lock INFINITI QX56 2006 Factory Service Manual

Page 827 of 3383

BL-46
REMOTE KEYLESS ENTRY SYSTEM
Revision: November 20092006 QX56
OPERATING PROCEDURE
When the keyfob is operated, the signal from the keyfob is sent and the remote keyless entry receiver
receives the signal and sends it to the BCM. The BCM only locks/unlocks the doors if the ID number
matches. (Remote control entry functions)
Using the keyfob, the transmitter sends radio waves to the remote keyless entry receiver, which then
sends the received waves to the BCM. Only if the ID number matches does the BCM lock/unlock the
doors. (Remote control door function)
Unless the key is inserted into the ignition key cylinder or one of the doors is opened within 1 minute after
the UNLOCK switch on the keyfob is pressed, all the doors are automatically locked. (Auto lock function)
When a door is locked or unlocked, the vehicle turn signal lamps flash and the horn sounds to verify oper-
ation. (Active check function)
When the key is in the ignition key cylinder (when the key switch is ON) and one of the doors is open, the
door lock function does not work even when the door lock is operated with the keyfob.
Keyfob ID set up is available.
If a keyfob is lost, a new keyfob can be set up. A maximum of 5 IDs can be set up simultaneously.
Remote Control Entry Functions
Operation Description
When a button on the keyfob is operated, the signal is sent from the keyfob and received by the remote
keyless entry receiver.
The received signal is sent to the BCM and compared with the registered ID number.
If the ID number matches, the BCM sends the lock/unlock signal to each door lock actuator.
When the door lock actuators receive this signal, each operates to lock/unlock its door.
BCM locks all doors with input of LOCK signal from keyfob.
When an UNLOCK signal is sent from keyfob once, driver's door will be unlocked.
Then, if an UNLOCK signal is sent from keyfob again within 5 seconds, all other doors will be unlocked.
Remote control entry operation conditions
Auto Lock Function
Operation Description
Unless the key is inserted into the ignition key cylinder, one of the doors is opened, or the keyfob is oper-
ated within 1 minute after a door lock is unlocked by keyfob operation, all the doors are automatically
locked.
The 1 minute timer count is executed by the BCM and after 1 minute, the BCM sends the lock signal to all
doors.
Lock operations are the same as for the remote control entry function.
Remote Control Automatic Back Door Function
Switching from all closed to all open
When a button on the keyfob is operated, the signal is sent from the keyfob and received by the remote
keyless entry receiver.
The received signal is sent to the BCM and compared with the registered ID number.
If the ID number matches, the BCM uses power window serial link communication to send the back door
open signal to the back door control unit
When the back door control unit receives the back door open signal for 0.5 seconds, if the remote control
automatic back door operation enable conditions are met, the warning chime is sounded and the back
door unlock signal is sent to the back door latch using communication.
When the back door latch receives the back door unlock signal, it operates the release actuator and
releases to back door latch.
Keyfob operation Operation condition
Door lock operation (locking)
With key removed (key switch: OFF)
Closing all doors (door switch: OFF)
Door lock operation (unlocking) With key removed (key switch: OFF)

