battery ASTON MARTIN DB7 1997 Manual PDF
Page 413 of 421
The Aston Martin Lagonda Diagnostic System 
Users Guide ^2? 
Split Cursor Icon 
The split cursor icon spl its the vertical cursor into 
two parts. 
1^ 
VV 
One permanent static cursor represented by
 a
 solid vertical 
line in the waveform display, and one moveable cursor 
represented by a dotted vertical line, this is moved by 
applying finger pressure to the screen in the position the 
cursor is required. 
The digital display of the waveforms will now represent 
the difference in levels between the two cursors and not 
the absolute signal level as detailed earlier. 
Re-scale Vertical Icon 
Normally all of the waveforms are displayed 
with the vertical axis representing the maximum 
possible variation ofthesignal,
 e.g.
 battery voltage 
0 to 16 V. 
The re-scale icon causes the waveform to scale such that 
the recorded variation determines the scale, this normally 
enlarges the vertical scale. 
The scaling operation can be performed on any of the 
displayed waveforms by highlighting the parameter name 
prior to the operation. 
Once auto-scaling
 has
 taken place, further manual scaling 
may be achieved by using the '+' and '-' system icons. 
Waveform Display Number 
This icon enables control of the number of 
waveforms displayed on the screen at any one 
MMV 
MMV 
time. 
Pressing this icon causes the '+' and '-' system icons to 
appear. Using these system icons increase or decrease the 
number of displayed waveforms. 
It should be noted that the more waveforms displayed the 
poorer the detail becomes, therefore the number of 
displayed waveforms should be kept to a minimum. 
Horizontal Scale 
-^ This icon performs the same function as the re-
scale vertical icon only for the horizontal axis. 
By expanding the scale more detail will be available, thus 
proving easier to analyse. However the amount of time 
displayed on any one screen will be reduced. 
Bargraph / Digital display 
Bargraph / Digital display provides another format in 
which to display recorded date. 
The Datalogger icons operate similar to those used in the 
waveform display. However one new icon is provided as 
a toggle option from bargraph to digital display. 
OV 
TP :3.91V 
ECT: 57°C 5V 
-49°C lAT: 0°C 150°C 
-49°C 150°C 
II 88 zF 1^ 
Bargraph / Digital Display 
On-Road Trigger 
When on-road trigger is selected using the motorway icon 
from the main menu a symbol is displayed over the entire 
screen display area. 
This option is intended for use during on-road tests to 
ensure that the PDU screen does not distract the driver. 
Press the record icon to start capturing data, a trigger icon 
will replace the record
 icon. 
• iF • 
Datalogger Trigger Icon 
Press the trigger icon to instigate the manual trigger. 
Once the trigger procedure has occurred, a stop icon will 
replace the trigger
 icon.
 Press the stop icon to stop 
capturing data. 
9-62 September 1996