INFINITI FX35 2007 Service Manual

Page 3811 of 4366

ELECTRICAL UNITS LOCATION PG-67
C
D E
F
G H
I
J
L
M A
B
PG
Revision: 2006 July 2007 FX35/FX45
ELECTRICAL UNITS LOCATIONPFP:25230
Electrical Units Location NKS003GP
ENGINE COMPARTMENT
CKIM0646E

Page 3812 of 4366

PG-68
ELECTRICAL UNITS LOCATION
Revision: 2006 July 2007 FX35/FX45
PASSENGER COMPARTMENT
CKIM0647E

Page 3813 of 4366

ELECTRICAL UNITS LOCATION PG-69
C
D E
F
G H
I
J
L
M A
B
PG
Revision: 2006 July 2007 FX35/FX45
CKIM0648E

Page 3814 of 4366

PG-70
ELECTRICAL UNITS LOCATION
Revision: 2006 July 2007 FX35/FX45
LUGGAGE COMPARTMENT
CKIM0649E

Page 3815 of 4366

HARNESS CONNECTOR PG-71
C
D E
F
G H
I
J
L
M A
B
PG
Revision: 2006 July 2007 FX35/FX45
HARNESS CONNECTOR PFP:00011
DescriptionNKS003GQ
HARNESS CONNECTOR (TAB-LOCKING TYPE)
The tab-locking type connectors help prevent accidental looseness or disconnection.
The tab-locking type connectors are disconnected by pushing or lifting the locking tab(s). Refer to the fig-
ure below.
Refer to the next page for description of the slide-locking type connector.
CAUTION:
Never pull the harness or wires when disconnecting the connector.
[Example]
SEL769DA

Page 3816 of 4366

PG-72
HARNESS CONNECTOR
Revision: 2006 July 2007 FX35/FX45
HARNESS CONNECTOR (SLIDE-LOCKING TYPE)
A new style slide-locking type connector is used on certain systems and components, especially those
related to OBD.
The slide-locking type connectors help prevent incomplete locking and accidental looseness or discon-
nection.
The slide-locking type connectors are disconnected by pushing or pulling the slider. Refer to the figure
below.
CAUTION:
Never pull the harness or wires when disconnecting the connector.
Be careful not to damage the connector support bracket when disconnecting the connector.
[Example]
SEL769V

Page 3817 of 4366

HARNESS CONNECTOR PG-73
C
D E
F
G H
I
J
L
M A
B
PG
Revision: 2006 July 2007 FX35/FX45
HARNESS CONNECTOR (LEVER LOCKING TYPE)
Lever locking type harness connectors are used on certain control units and control modules such as
ECM, ABS actuator and electric unit (control unit), etc.
Lever locking type harness connectors are also used on super multiple junction (SMJ) connectors.
Always confirm the lever is fully locked in place by moving the lever as far as it will go to ensure full con-
nection.
CAUTION:
Always confirm the lever is fully released (loosened) before attempting to disconnect or connect these
connectors to avoid damage to the connector housing or terminals.
LKIA0670E
1. Control unit with single lever
A. Fasten
B. Loosen
C. Lever 2. Control unit with dual levers
A. Levers
B. Fasten
C. Loosen 3. SMJ connector
A. Lever
B. Fasten
C. Loosen

Page 3818 of 4366

PG-74
ELECTRICAL UNITS
Revision: 2006 July 2007 FX35/FX45
ELECTRICAL UNITS PFP:00011
Terminal Arrangement NKS003GR
CKIM0650E

Page 3819 of 4366

ELECTRICAL UNITS PG-75
C
D E
F
G H
I
J
L
M A
B
PG
Revision: 2006 July 2007 FX35/FX45
CKIM0218E

Page 3820 of 4366

PG-76
SMJ (SUPER MULTIPLE JUNCTION)
Revision: 2006 July 2007 FX35/FX45
SMJ (SUPER MULTIPLE JUNCTION)PFP:B4341
Terminal ArrangementNKS003GS
CKIM0651E