Page 828 of 3383

REMOTE KEYLESS ENTRY SYSTEMBL-47
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
The back door control unit operates the back door motor to open the back door. (At this time, speed con-
trol, input reverse, and overload reverse control are executed.)
When the back door is opened to the fully open position, the full-open position is detected with the rotation
sensor, the back door motor is stopped.
The door held by the back door stays at the full open position.
Full open → full closed operation
When a button of the keyfob is operated, the signal is sent from the keyfob and received by the remote
keyless entry receiver.
The received signal is sent to the BCM and compared with the registered ID number.
If the ID number matches, the BCM uses power window serial link communication to send the back door
close request signal to the back door control unit.
When the back door control unit receives the back door close request signal for 0.5 seconds, if the remote
control automatic back door operation enable conditions are met, the warning chime is sounded and the
back door motor begins closing the back door.
The back door control unit operates the magnetic clutch and the back door motor to close the back door.
(At this time, the back door control unit executes speed control, input reverse, and overload reverse con-
trol.)
When the back door comes to the half-latch state, the back door latch detects the half-latch state through
half-latch switch operation. The back door latch latches the back door.
For the automatic back door system operation enable conditions, refer to BL-99, "
AUTOMATIC BACK DOOR
SYSTEM" .
Active Check Function
Operation Description
When a door is locked or unlocked by keyfob operation, the vehicle turn signals flash and the horn sounds to
verify operation.
When a button on the keyfob is operated, the signal is sent from the remote controller and received by the
keyless remote entry receiver.
The received signal is sent to the BCM and compared with the registered ID number.
If the ID number matches, the BCM sends the turn signal flashing and horn signal to the IPDM E/R.
The IPDM E/R flashes the turn signal lamps and sounds the horn for each keyfob operation.
Operating function of hazard and horn reminder
Hazard and Horn Reminder
BCM output to IPDM E/R for horn reminder signal as DATA LINE (CAN-H and CAN-L).
The hazard and horn reminder has C mode (horn chirp mode) and S mode (non-horn chirp mode).
How to change hazard and horn reminder mode With CONSULT-II
Hazard and horn reminder can be changed using “WORK SUPPORT” mode in “MULTI ANSWER BACK SET".
Without CONSULT-II
Refer to Owner's Manual for instructions.
Interior Lamp Operation
When the following input signals are both supplied:
all door switches are in the OFF position. (when all the doors are closed);
interior lamp switch is in DOOR position.
Remote keyless entry system turns on interior lamp and ignition keyhole illumination (for 30 seconds) with
input of UNLOCK signal from keyfob.
For detailed description, refer to LT- 1 3 6 , "
ROOM LAMP TIMER OPERATION" .
C mode S mode
Keyfob operation LockUnlock LockUnlock
Hazard warning lamp
flash Twice
OnceTwice —
Horn sound Once———

Page 829 of 3383

BL-48
REMOTE KEYLESS ENTRY SYSTEM
Revision: November 20092006 QX56
Panic Alarm Operation
When key switch is OFF (when ignition key is not inserted in key cylinder), remote keyless entry system turns
on and off horn and headlamp intermittently with input of PANIC ALARM signal from keyfob.
The alarm automatically turns off after 25 seconds or when BCM receives any signal from keyfob.
Keyless Power Window Down (Open) Operation
When keyfob unlock switch is turned ON with ignition switch OFF, and the switch is detected to be ON contin-
uously for more than 1 second, the driver's door and passenger's door power windows are simultaneously
opened.
Power window is operated to open and the operation continues as long as the keyfob unlock switch is
pressed.
CAN Communication System DescriptionEIS005ZR
Refer to LAN-26, "CAN COMMUNICATION" .

Page 834 of 3383

REMOTE KEYLESS ENTRY SYSTEMBL-53
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
Terminals and Reference Value for BCMEIS005ZU
Te r m i n a l Wire
Color Item
Condition Voltage (V)
(Approx.)
11 O Ignition switch (ACC or ON) Ignition switch (ACC or ON position) Battery voltage
12 R/L Front door switch RH Door open (ON) → Door close (OFF) Battery voltage → 0
13 GR Rear door switch RH Door open (ON) → Door close (OFF) Battery voltage → 0
18 P Remote keyless entry
receiver ground —
0
19 V/W Remote keyless entry
receiver (Power supply)
Ignition switch OFF
20 G/W Remote keyless entry
receiver signal (Signal) Stand-by (keyfob buttons released)

When remote keyless entry receiver
receives signal from keyfob (keyfob
buttons pressed)
37 B/R Key switch and key lock sole-
noid (insert) Key inserted in IGN key cylinder (ON)

