sensor RENAULT SCENIC 2012 J95 / 3.G Engine And Peripherals EDC16CP33 Manual PDF
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2012, Model line: SCENIC, Model: RENAULT SCENIC 2012 J95 / 3.GPages: 510, PDF Size: 2.98 MB
Page 213 of 510

13B-213
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF364
PRESENT
OR
STORED
CONTINUED
If the wiring of the particle filter downstream temperature sensor, component code 1288, is present (with or without
the sensor being present), check the electrical insulation in relation to + 12 V between the following connections:
–3XU between components 120 and 1288,
–3TG between components 120 and 1288.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the refrigerant pressure sensor.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 218 of 510

13B-218
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF569
PRESENT
OR
STOREDTURBOCHARGING CIRCUIT
1.DEF: Turbocharging pressure too high
2.DEF: Turbocharging pressure too low
3DEF: Inconsistency
NOTESPriorities when dealing with a number of faults:
– DF054 Turbocharging solenoid valve control circuit
– DF004 Turbocharging pressure sensor circuit.
Conditions for applying the fault finding procedure to a stored fault:
If the fault is declared present after:
– the ignition is switched on,
– starting for 2.DEF,
– a road test,
– in turbo regulation phase for 1.DEF,
– engine speed > 3000 rpm for 1.DEF,
– system flow > 20 mg/st for 1.DEF.
Special notes:
Use bornier Elé.1681 for any operations on the injection computer connectors.
If the fault is present:
– particle filter regenerations are inhibited (for Vdiag 18, 1C, 54, 20, 58, 5C, 24 only),
– engine torque limited,
– turbocharging regulation is inhibited,
– the EGR function is inhibited,
–the level 1 and EOBD (European On Board Diagnostic) warning lights are lit.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
EDC16CP33_V18_DF569 / EDC16CP33_V1C_DF569 / EDC16CP33_V54_DF569 / EDC16CP33_V20_DF569 / EDC16CP33_V58_DF569 /
EDC16CP33_V5C_DF569 / EDC16CP33_V24_DF569 / EDC16CP33_V04_DF569 / EDC16CP33_V08_DF569 / EDC16CP33_V44_DF569 /
EDC16CP33_V4C_DF569 / EDC16CP33_V34_DF569 / EDC16CP33_V38_DF569 / EDC16CP33_V74_DF569 / EDC16CP33_V28_DF569 /
EDC16CP33_V62_DF569 / EDC16CP33_V26_DF569 / EDC16CP33_V60_DF569
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 219 of 510

13B-219
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF569
CONTINUED 1
1.DEF
2.DEF
3.DEF
NOTESNone.
If the specification of this fault is: 2.DEF: Turbocharging pressure too low, apply test 6: Fuel circuit return
valve check.
Continue fault finding, regardless of whether or not the fuel return rail has been replaced.
For the other specifications, move on to the next step.
If the loss of power was not noted during slight acceleration and if there was a loss of engine power during each
acceleration at full load, replace the diesel fuel injector return rail and its overpressure valve (see MR364
(Mégane II ph2), MR370 (Scénic II ph2), MR 395 (Laguna II ph2), 402 (Vel Satis ph2), 405 (Espace IV ph2)
Mechanical, 13B, Diesel fuel injector return rail: Removal - Refitting).
Check the condition of the turbocharging pressure sensor connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1071).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 220 of 510

13B-220
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF569
CONTINUED 2
Check for continuity and absence of interference resistance of the following connections:
●3LQ between components 120 and 1071,
●3LP between components 120 and 1071,
●3LN between components 120 and 1071.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Test the high pressure fuel circuit:
Apply scenario SC035 High pressure fuel circuit fault finding.
To interpret the result, apply the interpretation of command SC035 (see Interpretation of commands).
With the engine stopped and ignition on, view parameters PR035 Atmospheric pressure and PR041
Turbocharging pressure.
If there is a difference of > 100 mbar, check that the atmospheric pressure reading is consistent (by comparison
with another vehicle for example).
If atmospheric pressure is consistent, replace the turbocharging sensor.
If not, contact the Techline.
Use the Monitool application: MT001 Turbocharging function to check the entire air line (only for Vdiag 04 and
44).
Apply Test 4 Turbocharged air inlet circuit check.
Run Test 7 Variable geometry turbocharger control.
Run Test 8 Turbocharger rotating part.
If the fault is still present, refer to the interpretation of parameter PR041 Turbocharging pressure.
If the fault is still present, contact the Techline.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 221 of 510

