Charge TOYOTA RAV4 PHEV 2021 Service Manual

Page 147 of 666

145
2
2-2. Charging
Plug-in hybrid system
to the set time.
By adjusting the cabi n temperature in
advance, passengers can enjoy a
pleasant interior immediately after
entering the vehicle.
*: Operation starts approximately 20
minutes before the set departure
time.
■Turning “Charge Now” on and
off
If even one charging schedule is
registered, charging does not start
until the set time, even if the AC
charging cable is connected to the
vehicle. To start c harging without
changing the charging schedule
setting, turn “Charge Now” on to
temporarily cancel the charging
schedule and enable charging after
connecting the AC charging cable.*
*: If the charging connector is removed
during charging while the charging
schedule is registered and “Charge
Now” is on, “Charg e Now” turns off.
■Changing “Next Event”*1
It is possible to temporarily set the
time of the next charging schedule
without changing the registered
repeated setting.*2
*1: The “Next Event” refers to the clos -
est charging sched ule from the cur-
rent time among t he registered
charging schedules. Charging
schedule is performed based on the
“Next Event”.
*2: When “Next Event” is changed, the
current charging schedule will be
temporarily ignored and charging will
not be carried out until the time
specified by “Ne xt Event”. (For
example, when “Nex t Event” is set
for 2 days later, e ven if items are
registered on the charging schedule,
charging will not be carried out until
the time specified by “Next Event”.)
The charging schedule can be reg-
istered on the multi-information dis -
play: →P.147
■Charging schedule
●The charging schedule cannot be set while driving.
●A maximum of 15 charging schedules can be registered.
■To make sure that the charging
schedule function operates cor -
rectly
Check the following items.
●Adjust the clock to the correct time ( →P.179)
●The calendar is set to the correct date
( →P.186)
●Check that the power switch is turned
off
●After registering the charging sched-
ule, connect the AC charging cable The charging start time is determined
based on the charging schedule at the
time that the AC charging cable was
Registering the charging
schedule

Page 148 of 666

1462-2. Charging
connected.
●After connecting the AC charging
cable, check that the charging indica -
tor of the charging port flashes ( →P.106)
●Do not use an socket that has a power cut off function (including a timer func -
tion)
Use an socket that constantly supplies electricity. For sockets where the
power is cut off due to a timer func -
tion, etc., charging may not be carried out according to plan if the power is
cut off during the set time.
■When the AC charging cable
remains connected to the vehicle
Even if multiple consecutive charging
schedules are registered, the next
charge will not be ca rried out according to the charging schedule until the AC
charging cable is removed and recon-
nected after charging completes. Also, when the hybrid battery (traction battery)
is fully charged, charging according to
the charging schedule will not be carried out.
■“Climate Prep”
●When the air condit ioning-linked set- ting is turned on, the air conditioning
operates until the se t departure time.
Therefore, the air conditioning will consume electricity and charging may
not complete by the set departure
time.
●If the hybrid battery (traction battery)
is fully charged, cha rging will not be carried out, even if the charging
schedule is set. However, if “Climate
Prep” is turned on, the air conditioning will operate only once when it nears
the time set in “De parture”. If this
occurs, the air conditioning will con -
sume electricity and the remaining charge of the hybrid battery (traction
battery) when departing may be
decreased.
●When the doors are unlocked, the air
conditioning system does not operate.
■When charging schedules are
ignored
When the following operations are per -
formed while the charging schedule is
on standby, charging schedule is tempo - rarily canceled and charging is started.
●When the Remote Air Conditioning System ( →P.460) is operated
●When turning “My Room Mode” on ( →P.153)
●When turning “Charge Now” on ( →P.150)
●When an operation that temporarily cancel charging using the charging
schedule ( →P.138)
■Effects of outside temperature
When the charging mode is set to “Departure”, chargin g schedule may be
ignored due to the outside temperature
and charging may start.
■“Battery Heater” ( →P.128) /“Battery Cooler” ( →P.129)
When charging is carried out using the
charging schedule, the hybrid battery (traction battery) heating or cooling func -
tion may operate according to the tem -
perature of the hybrid battery (traction battery).
●When the charging mode is set to “Start”, the function starts at the set
charging start time.
●“Battery Heater”: When the charging
mode is set to “Dep arture”, the func-
tion starts automatic ally to complete heating by the desired departure time.
●“Battery Cooler”: When the charging mode is set to “Dep arture”, cooling
starts approximately 30 minutes
before the charging start time. How -
ever, if there is no time to finish charging by the charging schedule,
the hybrid battery (traction battery)
cooling time may be shortened and “Battery Cooler” may not operate.