Key removed from IGN key cylinder
(OFF) Battery voltage
→ 0
38 W/L Ignition switch (ON or
START) Ignition switch (ON or START posi-
tion)
Battery voltage
39 L CAN-H ——
40 P CAN-L ——
43 R/B Back door latch (door ajar
switch) Door open (ON) →
Door close (OFF) 0 → Battery voltage
47 SB Front door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
48 R/Y Rear door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
56 R/G Battery saver
(Interior lamp) Battery saver does operated →
Does
not operated (ON → OFF) Battery voltage
→ 0
57 Y/R Battery power supply —Battery voltage
59 G Front door lock assembly LH
(actuator) (unlock) Door lock & unlock switch
(Neutral
→ Unlock) 0
→ Battery voltage
60 G/B Turn signal LH When doors are locked or unlocked
using keyfob (OFF →
ON) *2 0
→ Battery voltage
61 G/Y Turn signal RH When doors are locked or unlocked
using keyfob (OFF →
ON) *2 0
→ Battery voltage
62 R/W Step lamp LH and RH Step lamp ON
0
Step lamp OFF Battery voltage
LIIA1893E
LIIA1894E
LIIA1895E

Page 835 of 3383

BL-54
REMOTE KEYLESS ENTRY SYSTEM
Revision: November 20092006 QX56
*1: when room lamp switch is in "DOOR" position.
*2: when hazard reminder is ON.
Terminals and Reference Value for IPDM E/REIS005ZV
*: when horn reminder is ON.63 L Room lamp
Room lamp ON *1
Battery voltage
Room Lamp OFF *1 0
65 V All door lock actuators (lock) Door lock & unlock switch
(Neutral
→ Lock) 0
→ Battery voltage
66 G/Y Front door lock actuator RH,
rear door lock actuators LH/
RH and back door lock actu-
ator (unlock) Door lock & unlock switch
(Neutral
→ Unlock) 0
→ Battery voltage
67 B Ground —0
69 W/R Rear power window power
supply —
Battery voltage
70 W/B Battery power supply —Battery voltage
Te r m i n a l
Wire
Color Item
Condition Voltage (V)
(Approx.)
Te r m i n a l Wire
Color Item
Condition Voltage (V)
(Approx.)
38 B Ground —0
39 L CAN-H ——
40 P CAN-L ——
45 G/W Horn relay When doors locks are operated
using keyfob (OFF →
ON) * Battery voltage
→ 0
59 B Ground —0

Page 837 of 3383

BL-56
REMOTE KEYLESS ENTRY SYSTEM
Revision: November 20092006 QX56
5. Touch “BCM”.
If "BCM" is not indicated, refer to GI-40, "
CONSULT-II Data Link
Connector (DLC) Circuit" .
6. Touch “MULTI REMOTE ENT ”.
7. Select diagnosis mode. “DATA MONITOR ”, “ACTIVE TEST” and “WORK SUPPORT ”
are available.
CONSULT-II Application ItemsEIS005ZY
“MULTI REMOTE ENT”
Data Monitor
BCIA0030E
LIIA0194E
BCIA0031E
Monitored Item Description
DOOR SW-AS Indicates [ON/OFF] condition of front door switch RH.
DOOR SW-RR Indicates [ON/OFF] condition of rear door switch RH.
DOOR SW-RL Indicates [ON/OFF] condition of rear door switch LH.
DOOR SW-DR Indicates [ON/OFF] condition of front door switch LH.
BACK DOOR SW Indicates [ON/OFF] condition of back door latch.
KEY ON SW Indicates [ON/OFF] condition of key switch.
ACC ON SW Indicates [ON/OFF] condition of ignition switch in ACC position.
IGN ON SW Indicates [ON/OFF] condition of ignition switch in ON position.
KEYLESS PANIC Indicates [ON/OFF] condition of panic signal from keyfob.
KEYLESS UNLOCK Indicates [ON/OFF] condition of unlock signal from keyfob.
KEYLESS LOCK Indicates [ON/OFF] condition of lock signal from keyfob.
KEY CYL LK-SW Indicates [ON/OFF] condition of lock signal from door key cylinder switch.
KEY CYL UN-SW Indicates [ON/OFF] condition of unlock signal from door key cylinder switch.
KEYLESS PBD Indicates [ON/OFF] condition of power back door signal from keyfob.

