POWER DOOR LOCK SYSTEM
Revision: October 20052005 QX56
4. CHECK POWER WINDOW BUS CIRCUIT FOR SHORT
Check continuity between BCM connector M18 terminal 22 and
ground.
OK or NG
OK >> Replace main power window and door lock/unlock switch or power window and door lock/unlock
switch RH
NG >> Repair or replace harness.
Glass Hatch Switch Circuit InspectionEIS008PQ
1. CHECK GLASS HATCH SWITCH
1. Turn ignition switch OFF.
2. Insure front door lock actuator RH is in the unlock position.
3. Check continuity between glass hatch switch terminal 2 and ground.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. CHECK HARNESS CONTINUITY
1. Disconnect glass hatch switch.
2. Disconnect BCM.
3. Check continuity between BCM connector M18 (A) terminal 30
and glass hatch switch connector D710 (B) terminal 2.
4. Check continuity between BCM connector M18 (A) terminal 30
and ground.
OK or NG
OK >> Glass hatch switch circuit is OK.
NG >> Repair or replace harness.22 - Ground : Continuity should not exist.
LIIA2359E
Connec-
torTe r m i n a l s
Condition Continuity
(+) (–)
D710 2 GroundWith the glass hatch switch
pressedYe s
With the glass hatch switch
releasedNo
LIIA2399E
30 - 2 : Continuity should exist.
30 - Ground : Continuity should not exist.
LIIA2400E
Page 804 of 3419
POWER DOOR LOCK SYSTEM
BL-37
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
3. CHECK GLASS HATCH SWITCH
1. Disconnect glass hatch switch.
2. Check continuity between glass hatch switch terminal 1 and
ground.
OK or NG
OK >> Replace glass hatch switch.
NG >> GO TO 4.
4. CHECK HARNESS CONTINUITY
1. Disconnect front door lock actuator RH.
2. Check continuity between glass hatch switch connector D710
(A) terminal 1 and front door lock actuator RH connector D114
(B) terminal 4
OK or NG
OK >> GO TO 5.
NG >> Repair or replace harness.
5. CHECK FRONT DOOR LOCK ACTUATOR RH
Check continuity between front door lock actuator RH connector
D114 terminal 5 and ground
OK or NG
OK >> Replace front door lock actuator RH.
NG >> Repair or replace harness.1 - Ground : Continuity should exist.
LIIA2401E
1 - 4 : Continuity should exist.
LIIA2402E
5 - Ground : Continuity should exist.
LIIA2403E
Page 805 of 3419
BL-38
POWER DOOR LOCK SYSTEM
Revision: October 20052005 QX56
Front Door Lock Assembly LH (Actuator) CheckEIS008PR
1. CHECK DOOR LOCK ACTUATOR SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between BCM connector M20 terminals 59, 65
and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace BCM. Refer to BCS-20, "
Removal and Installation of BCM" .
2. CHECK DOOR LOCK ACTUATOR HARNESS
1. Disconnect BCM and front door lock assembly LH (actuator).
2. Check continuity between BCM connector M20 terminals 59, 65
and front door lock assembly LH (actuator) connector D14 termi-
nals 2, 3.
3. Check continuity between BCM connector M20 terminals 59, 65
and ground.
OK or NG
OK >> Replace front door lock assembly LH (actuator). Refer to BL-131, "FRONT DOOR LOCK" .
NG >> Repair or replace harness.
ConnectorTerminals
ConditionVoltage (V)
(Approx.)
(+) (-)
M2059
GroundDriver door lock/unlock
switch is turned to
UNLOCK0 → Battery voltage
65Driver door lock/unlock
switch is turned to LOCK0 → Battery voltage
LIIA1046E
Connector Terminals Connector Terminals Continuity
M2059
D142Yes
65 3 Yes
Connector Terminals Continuity
M2059
GroundNo
65 No
LIIA1574E
Page 806 of 3419
POWER DOOR LOCK SYSTEM
BL-39
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Front Door Lock Actuator RH CheckEIS008PS
1. CHECK FRONT DOOR LOCK ACTUATOR RH SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between BCM connector M20 terminals 65, 66
and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace BCM. Refer to BCS-20, "
Removal and Installation of BCM" .
2. CHECK FRONT DOOR LOCK ACTUATOR RH HARNESS
1. Disconnect BCM and front door lock actuator RH.
2. Check continuity between BCM connector M20 terminals 65, 66
and front door lock actuator RH D114 terminals 2, 3.
3. Check continuity between BCM connector M20 terminals 65, 66
and ground.
OK or NG
OK >> Replace front door lock actuator RH. Refer to BL-131, "FRONT DOOR LOCK" .
NG >> Repair or replace harness.
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
M2065
GroundDoor lock/unlock switch is
turned to LOCK0 → Battery voltage
for 300 ms
66Door lock/unlock switch is
turned to UNLOCK0 → Battery voltage
for 300 ms
LIIA1048E
Terminals Continuity
65 3 Yes
66 2 Yes
Terminals Continuity
65
GroundNo
66 No
LIIA1479E
Page 807 of 3419
BL-40
POWER DOOR LOCK SYSTEM
Revision: October 20052005 QX56
Rear Door Lock Actuator RH/LH CheckEIS008PT
1. CHECK DOOR LOCK ACTUATOR SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between BCM connector M20 terminals 65, 66
and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace BCM. Refer to BCS-20, "
Removal and Installation of BCM" .