13B-221
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF645
PRESENT
OR
STOREDDAMPER VALVE POSITION REGULATION
1.DEF: Data inconsistency
2.DEF: Value outside permitted tolerance values
3.DEF: Damper valve jammed open
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– with the engine running,
– the battery voltage X > 8V.
Priorities when dealing with a number of faults:
– DF038 Computer,
– DF323 Damper valve,
– DF012 Sensor supply voltage no. 2,
– DF646 Damper valve position sensor.
Special notes:
If the fault is present:
–the level 1 warning light is lit (for Vdiag 20, 58, 24, 5C, 26, 28, 60 and 62),
– particle filter regeneration is inhibited.
Use bornier Elé. 1681 for all operations on the engine management computer
connector.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
Check the condition and connection of the damper valve connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1461).
Check the condition and connection of the engine management computer connector (see Wiring Diagram
Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code
120).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33_V18_DF645 / EDC16CP33_V1C_DF645 / EDC16CP33_V54_DF645 / EDC16CP33_V20_DF645 / EDC16CP33_V58_DF645 /
EDC16CP33_V5C_DF645 / EDC16CP33_V24_DF645 / EDC16CP33_V04_DF645 / EDC16CP33_V08_DF645 / EDC16CP33_V44_DF645 /
EDC16CP33_V4C_DF645 / EDC16CP33_V34_DF645 / EDC16CP33_V38_DF645 / EDC16CP33_V74_DF645 / EDC16CP33_V28_DF645 /
EDC16CP33_V62_DF645 / EDC16CP33_V26_DF645 / EDC16CP33_V60_DF645
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 223 of 510

13B-223
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF646
PRESENT
OR
STOREDDAMPER VALVE POSITION SENSORCC.0: Short circuit to earth
CO.0: Open circuit or short circuit to earth
CO.1: Open circuit or short circuit to +12 V
1.DEF: Open circuit or short circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the engine is started,
– a road test.
Priorities when dealing with a number of faults:
– DF012 Sensor supply voltage no. 2.
Special notes:
If the fault is present:
–the level 1 warning light is lit (for Vdiag 20, 58, 24, 5C, 26, 28, 60 and 62),
– particle filter regeneration is inhibited.
Use bornier Elé. 1681 for all operations on the engine management computer
connector.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
CO.1
1.DEF
NOTESNone.
Check the condition of the damper valve connector (see Wiring Diagram Technical Note, Laguna II ph2, Vel
Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 1461).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Laguna II ph2, Vel Satis ph2, Espace IV ph2, Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33_V18_DF646 / EDC16CP33_V1C_DF646 / EDC16CP33_V54_DF646 / EDC16CP33_V20_DF646 / EDC16CP33_V58_DF646 /
EDC16CP33_V5C_DF646 / EDC16CP33_V24_DF646 / EDC16CP33_V04_DF646 / EDC16CP33_V08_DF646 / EDC16CP33_V44_DF646 /
EDC16CP33_V4C_DF646 / EDC16CP33_V34_DF646 / EDC16CP33_V38_DF646 / EDC16CP33_V74_DF646 / EDC16CP33_V28_DF646 /
EDC16CP33_V62_DF646 / EDC16CP33_V26_DF646 / EDC16CP33_V60_DF646
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 226 of 510