Page 152 of 666

1502-2. Charging
played.
3 Press or of the meter
control switches to select the
item to operate, press and
perform the necessary opera -
tion.
 “Edit”
Change the desired settings as
described start ing from step 7 of the
“Registering the charging schedule”
procedure. ( →P.147)
Press to return to the previous
screen.
 “Delete”
A deletion confirmation screen will be
displayed.
Press or of the meter control
switches to select “Yes”, and then
press to delete the selected
charging schedule.
To cancel deletion, select “No” and
then press .
Press to return to the previous
screen.
■Setting “Charge Now” to on
The “Charge Now” setting can be
changed by perform ing one of the
two following procedures.
Operation on “Charging Sched -
ule” screen
1 Perform step 1 to 4 of the “Reg-
istering the charging schedule”
procedure ( →P.147) and display
“Charging Schedule” screen.
2 Press or of the meter
control switches to select
“Charge Now”, and then press
.
Each time is pressed, “Charge
Now” switches bet ween on and off.
Operation on “Closing Display”
screen*
*: If “Closing Display” is not set to
“Charging Schedule” on the
screen of the multi-information dis -
play, the “Closing Display” is not dis -
played. In this case, check the

Page 153 of 666

151
2
2-2. Charging
Plug-in hybrid system
settings on the multi-information dis -
play.
1 Turn the power switch off.
The “Closing Display” screen is dis-
played on the multi-information display.
( →P.152)
2Press to set “Charge Now”
to on.
Each time is pressed, “Charge
Now” switches between on and off.
After setting operations are com -
plete, charging starts when the AC
charging cable is connected.
( →P.135)
■Changing “Next Event”*
*: When “Charge Now” is set to on or
when using “My Room Mode”
( →P.153) etc., it is not possible to
change the registered “Next Event”.
1 Perform step 1 to 4 of the “Reg-
istering the charging schedule”
procedure ( →P.147) and display
“Charging Schedule” screen.
2 Press or of the meter
control switches to select “Next
Event”, and then press .
The “Next Event” screen will be dis -
played.
3 Press or of the meter
control switches to select “Yes”,
and then press .
The confirmation message will be dis -
played on the screen.
Press , and the “Charging Mode”
screen will be displayed.
Press to return to the previous
screen.
4 Change the desired settings as
described starting from step 7 o f
the “Registering the charging
schedule” procedure. ( →P.147)
Press to return to the previous
screen.
■When charging schedule setting
operations are canceled
When the vehicle is in the following con - ditions, charging schedule setting oper -
ations are canceled.
●The power switch i s operated before

Page 154 of 666

1522-2. Charging
the settings are confirmed
●The vehicle starts off
●A display with a high er priority than that of the charging schedule setting
is shown
■“Next Event”
After charging completes, the “Next Event” displayed on the multi-informa -
tion display will no t change until the AC
charging cable is removed, even after charging is performed according to the
“Next Event” schedule.
■To return to original setting after
changing “Next Event” setting
Turning the setting of “Charge Now” on
and then off can return the setting of
“Next Event” to its original setting.
■When “Next Event” is changed while charging
●When the charging mode is “Depar - ture”, the current charging is inter -
rupted or continued depending on the
remaining time until the charging is completed.
●When the charging mode is “Start”, the current charging is interrupted, the
next charging will start at the set time.
■When the power switch is turned
off
You can check the next charging sched -
ule (“Next Event”) on the “Closing Dis -
play” screen* when “Closing Display” is
set to “Charging Schedule” on
screen of the multi-in formation display
and the power switc h is turned off.*: The “Closing Display” screen may not
be displayed during charging.
WARNING
■Cautions while performing the
setting operation
When performing the setting opera- tion while the hybrid system is oper -
ated, ensure that the vehicle is parked
in a place with adequate ventilation. In a closed area such as a garage,
exhaust gases including harmful car -
bon monoxide (CO) may collect and
enter the vehicle. This may lead to death or a serious health hazard.
NOTICE
■While performing the setting operation
When performing the setting opera-
tion while the hybrid system is stopped, be careful that the 12-volt
battery will not be discharged.

