ACURA RL KA9 1996 Service Repair Manual

ACURA RL KA9 1996 Service Repair Manual RL KA9 1996 ACURA ACURA https://www.carmanualsonline.info/img/32/56992/w960_56992-0.png ACURA RL KA9 1996 Service Repair Manual
Trending: ECO mode, open hood, four wheel drive, fuse chart, oil filter, steering wheel, ESP

Page 581 of 1954

ACURA RL KA9 1996  Service Repair Manual PGM-FI Syste m
Throttle Positio n (TP ) Senso r (cont'd )
The sca n too l indicate s Diagnosti c Troubl e Cod e (DTC ) P0123 : A  hig h voltag e proble m in  th e Throttl e Positio n
(TP) senso r

Page 582 of 1954

ACURA RL KA9 1996  Service Repair Manual 
The scan tool indicates Diagnostic Trouble Code (DTC) P1121: Throttle Position (TP) lower than expected.

— The MIL has been reported on.

— DTC P1121 is stored.

Problem verification:

1. Turn t

Page 583 of 1954

ACURA RL KA9 1996  Service Repair Manual PGM-FI Syste m
Primar y Heate d Oxyge n Senso r (HO2S ) (Senso r 1 )
Th e Heate d Oxyge n Sensor s (HO2S ) detec t th e oxyge n conten t i n th e exhaus t ga s an d signa l th e PCM . I n operation ,

Page 584 of 1954

ACURA RL KA9 1996  Service Repair Manual (From pag e 11-84 )
Chec k fo r a  shor t i n  th e HO2S :
1 . Tur n th e ignitio n switc h OFF .
2. Disconnec t th e righ t primar yHO2S (Ban k 1 , Senso r 1 ) o r
lef t primar y HO2S * (Ban k 2 ,
Se

Page 585 of 1954

ACURA RL KA9 1996  Service Repair Manual PGM-FI Syste m
Primar y Heate d Oxyge n Senso r (HO2S ) (Senso r 1 ) (cont'd )
The sca n too l indicate s Diagnosti c Troubl e Cod e (DTC ) P0132 : A  hig h voltag e proble m in th e Righ t Primar

Page 586 of 1954

ACURA RL KA9 1996  Service Repair Manual The sca n too l indicate s Diagnosti c Troubl e Cod e (DTC ) P0133 : A  slo w respons e proble m in th e Righ t Primar y
Heate d Oxyge n Senso r (Righ t Primar y HO2S ) (Ban k 1 , Senso r 1 ) circuit

Page 587 of 1954

ACURA RL KA9 1996  Service Repair Manual PGM-FI Syste m
Secondar y Heate d Oxyge n Senso r (HO2S ) (Senso r 2 )
Th e sca n too l indicate s Diagnosti c Troubl e Cod e (DTC ) P0137 : A  lo w voltag e proble m in th e Secondar y Heate d
Oxygen

Page 588 of 1954

ACURA RL KA9 1996  Service Repair Manual The sca n too l indicate s Diagnosti c Troubl e Cod e (DTC ) P0138 : A  hig h voltag e proble m in  th e Secondar y Heate d
Oxygen Senso r (HO2S ) (Senso r 2 ) circuit .
— Th e MI L ha s bee n repor

Page 589 of 1954

ACURA RL KA9 1996  Service Repair Manual 
PGM-FI System

Secondary Heated Oxygen Sensor (HO2S) (Sensor 2) (cont'd)

Does the voltage stay within

0.3 - 0.6 V for 2 minutes? 
NO 
Intermittent failure, system is OK

at this time. Check for

Page 590 of 1954

ACURA RL KA9 1996  Service Repair Manual Heated Oxyge n Senso r (HO2S ) Heate r
The sca n too l indicate s Diagnosti c Troubl e Cod e (DTC ) P0135 : A  proble m in th e Righ t Primar y Heate d Oxyge n
Sensor (Righ t Primar y HO2S ) (Ban k 1
Trending: headlight bulb, wheel bolt torque, boot, gearbox, window, oil level, change time