30.Install the engine cover. (see 'EM' group)
When replacing the automatic transaxle, reset the automatic transaxle's values by using the High- Scan Pro.
a. Connect the Hi - Scan Pro connector to the data link connector under the crash pad and power cable to the cigar
jack under the center facia.
b. Turn the ignition switch on and power on the Hi - Scan Pro.
c. Select the vehicle's name.
d. Select 'AUTOMATIC TRANSAXLE'.
e.Select 'RESETTING AUTO T/A VALUES' and perform the procedure.
f.Perform the procedure by pressing F1 (REST).

Page 392 of 1575

Valve Body System

Page 393 of 1575

Solenoid Valve

Page 394 of 1575

2007 > 2.7L V6 GASOLINE >
DESCRIPTION
Actuators
Solenoid Valve for Pressure Control
- Sensor type: Normal open 3 - way
- Operating temperature : - 30°C~130°C( - 22°F~266°F)
- Frequency:
LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above - 20°C(- 4°F))
DCC: 30.64Hz
- Internal resistance:
3.0 ± 0.5 Ω (LR, 2ND, UD, OD, TCC)
4.35 ± 0.5 Ω (VFS)
- Surge voltage: 56 V (Except VFS)
(LR, 2ND, UD, OD, DCC)
Location
Solenoid Valves Schedule
Position Solenoid valves
Operation LR2ND UDOD* DCC
1st gear OFFONOFF ONOFF
2nd gear ONOFF OFF ONOFF
3rd gear ONONOFF OFF ON
4th gear ONOFF ONOFF ON
Reverse OFFONONONOFF
N, P (STD. mode) OFFONONONOFF
N, P (Hold mode) ONOFF ONONOFF
*: Reference value.
(DCC solenoid valve will be ON when the operating condition is satisfied)

Page 395 of 1575

2007 > 2.7L V6 GASOLINE >
INSPECTION
1.If the value is out of specification according to the chart below, remove the valve body cover.
2.Measure the resistance again after disconnecting solenoid valve connector.
Specification (20°C):
2.5 ~ 3.5 Ω (LR, 2ND, UD, OD, TCC)
3. If the value is out of specification replace the solenoid valve.
Pin No. NameResistance
6&9 DCC (TCC)
2.5~3.5Ω (20°C)
6&11
LR
4&5 2ND
3&5 UD
5&12 OD

Page 396 of 1575

Page 397 of 1575

VFS
( Variable Force Solenoid) Valve

Page 398 of 1575

2007 > 2.7L V6 GASOLINE >
DESCRIPTION
Actuators
Solenoid Valve for Pressure Control
- Sensor type: Normal open 3 - way
- Operating temperature : - 30°C~130°C( - 22°F~266°F)
- Frequency:
LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above - 20°C(- 4°F))
DCC: 30.64Hz
- Internal resistance:
3.0 ± 0.5 Ω (LR, 2ND, UD, OD, TCC)
4.35 ± 0.5 Ω (VFS)
- Surge voltage: 56 V (Except VFS)
(VFS)
Location
VFS Control pressure
Input Current(mA) Control Pressure (No line pressure)
Increasing Current Decreasing Current
MAX. (Kgf/cm²) ¦Kpa§ MIN. (Kgf/cm²)
¦Kpa§ Δ
(Kgf/cm²) ¦Kpa§ MIN. (Kgf/cm²)
¦Kpa§
100 6.52¦639§ 5.87¦575§ ¦64§
200 6.23¦611§ 5.70¦559§ ¦52§5.43¦532§
300 5.76¦564§ 5.24¦514§ ¦50§4.49¦484§
400 5.08¦498§ 4.59¦450§ ¦48§4.30¦421§
500 4.24¦416§ 3.78¦370§ ¦46§3.52¦345§

Page 399 of 1575

7002.29¦224§ 1.82¦178§ ¦46§1.51¦148§
800 1.41¦138§ 0.09¦88§ ¦50§0.58¦57§
900 0.65¦64§ 0.14¦14§ ¦50§0¦0§
1,000 0.24¦24§ 0¦0§¦24§
1,100 0.24¦24§ 0¦0§¦24§
*Test condition:
Ps : Supply Pressure (Ps ¹7.1 ± 0.3 KGf/cm²)
Pc : Control Pressure
Pex : Exhaust Pressure (Atmosphere pressure)
ATF : DIAMOND ATF SP - â…¢
ATF temperature : 30 ± 3°C (86°F)
- Coil resistance : 4.35 ± 35Ω
- Dither Frequency : 600 ± 20Hz
In case of VFS solenoid valve, the relation between Duty and oil pressure can't be expressed.

Page 400 of 1575

2007 > 2.7L V6 GASOLINE >
INSPECTION
1.If the value is out of specification according to the chart below, remove the valve body cover.
2.Measure the resistance again after disconnecting solenoid valve connector.
Specification (20°C):
4.3 ~ 4.4Ω (VFS)
3.If the value is out of specification replace the solenoid valve.
Pin No. NameResistance
7&8 VFS4.3~4.4Ω (20°C)