Page 155 of 666

153
2
2-2. Charging
Plug-in hybrid system
1 Connect the AC charging cable
to the vehicle and start charging
2 Turn the power switch on during
charging
The setting screen of “My Room Mode”
is displayed automat ically on the multi-
information display.
3 Press or of the meter
control switches, select “Yes”,
and then press .
“My Room Mode” starts and systems
such as the air conditioning system and
audio system can be used inside the vehicle.
When not using “My Room Mode”,
select “No”, and then press .
To stop “My Room Mode”, turn the
power switch off.
When “My Room Mode” starts, the
remaining charge display screen for
the hybrid battery (traction battery)
is displayed automatically on the
multi-information display. The
approximate power balance (bal -
ance between electricity supply and
consumption) while using “My
Room Mode” can be checked from
the color and size of the arrows.
Discharging status
Charging status
When the electricity supply from the AC
charging cable is larger than the power
consumption inside the vehicle,
becomes larger. When the power con -
sumption is larger than the electricity
supply, becomes larger.
When the electricity supply and con -
sumption are balanced (when the
power balance is judged to be zero),
and are displayed as the same
size.
Using the “My Room
Mode”
When the AC charging cable is
connected to the vehicle, elec -
trical components such as the
air conditioning system or
audio system can be used
using the external power
source.
Starting “My Room Mode”
Display of power balance
information while using “My
Room Mode”
A
B
B
A
AB

Page 156 of 666

1542-2. Charging
■When a door is unlocked while using “My Room Mode”
The charging connector unlocks,
charging stops and “My Room Mode” stops. In order to use “My Room Mode”
again, reconnect the AC charging cable
and start “My Room Mode” ( →P.153). When using “My Room Mode” with pub -
lic charging station, operation to start
charging using the charger may be required again before starting “My Room
Mode”.
■Meter display during charging
If “My Room Mode” is not turned on for approximately 100 seconds after the
power switch is turned on during
charging, the power switch will automat- ically turn off.
■While using “My Room Mode”
Any of the follo wing may occur.
●When the remaining charge of the
hybrid battery (traction battery)
reaches the lower l imit, the air condi- tioning system automat ically turns off.
In this situation, the air conditioning
system cannot be us ed until the remaining charge of the hybrid battery
(traction battery) increases. Turn the
power switch off and use “My Room Mode” after the remaining charge of
the hybrid battery ( traction battery) is
restored.
●When the outside te mperature is low,
the heater o utput may be limited due
to the air conditioning system opera - tion being restricted.
●Warning lights and indicators such as electric power steering system warn -
ing light (yellow) and malfunction indi -
cator lamp may turn on, but this is not a malfunction.
Also, when the surrounding area is
dark, the headlight s are turned on. ( →P.332)
■When a charging schedule is regis-
tered
When “My Room Mode” starts while the charging schedule is on standby,
charging schedules are ignored and
charging starts.
■When “My Room Mode” is used while the hybrid battery (traction
battery) is fully charged
When the power switch is turned on while the hybrid battery (traction battery)
is fully charged and the charging con -
nector that supplies power is connected, “Charging Port Lid i s Open” is displayed
on the multi-informati on display. In this
case, press of th e meter control
switches to display the setting screen of “My Room Mode”, and then select “My
Room Mode”.
When “My Room Mode ” is used while the hybrid battery ( traction battery) is
fully charged, the ele ctric power of the
hybrid battery (trac tion battery) may be consumed. In this case, charging may
be performed again.
■When a message related to “My
Room Mode” is displayed
When a message is displayed on the
multi-information display while using or
attempting to start “My Room Mode”, take the following correction proce -
dures.
●“Traction battery is too low for “My
Room Mode””
There is insufficient remaining charge in
the hybrid battery ( traction battery) for
starting “My Room Mode”.
Wait until the charge of the hybrid bat-
tery (traction batter y) increases, then
start “My Room Mode”.
●““My Room Mode” has stopped due to
low traction battery”
The remaining charge in the hybrid bat -
tery (traction battery) is insufficient.
Stop using “My Room Mode” and
charge the hybrid battery (traction bat -
tery).
●““My Room Mode” will stop when trac -
tion battery is too low Reduce power
usage to continue using “My Room