Page 838 of 3383

REMOTE KEYLESS ENTRY SYSTEMBL-57
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
Active Test
Work Support
CDL UNLOCK SWIndicates [ON/OFF] condition of unlock signal from lock/unlock switch.
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from lock/unlock switch.
DOOR SW-RL Indicates [ON/OFF] condition of rear door switch LH.
DOOR SW-RR Indicates [ON/OFF] condition of rear door switch RH.
RKE LCK-UNLCK Indicates [ON/OFF] condition of lock/unlock signal at the same time from keyfob.
RKE KEEP UNLK Indicates [ON/OFF] condition of unlock signal from keyfob.
TRNK OPN MNTR Indicates [ON/OFF] condition of glass open switch.
Monitored Item
Description
Test ItemDescription
FLASHER This test is able to check right and left hazard reminder operation. The right hazard lamp turns on
when “RH” on CONSULT-II screen is touched and the left hazard lamp turns on when "LH" on CON-
SULT-II screen is touched.
POWER WINDOW DOWN This test is able to check power window down operation. The windows are lowered when “ON ” on
CONSULT-II screen is touched.
HORN This test is able to check panic alarm and horn reminder operations. The alarm activate for 0.5 sec-
onds after “ ON” on CONSULT-II screen is touched.
DOOR LOCK This test is able to check door lock operation. The doors lock and unlock based on the item on CON-
SULT-II screen touched.
TRUNK/BACK DOOR This test is able to check back door actuator operation. The back door is opened when “OPEN ” on
CONSULT-II screen is touched.
PSB/PBD OPEN TEST This test is able to check power back door operation. The power back door is fully opened when

OPEN ” on the CONSULT-II screen is touched if the door operation enable conditions are met.
Test Item Description
REMO CONT ID REGIST Keyfob ID code can be registered.
REMO CONT ID ERASUR Keyfob ID code can be erased.
REMO CONT ID CONFIR It can be checked whether keyfob ID code is registered or not in this mode.
HORN CHIRP SET Horn chirp function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
HAZARD LAMP SET Hazard lamp function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
MULTI ANSWER BACK SET Hazard and horn reminder mode can be changed in this mode. The reminder mode will be changed
when
“CHANG SETT ” on CONSULT-II screen is touched.
AUTO LOCK SET Auto locking function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
PANIC ALRM SET Panic alarm operation mode can be changed in this mode. The operation mode will be changed
when "CHANG SETT" on CONSULT-II screen is touched.
TRUNK OPEN SET Back door opener operation mode can be changed in this mode. The operation mode will be
changed when "CHANG SETT" on CONSULT-II screen is touched.
PW DOWN SET Keyless power window down (open) operation mode can be changed in this mode. The operation
mode will be changed when "CHANG SETT" on CONSULT-II screen is touched.

Page 839 of 3383

BL-58
REMOTE KEYLESS ENTRY SYSTEM
Revision: November 20092006 QX56
Hazard and horn reminder mode
Auto locking function mode
Panic alarm operation mode
Back door open operation mode
Keyless power window down operation mode
MODE 1
(C mode) MODE 2
(S mode) MODE 3 MODE 4 MODE 5 MODE 6
Keyfob
operation Lock Unlock Lock Unlock Lock Unlock Lock Unlock Lock Unlock Lock Unlock
Hazard warning
lamp flash Twice Onc e Twice
———Twice Once Twice ——Once
Horn sound Once ——————— Once—Once —
MODE 1 MODE 2 MODE 3
Auto locking function 5 minutesNothing1 minute
MODE 1 MODE 2 MODE 3
Keyfob operation 0.5 secondsNothing1.5 seconds
MODE 1 MODE 2 MODE 3
Keyfob operation 0.5 secondsNothing0.5 seconds
MODE 1 MODE 2 MODE 3
Keyfob operation 3 secondsNothing5 seconds

