRESENT
OR
STOREDTHERMOPLUNGER 3 RELAY CONTROL CIRCUIT
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on,
– with the engine running,
– actuator command AC031 Thermoplunger no. 3 relay.
Special notes:
Use bornier Elé. 1681 for all operations on the connectors of the engine management
computer.
Use the Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
CC.1
NOTESNone.
1.DEFSpecial note:
This fault appears when the computer control section has
overheated.
Check the conformity of fuses F2 (70A) and F3 (70A) on component 777, replace if necessary.
Check the connections on the additional heater interface unit.
check the engine management computer connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check for + 12 V after ignition feed on connections BP27 and BP35 of component 1550.
If there is no + 12 V, refer to the interpretation of fault DF151 Main relay circuit.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EDC16C36_V48_DF034/EDC16C36_V58_DF034EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
Page 79 of 431

13B-79V9 MR-372-J84-13B450$102.mif
13B
DF034
CONTINUED
Check the supply to thermoplunger 4:
– Disconnect the connector of component 1074.
– Connect a test light between connection 3JAC of component 1074 and a chassis earth.
– Run command AC031 Thermoplunger relay no.3.
If the test light illuminates correctly, measure the resistance of the thermoplunger 4 between the following
connection:
–3JAC of component 1074 and a chassis earth,
If the resistance is greater than 2Ω, replace thermoplunger 4.
If the test light does not come on, check the continuity and insulation of the following connection:
– Connection code 3JAC between components 1550 and 1074.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the earthing on the additional heater interface unit:
– Disconnect the connector of component 1550.
– Connect a test light between connections 3JAB and BP27 of component 1550.
– Run command AC031 Thermoplunger relay no.3.
If the test light comes on correctly, replace the additional heater interface unit.
If the test light does not come on, check the continuity and insulation from + 12 V of the following connection:
– Connection code 3JAB between components 120 and 1550.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
DIESEL INJECTION
Fault finding – Interpretation of faults
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
Page 84 of 431

13B-84V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF047
PRESENT
OR
STOREDCOMPUTER SUPPLY VOLTAGE
1.DEF: Voltage outside permitted range of values
NOTESConditions for applying the fault finding procedure to a stored fault:
– The fault is declared after the ignition has been switched on
Special notes:
– impossible to start the engine.
Use bornier Elé.1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
1.DEF
NOTESImpossible to start.
Check the continuity and absence of interference resistance on the following connection:
– Connection code AP29 between components 597 and 120.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check the condition of the injection control unit supply relay (R08) in the engine fuse and relay box (no bad
contacts or oxidation on the relay mounting clips).
If there is a repair procedure (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
If the fault does not recur, start the engine and wait 1 min.
Carry out a road test and check the system faults.
If there are no faults, fault finding is complete.
If the fault is still present, contact the Techline.
EDC16C36_V44_DF047/EDC16C36_V4C_DF047/EDC16C36_V48_DF047/EDC16C36_V50_DF047/EDC16C36_V54_DF047/
EDC16C36_V58_DF047
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 89 of 431

13B-89V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF054
CONTINUED 1
CONOTESNone.
Check the condition of the turbocharging solenoid valve (see Wiring Diagram Technical Note, Mégane II ph2,
Scénic II ph2, component code 1475).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the turbocharging solenoid valve between the following connections:
– Connection code 3FB of component 1475.
– Connection code 3MG of component 1475.
If the resistance measured is greater than 1 kΩ or less than 6 Ω, replace the turbocharging solenoid valve.
Check the continuity of the following connections:
– Connection code 3MG between components 1475 and 120.
Check for the presence of + 12 V after relay on the turbocharging solenoid valve connector.
– Connection code 3FB of component 1475.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the turbocharging solenoid valve.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 91 of 431

13B-91V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF054
CONTINUED 3
CC.0NOTESNone.
Check the condition of the turbocharging solenoid valve (see Wiring Diagram Technical Note, Mégane II ph2,
Scénic II ph2, component code 1475).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector(s) is/are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the turbocharging solenoid valve between the following connections:
– Connection code 3FB of component 1475.
– Connection code 3MG of component 1475.
If the resistance measured is greater than 1 kΩ or less than 6 Ω, replace the turbocharging solenoid valve.
Check the continuity and insulation from earth of the following connections:
– Connection code 3MG between components 1475 and 120.
Check for the presence of + 12 V after relay on the turbocharging solenoid valve connector.
– Connection code 3FB of component 1475.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the turbocharging solenoid valve.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 92 of 431

13B-92V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF054
CONTINUED 4
1.DEFNOTESSpecial note:
This fault appears when the computer control section
has overheated.
Check the condition of the turbocharging solenoid valve (see Wiring Diagram Technical Note, Mégane II ph2,
Scénic II ph2, component code 1475).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the turbocharging solenoid valve between the following connections:
– Connection code 3FB of component 1475.
– Connection code 3MG of component 1475.
If the resistance measured is not 15.4 ± 0.1 Ω at 20°C, replace the turbocharging solenoid valve.
Check the continuity and insulation of the following connection:
– Connection code 3MG between components 1475 and 120.
Check for + 12 V after relay feed on the turbocharging solenoid valve connector.
– Connection code 3FB of component 1475.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
– If the fault is stored, clear the fault using AC004 Turbocharging solenoid valve.
– If, when AC004 Turbocharging solenoid valve is running, DF054 ''Turbocharging solenoid valve control
circuit'' 1.DEF is present or stored, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 110 of 431

13B-110V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF086
PRESENT
OR
STOREDCOOLANT PUMP RELAY CONTROL CIRCUITCC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
CO: Open circuit
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the ignition has been switched off and after waiting
for 1 minute,
Or after an actuator control AC195 Electric coolant pump.
Special notes:
The control relay is located in the engine connection unit.
If the fault is present:
– turbocharger reliability compromised,
– coolant reliability compromised,
–the level 1 warning light is lit.
Use bornier Elé. 1681 or Elé. 1590 for any operation on the
injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF086/EDC16C36_V4C_DF086/EDC16C36_V48_DF086/EDC16C36_V50_DF086/EDC16C36_V54_DF086/
EDC16C36_V58_DF086
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 111 of 431

1 3 B - 111V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF086
CONTINUED
CO.0NOTESNone.
Check the condition of the electric coolant pump relay connector (A 20A) (see Wiring Diagram Technical Note
for Mégane II ph2, Scénic II ph2, component code 573) and check that it operates correctly.
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation, continuity and the absence of interference resistance on the following connections:
– connection codes 32A and 32B between components 688 and 1337,
– connection codes 47Q and 115A between components 688 and 120.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for connection code M earth on the turbocharger bearing coolant pump component code 369.
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58