2. CHECK REAR DOOR LOCK ACTUATOR LH OR RH HARNESS
1. Disconnect BCM and each door lock actuator.
2. Check continuity between BCM connector M20 terminals 65, 66
and rear door lock actuator RH/LH connectors terminals 2, 3.
3. Check continuity between BCM connector M20 terminals 65, 66
and ground.
OK or NG
OK >> Replace door lock actuator. Refer to BL-134, "REAR DOOR LOCK" .
NG >> Repair or replace harness.
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
M2065
GroundDoor lock/unlock switch
is turned to LOCK0 → Battery voltage
for 300 ms
66Door lock/unlock switch
is turned to UNLOCK0 → Battery voltage
for 300 ms
LIIA1048E
Terminals Continuity
65 3 Yes
66 2 Yes
Terminals Continuity
65
GroundNo
66 No
LIIA1480E
Page 808 of 3419
POWER DOOR LOCK SYSTEM
BL-41
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Glass Hatch Lock Actuator CheckEIS008PU
1. CHECK GLASS HATCH LOCK ACTUATOR SIGNAL
1. Turn ignition switch OFF.
2. Check voltage between BCM connector M19 terminal 53 and
ground.
OK or NG
OK >> GO TO 2.
NG >> Replace BCM. Refer to BCS-20, "
Removal and Installa-
tion of BCM" .
2. CHECK GLASS HATCH LOCK ACTUATOR HARNESS
1. Disconnect BCM and glass hatch lock actuator.
2. Check continuity between BCM connector M19 terminal 53 and
glass hatch lock actuator connector D711 terminal 3.
3. Check continuity between BCM connector M19 terminals 53 and
ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK GLASS HATCH LOCK ACTUATOR GROUND CIRCUIT
1. Disconnect glass hatch lock actuator.
2. Check continuity between glass hatch lock actuator connector
D711 terminal 1 and ground.
OK or NG
OK >> Replace glass hatch lock actuator. Refer to BL-135,
"BACK DOOR LOCK" .
NG >> Repair or replace harness.
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
M19 53 GroundGlass hatch switch is
turned to depressed0 → Battery voltage
for 300 ms
LIIA1938E
Terminals Continuity
53 3 Yes
Terminals Continuity
53 Ground No
LIIA1939E
Terminals Continuity
1Ground Yes
LIIA1940E
Page 809 of 3419
BL-42
POWER DOOR LOCK SYSTEM
Revision: October 20052005 QX56
Front Door Lock Assembly LH (Key Cylinder Switch) CheckEIS008PV
1. CHECK DOOR KEY CYLINDER SWITCH LH
With CONSULT-II
Check front door lock assembly LH (key cylinder switch) ("KEY CYL LK-SW") and ("KEY CYL UN-SW) in
DATA MONITOR mode with CONSULT–II. Refer to BL-27, "
DATA MONITOR" .
When key inserted in front key cylinder is turned to LOCK:
When key inserted in front key cylinder is turned to UNLOCK:
Without CONSULT-II
Check voltage between main power window and door lock/unlock
switch connector D7 terminals 4, 6 and ground.
OK or NG
OK >> Front door lock assembly LH (key cylinder switch) signal is OK.
NG >> GO TO 2.
2. CHECK DOOR KEY CYLINDER SWITCH LH GROUND HARNESS
Check continuity between front door lock assembly LH (key cylinder
switch) connector (A) D14 terminal 5 and body ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.KEY CYL LK-SW : ON
KEY CYL UN-SW : ON
LIIA0188E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
D74
GroundNeutral/Unlock 5
Lock 0
6Neutral/Lock 5
Unlock 0
LIIA0566E
Connector Terminals Continuity
D14 5 – Ground Yes
WIIA0755E
Page 810 of 3419
POWER DOOR LOCK SYSTEM
BL-43
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
3. CHECK DOOR KEY CYLINDER SWITCH LH
Check continuity between front door lock assembly LH (key cylinder
switch) terminals.
OK or NG
OK >> GO TO 4.
NG >> Replace front door lock assembly LH (key cylinder switch). Refer to BL-131, "
FRONT DOOR
LOCK" .
4. CHECK DOOR KEY CYLINDER HARNESS
Check continuity between main power window and door lock/unlock
switch connector (A) D7 terminals 4, 6 and front door lock assembly
LH (key cylinder switch) connector (B) D14 terminals 1, 6 and body
ground.
OK or NG
OK >> Replace main power window and door lock/unlock switch.
NG >> Repair or replace harness.