13B-226
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF647
PRESENT
OR
STOREDEGR VALVE POSITION REGULATION1.DEF: EGR 1 offset inconsistency
2.DEF: EGR 2 offset inconsistency
3.DEF: Valve jammed closed
4.DEF: Valve jammed open
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on.
– the engine is started,
– a road test,
– if the air flowmeter temperature > 5°C.
Priorities when dealing with a number of faults:
– DF209 EGR valve position sensor circuit,
– DF046 Battery voltage,
– DF012 Sensor supply voltage no. 2,
– DF272 EGR valve control circuit.
Special notes:
–the level 1 and EOBD (European On Board Diagnostic) warning lights are lit for
1.DEF, 2.DEF, and 4.DEF
– only the EOBD (European On Board Diagnostic) warning light is lit for 3.DEF,
– the EGR function is inhibited by the engine management computer,
– reduced performance for 2.DEF and 3.DEF or 1.DEF and 2.DEF (for Vdiags 5C, 58
and 24, and 20, 26, 28, 60, 62).
Use bornier Elé. 1681 for all operations on the engine management computer
connector.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
EDC16CP33_V18_DF647 / EDC16CP33_V1C_DF647 / EDC16CP33_V54_DF647 / EDC16CP33_V20_DF647 / EDC16CP33_V58_DF647 /
EDC16CP33_V5C_DF647 / EDC16CP33_V24_DF647 / EDC16CP33_V04_DF647 / EDC16CP33_V08_DF647 / EDC16CP33_V44_DF647 /
EDC16CP33_V4C_DF647 / EDC16CP33_V34_DF647 / EDC16CP33_V38_DF647 / EDC16CP33_V74_DF647 / EDC16CP33_V28_DF647 /
EDC16CP33_V62_DF647 / EDC16CP33_V26_DF647 / EDC16CP33_V60_DF647
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
Page 229 of 510

13B-229
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF651
PRESENT
OR
STOREDTURBINE UPSTREAM PRESSURE SENSOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistency
NOTESConditions for applying the fault finding procedure to a stored fault:
If the fault is declared present after:
– With the ignition on,
– when the engine is running.
Special notes:
If the fault is present:
– engine torque limited,
– the EGR function is inhibited by the engine management computer,
– the vehicle performance is reduced,
– particle filter regeneration is inhibited,
–the level 1 warning light is illuminated,
–the EOBD (European On Board Diagnostic) warning light is lit (for Vdiag 5C, 58,
24 and 20 (only for M9R761, M9R722, M9R760 and M9R724)).
Priorities when dealing with a number of faults:
DF011 Sensor supply voltage no. 1.
CO.0
NOTESNone.
Check the condition of the turbine upstream pressure sensor connector (component code 1299).
Check the condition of the engine management computer connector (component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33_V18_DF651 / EDC16CP33_V1C_DF651 / EDC16CP33_V54_DF651 / EDC16CP33_V20_DF651 / EDC16CP33_V58_DF651 /
EDC16CP33_V5C_DF651 / EDC16CP33_V24_DF651 / EDC16CP33_V28_DF651 / EDC16CP33_V62_DF651 / EDC16CP33_V26_DF651 /
EDC16CP33_V60_DF651
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62
Page 230 of 510

13B-230
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF651
CONTINUED 1
Check the continuity and insulation from earth of the following connections:
•3MX between components 120 and 1299,
•3MY between components 120 and 1299,
•3MZ between components 120 and 1299.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the wiring of the particle filter downstream temperature sensor, component code 1288, is present (with or without
the sensor being present), check the electrical insulation in relation to + 12 V between the following connections:
–3XU between components 120 and 1288,
–3TG between components 120 and 1288.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the faults DF569 Turbocharging circuit and/or DF1188 Air taken into the turbocharging circuit are present,
perform Test 8 Turbocharger rotating part.
If the fault is still present, replace the turbine upstream pressure sensor.
CC.1
NOTESNone.
Check the condition of the turbine upstream pressure sensor connector (component code 1299).
Check the condition of the engine management computer connector (component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62
Page 231 of 510

13B-231
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check with the diagnostic tool.
V12 MR-372-J84-13B300$074.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF651
CONTINUED 2
Check the continuity and insulation from + 12 V of the following connections:
•3MX between components 120 and 1299,
•3MY between components 120 and 1299,
•3MZ between components 120 and 1299.
If the connection or connections are faulty and if there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the faults DF569 Turbocharging circuit and/or DF1188 Air taken into the turbocharging circuit are present,
perform Test 8 Turbocharger rotating part.
If the fault is still present, replace the turbine upstream pressure sensor.
1.DEF
NOTESNone.
Check the condition of the turbine upstream pressure sensor connector (component code 1299).
Check the condition of the engine management computer connector (component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity and absence of interference resistance on the following connection:
•3MY between components 120 and 1299.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the faults DF569 Turbocharging circuit and/or DF1188 Air taken into the turbocharging circuit are present,
perform Test 8 Turbocharger rotating part.
Replace the turbine upstream pressure sensor if necessary.
If the fault is still present, contact the Techline.
EDC16CP33
Program No.: C4
Vdiag No.: 18, 1C, 20, 24,
26, 28, 54, 58, 5C, 60, 62