engine SSANGYONG KORANDO 2012 Service Manual

SSANGYONG KORANDO 2012 Service Manual KORANDO 2012 SSANGYONG SSANGYONG https://www.carmanualsonline.info/img/67/57504/w960_57504-0.png SSANGYONG KORANDO 2012 Service Manual

Page 429 of 1082

SSANGYONG KORANDO 2012  Service Manual 08-6
1) Coolant Level Check
Park the vehicle on level ground and apply the parking brake. Stop the engine and wait until it is 
cooled down. The coolant level should be between the MAX and MIN mark on

Page 431 of 1082

SSANGYONG KORANDO 2012  Service Manual 08-8
3. CAUTIONS
If 100% of anti-freeze is added, the water pump vane can be damaged and thermal conductivity can 
be decreased resulting in poor circulation in the cooling system which leads to overh

Page 435 of 1082

SSANGYONG KORANDO 2012  Service Manual 08-12
Water pump
The water pump is driven by the engine drive belt and supplies 
the coolant to each area of the engine.
Coolant reservoir
Thermostat
When the engine coolant 
reaches 90℃, the thermo

Page 436 of 1082

SSANGYONG KORANDO 2012  Service Manual 08-132112-01
Coolant temperature 
sensor
Measures the coolant 
temperature and sends the result 
to the engine ECU.
Radiator
Radiates the heat through fins and cools 
down the hot coolant as the coola

Page 442 of 1082

SSANGYONG KORANDO 2012  Service Manual 09-6
Item How to check DTC set value / Action
Output current
B terminal current
Rotor coil 
resistance
L terminal voltage
3. INSPECTION
1) Alternator
Output Test ▶ 
Disconnect the cable connected to

Page 443 of 1082

SSANGYONG KORANDO 2012  Service Manual 09-71452-01
Troubleshooting ▶ 
Item Cause Action
Overcharged batteryDefective alternator voltage regulator Replace
Defective voltage detection wiring Repair or replace
Discharged batteryLoose altern

Page 446 of 1082

SSANGYONG KORANDO 2012  Service Manual 09-10
Jump start ▶
If the battery is weak or terminated, the battery from another vehicle can be used with jumper cables to 
start the engine.
Connecting order ▶
The positive (+) terminal of the d

Page 448 of 1082

SSANGYONG KORANDO 2012  Service Manual 09-12
Battery
It converts the chemical energy to the 
electrical energy and supplies power to the 
corresponding electric units when starting the 
engine.
1. OVERVIEW
The charge system is designed to

Page 453 of 1082

SSANGYONG KORANDO 2012  Service Manual 11-51462-01
3. TROUBLESHOOTING
Problem Possible Cause Action
Engine will not 
crankLow battery voltage Charge or replace
Loose, corroded or damaged battery cable
Repair or replace
Faulty starter or op

Page 454 of 1082

SSANGYONG KORANDO 2012  Service Manual 11-6
Start motor assembly
1. OVERVIEW
The starter (start motor) starts the engine with rotational power by converting the electric energy to the 
mechanical energy.
When the engine is cranking, the pi