Page 157 of 666

155
2
2-2. Charging
Plug-in hybrid system
Mode””
The power consumptio n inside the vehi-
cle is greater tha n the power being
charged to the hybrid battery (traction
battery), and the remaining charge of
the hybrid battery (traction battery) is
low.*
• “My Room Mode” will end unless the power consumption inside the vehicle
is improved.
• To continue using “My Room Mode”, turn off the power of systems such as
the air conditioni ng system and audio
system to increase the remaining charge of the hybrid battery (traction
battery).*: The power balance status during “My
Room Mode” can be checked from the
remaining charge display screen for
the hybrid battery (traction battery)
displayed on the multi-information dis -
play.
WARNING
■Cautions for using “My Room
Mode”
Make sure to observe the following
precautions.
Failure to do so may result in serious health problems or even death.
●Do not leave chil dren, people who need assistance, or pets inside the
vehicle. The sys tem may turn off
automatically and the interior tem- perature may become high or low,
resulting in heat stroke, dehydration
or hypothermia. Devices such as the wipers can also be used, which
may lead to mistaken operation and
an accident.
●Check the safety around the vehicle
carefully before use.

Page 158 of 666

1562-2. Charging
Refer to the following table and carry out the appropriate correction proce-
dure.
■The power source indicator on the CCID (Charging Circuit Interr upt-
ing Device) does not illuminate , even though the plug is connected
to an external power source.
When charging cannot be carried out
When charging does not start, even though the normal procedure is
followed, check each of the following items.
If a message is shown on the multi-information display, also refer to
P.160.
When charging cannot be carried out
Likely causeCorrection procedure
Plug is not properly c onnected to socketCheck that the plug is properly con-
nected to the socket.
Power is outAfter power is resto red, carry out the
charging procedure again.
Remote switch is offIf the remote switch is equipped, turn the
switch on.
Building breaker is tripped and power is
cut off
Check that the breaker is connected and
if there is no malfunc tion, check if the
vehicle can be charged through another
socket.
If charging is possible, the first socket
may have a malfunct ion. Contact the
building or facility manager, or an electri -
cian.
Short circuit betwe en CCID (Charging
Circuit Interrupting Device) and plug
Immediately stop c harging and contact
any authorized Toyota retailer or Toyota
authorized repairer, or any reliable
repairer.

Page 159 of 666

157
2
2-2. Charging
Plug-in hybrid system
■The error warning indicator on the CCID (Charging Circuit Inter rupt-
ing Device) flashes.
■Charging indicator of the charging port does not illuminate, ev en
though charging connector is connected.
Likely causeCorrection procedure
Electrical leakage det ection function or
self-diagnostic function operates and
power is cut off
When the voltage is insufficient, the error
warning indicator may flash when there
is noise interference. Perform a reset
and connect to a pro per power source.
( →P.113)
If charging does not s tart, immediately
stop charging and contact any authorized
Toyota retailer or Toyota authorized
repairer, or any reliable repairer.
Likely causeCorrection procedure
The plug is not properly connected to the
socket
Check whether the plug is properly con -
nected to the socket.
Charging connector is not securely con -
nected to AC charging inlet
Check the connection status of the
charging connector.
• When connecting the charging con-
nector, insert the charging connector
securely.
• After connecting the charging connec-
tor, check that the charging indicator of
the charging port is turned on.
If the charging indica tor of the charging
port does not illuminate, even though the
charging connector is securely con -
nected, there may be a malfunction in the
system. Immediately st op charging and
contact any authorized Toyota retailer or
Toyota authorized r epairer, or any reli-
able repairer.
Hybrid battery (traction battery) is
already fully charged
When the hybrid battery (traction battery)
is fully charged, charging is not per -
formed.
The charger does not operatePlease contact the facility manager when
there is a probl em with charger.

Page:   < prev 1-10 ... 11-20 21-30 31-40 41-50 51-60 61-70 71-80 81-90 ... 130 next >