Page 840 of 3383

REMOTE KEYLESS ENTRY SYSTEMBL-59
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
Trouble Diagnosis ProcedureEIS005ZZ
1. Check the symptom and customer's requests.
2. Understand outline of system. Refer to BL-45, "
System Description" .
3. Confirm system operation.
Check that the power door lock system operates normally. Refer to BL-16, "POWER DOOR LOCK
SYSTEM" .
Check that the automatic back door system operates normally. Refer to BL-99, "AUTOMATIC BACK
DOOR SYSTEM" .
4. Perform pre-diagnosis inspection. Refer to BL-59, "
BCM Power Supply and Ground Circuit Check" .
5. Refer to trouble diagnosis chart by symptom, repair or replace any malfunctioning parts. Refer to BL-60,
"Trouble Diagnoses" .
6. Inspection End.
BCM Power Supply and Ground Circuit CheckEIS00600
1. CHECK FUSE AND FUSIBLE LINK
Check the following BCM fuses and fusible link.
NOTE:
Refer to BL-44, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of problem before installing new fuse, refer to PG-4,
"POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM.
3. Check voltage between BCM connectors M18, M20 terminals 11, 38, 57, 70 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
Component Parts Terminal No. (SIGNAL) AmpereNo. Location
BCM 57 (BAT power supply)
15A22 Fuse block (J/B)
70 (BAT power supply) 50AfFuse and fusible link box
11 (ACC power supply) 10A4 Fuse block (J/B)
38 (IGN power supply) 10A59 Fuse and relay box
ConnectorTerminals
Signal nameIgnition
switch Vo l ta g e
(+) ( –)
M20 70
Ground Battery power
supply OFFBattery
voltage
57 Battery power
supply OFFBattery
voltage
M18 11
ACC power
supply ACC
Battery
voltage
38 IGN power
supply ONBattery
voltage
WIIA0600E

Page 841 of 3383

BL-60
REMOTE KEYLESS ENTRY SYSTEM
Revision: November 20092006 QX56
3. CHECK GROUND CIRCUIT
Check continuity between BCM connector M20 terminal 67 and
ground.
OK or NG
OK >> Power supply and ground circuit is OK.
NG >> Repair or replace harness.
Trouble DiagnosesEIS00601
SYMPTOM CHART
NOTE:
Always check the "Trouble Diagnosis Procedure" before troubleshooting. Refer to BL-59, "Trouble Diag-
nosis Procedure" .
Always check keyfob battery before replacing keyfob. Refer to BL-65, "Keyfob Battery and Function
Check" .
The panic alarm operation and power back door opener operation of remote keyless entry system do not
activate with the ignition key inserted in the ignition key cylinder.
Use Remote Keyless Entry Tester J-43241 (follow instructions on tester) to check operation of keyfob
before replacing keyfob.
ConnectorTerminals
Continuity
(+) (-)
M20 67Ground Yes
LIIA1040E
Symptom Diagnoses/service procedureReference
page
All functions of remote keyless entry system do not
operate. 1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning. BL-65
2. Check BCM and keyless receiver.
BL-66
The new ID of keyfob cannot be entered.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.
BL-652. Key switch and key lock solenoid (insert) check
BL-62
3. Door switch checkBL-63
4. ACC power checkBL-68
5. Replace BCM.BCS-20
Door lock or unlock does not function.
(If the power door lock system does not operate
manually, check power door lock system. Refer to
BL-16, "
POWER DOOR LOCK SYSTEM" )1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.
BL-65
2. Replace BCM.
BCS-20
Hazard and horn reminder does not activate prop-
erly when pressing lock or unlock button of keyfob.1. Check hazard and horn reminder mode with CONSULT-II
NOTE:
Hazard and horn reminder mode can be changed.
First check the hazard and horn reminder mode setting.
BL-57,
"Active
Te s t"
2. Door switch check
BL-63
3. Replace BCM.BCS-20

Page:   < prev 1-10 ... 101-110 111-120 121-130 131-140 141-150 151-160 161-170 171-180 181-190 ... 510 next >