Terminals Condition Continuity
1 – 5 Key is turned to UNLOCK or neutral. No
Key is turned to LOCK. Yes
5 – 6Key is turned to LOCK or neutral. No
Key is turned to UNLOCK. Yes
LIIA1573E
Connector Terminals ConnectorTe r m i n a l s
(wire color)Continuity
A: Main
power win-
dow and
door lock/
unlock
switch4 B: Front
door lock
assembly
LH (key
cylinder
switch)1Yes
66Yes
4, 6 Ground No
WIIA0756E
Page 812 of 3419
REMOTE KEYLESS ENTRY SYSTEM
BL-45
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
System DescriptionEIS008PX
INPUTS
Power is supplied at all times
to BCM terminal 70
through 50A fusible link (letter f , located in the fuse and fusible link box).
to BCM terminal 57
through 15A fuse [No. 22, located in the fuse block (J/B)].
When the key is inserted in the key switch and key lock solenoid, power is supplied
to BCM terminal 37
through key switch and key lock solenoid terminals 3 and 4
through 10A fuse [No. 19, located in the fuse block (J/B)].
When the ignition switch is ACC or ON, power is supplied
to BCM terminal 11
through 10A fuse [No. 4, located in the fuse block (J/B)].
When the ignition switch is ON or START, power is supplied
to BCM terminal 38
through 10A fuse (No. 59, located in the fuse and relay box).
When the front door switch LH is ON (door is OPEN), ground is supplied
to BCM terminal 47
through front door switch LH terminal 2
through front door switch LH case ground.
When the front door switch RH is ON (door is OPEN), ground is supplied
to BCM terminal 12
through front door switch RH terminal 2
through front door switch RH case ground.
When the rear door switch LH is ON (door is OPEN), ground is supplied
to BCM terminal 48
through rear door switch LH terminal 2
through rear door switch LH case ground.
When the rear door switch RH is ON (door is OPEN), ground is supplied
to BCM terminal 13
through rear door switch RH terminal 2
through rear door switch RH case ground.
When the back door latch (door ajar switch) is ON (door is OPEN), ground is supplied
to BCM terminal 43
through back door latch (door ajar switch) terminal 7,
through back door latch (door ajar switch) terminal 8,
through body grounds B7 and B19.
Keyfob signal is input into the BCM from the remote keyless entry receiver.
The remote keyless entry system controls operation of the
power door lock
back door opener
interior lamp and step lamps
panic alarm
hazard and horn reminder
keyless power window down (open)
auto door lock operation
Page 813 of 3419
BL-46
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
OPERATING PROCEDURE
When the keyfob is operated, the signal from the keyfob is sent and the remote keyless entry receiver
receives the signal and sends it to the BCM. The BCM only locks/unlocks the doors if the ID number
matches. (Remote control entry functions)
Using the keyfob, the transmitter sends radio waves to the remote keyless entry receiver, which then
sends the received waves to the BCM. Only if the ID number matches does the BCM lock/unlock the
doors. (Remote control door function)
Unless the key is inserted into the ignition key cylinder or one of the doors is opened within 1 minute after
the UNLOCK switch on the keyfob is pressed, all the doors are automatically locked. (Auto lock function)
When a door is locked or unlocked, the vehicle turn signal lamps flash and the horn sounds to verify oper-
ation. (Active check function)
When the key is in the ignition key cylinder (when the key switch is ON) and one of the doors is open, the
door lock function does not work even when the door lock is operated with the keyfob.
Keyfob ID set up is available.
If a keyfob is lost, a new keyfob can be set up. A maximum of 5 IDs can be set up simultaneously.
Remote Control Entry Functions
Operation Description
When a button on the keyfob is operated, the signal is sent from the keyfob and received by the remote
keyless entry receiver.
The received signal is sent to the BCM and compared with the registered ID number.
If the ID number matches, the BCM sends the lock/unlock signal to each door lock actuator.
When the door lock actuators receive this signal, each operates to lock/unlock its door.
BCM locks all doors with input of LOCK signal from keyfob.
When an UNLOCK signal is sent from keyfob once, driver's door will be unlocked.
Then, if an UNLOCK signal is sent from keyfob again within 5 seconds, all other doors will be unlocked.
Remote control entry operation conditions
Auto Lock Function
Operation Description
Unless the key is inserted into the ignition key cylinder, one of the doors is opened, or the keyfob is oper-
ated within 1 minute after a door lock is unlocked by keyfob operation, all the doors are automatically
locked.
The 1 minute timer count is executed by the BCM and after 1 minute, the BCM sends the lock signal to all
doors.
Lock operations are the same as for the remote control entry function.
Remote Control Automatic Back Door Function
Switching from all closed to all open
When a button on the keyfob is operated, the signal is sent from the keyfob and received by the remote
keyless entry receiver.
The received signal is sent to the BCM and compared with the registered ID number.
If the ID number matches, the BCM uses power window serial link communication to send the back door
open signal to the back door control unit
When the back door control unit receives the back door open signal for 0.5 seconds, if the remote control
automatic back door operation enable conditions are met, the warning chime is sounded and the back
door unlock signal is sent to the back door latch using communication.
When the back door latch receives the back door unlock signal, it operates the release actuator and
releases to back door latch.
Keyfob operation Operation condition
Door lock operation (locking)
With key removed (key switch: OFF)
Closing all doors (door switch: OFF)
Door lock operation (unlocking) With key removed (key switch: OFF)