ESP DATSUN PICK-UP 1977 Workshop Manual
[x] Cancel search | Manufacturer: DATSUN, Model Year: 1977, Model line: PICK-UP, Model: DATSUN PICK-UP 1977Pages: 537, PDF Size: 35.48 MB
Page 501 of 537

DISCHARGING
SYSTEM
The
pressurized
refrigerant
gas
Ul
side
system
must
be
discharged
to
a
pressure
approaching
atmospheric
pressure
prior
to
evacuating
refrigerant
inside
system
This
operation
should
be
made
to
permit
safe
re
oval
when
replacing
system
components
I
Close
high
and
low
pressure
valves
of
manifold
gauge
fully
2
Connect
two
charging
hoses
of
manifold
gauge
to
their
respective
service
valves
3
Open
both
manifold
gauge
valves
slightly
and
slowly
discharge
refriger
ant
from
system
See
Figure
AC
17
Note
Do
not
allow
refrigerant
to
rush
out
Otherwise
compressor
oil
will
be
discharged
along
with
re
frigerant
AC735
Fig
AC
17
Discharging
system
Caution
Protect
fingers
with
cloth
against
frostbite
by
refrigerant
when
connecting
the
charging
hose
to
the
service
valve
or
disconnecting
it
therefrom
Air
Conditioning
EVACUATING
SYSTEM
1
Connect
high
and
low
pressure
charging
hoses
of
manifold
gauge
to
their
respective
service
valves
of
sys
tern
and
d
ischarge
refrigerant
from
system
Refer
to
Discharge
System
2
When
refrigerant
has
been
dis
charged
to
a
pressure
approaching
at
mospheric
pressure
connect
center
charging
hose
to
a
vacuum
pump
3
Close
both
valves
of
manifold
gauge
fully
Then
start
vacuum
pump
4
Open
low
pressure
valve
and
suck
old
refrigerant
from
ystem
See
Figure
AC
18
S
When
low
pressure
gauge
reading
has
reached
to
approximately
500
mm
Hg
20
in
Hg
slowly
open
high
pressure
valve
See
Figure
AC
19
6
When
pressure
inside
system
has
dropped
to
710
mm
Hg
28
in
Hg
fully
close
both
of
valves
of
manifold
gauge
and
stop
vacuum
pump
Let
stand
it
for
5
to
10
minutes
in
this
state
and
confirm
that
the
reading
does
not
rise
Notes
a
The
low
pressure
gauge
reads
lower
by
2S
mm
Hg
I
in
Hg
per
a
300
m
1
000
ft
elevation
Perform
evacu
ation
according
to
the
following
table
Elevation
m
ft
Vacuum
of
system
mm
Hg
in
Hg
0
0
300
I
000
600
2
000
900
3
000
710
28
68S
27
660
26
635
25
Note
Values
show
readings
of
the
low
pressure
gauge
AC
12
b
The
rate
of
ascension
of
the
low
pressure
gauge
should
be
less
than
2S
mm
Hg
I
in
Hg
in
five
min
utes
If
the
pressure
rises
or
the
specified
negative
pressure
can
not
be
obtained
there
is
a
leak
in
the
system
In
this
case
immediately
charge
system
with
refrigerant
and
repair
the
leak
de
scribed
in
the
following
I
Confirm
that
both
valves
of
manifold
gauge
are
fully
closed
and
then
disconnect
center
charging
hose
from
vacuum
pump
2
Connect
center
hose
to
can
tap
in
place
of
vacuum
pump
Attach
refrigerant
can
to
can
tap
and
pass
refrigerant
to
manifold
gauge
3
Loosen
the
connection
of
center
fitting
of
manifold
gauge
to
purge
air
from
center
hose
4
Open
low
pressure
valve
of
mani
fold
gauge
and
charge
refrigerant
into
system
After
one
can
about
0
4
kg
I
Ib
of
refrigerant
has
been
charged
into
system
close
low
pressure
valve
5
Check
for
refrigerant
leakage
with
a
leak
detector
Repair
any
leak
ages
found
Refer
to
Checking
for
Leaks
and
Refrigerant
Leaks
6
Confirm
that
both
valves
of
manifold
gauge
are
fully
closed
and
then
change
center
charging
hose
from
can
tap
to
vacuum
pump
7
Open
high
and
low
pressure
valves
and
operate
vacuum
pump
to
suck
refrigerant
from
system
When
the
pressure
in
system
has
dropped
to
710
mm
Hg
28
in
Hg
fully
close
both
valves
of
manifold
gauge
7
The
above
operation
completes
evacuation
of
system
Next
charge
refrigerant
Refer
to
Charging
Refrig
erant
Page 503 of 537

Air
Conditioning
b
When
charging
hquefied
refrigerant
into
the
system
lith
the
can
turned
upside
down
to
reduce
charging
time
charge
it
only
through
high
pressure
valve
but
not
through
low
pressure
3
h
e
After
completion
of
charging
the
compressor
should
always
be
turn
ed
Several
times
manually
See
Figure
AC
22
t
UL
Q
v1ifl
j
AC739
Fig
A
C
22
ClUJrging
refrigerant
First
step
4
If
refrigerant
charging
speed
slows
down
charge
it
while
Iunning
the
compressor
for
ease
of
charging
After
having
taken
the
steps
up
to
3
above
proceed
with
charging
in
the
following
order
I
Shut
off
high
pressure
valve
of
manifold
gauge
back
into
refrigerant
can
and
can
may
explode
2
Run
the
engine
at
idling
speeds
about
1
500
rpm
3
Set
the
temperature
control
lever
and
fan
switch
at
maximum
cool
and
maximum
speed
respectively
4
Charge
refrigerant
while
con
trolling
low
pressure
gauge
reading
at
2
8
kgfcm2
40
psi
or
less
by
turning
in
or
out
low
pressure
valve
of
mani
fold
gauge
See
Figure
AC
23
Caution
Never
charge
refrigerant
through
high
pressure
side
of
sys
tem
since
this
will
force
refrigerant
t
AC740
Fig
A
C
23
Charging
refrigerant
Second
step
AC
14
5
When
refrigerant
can
is
empty
fully
close
both
Ives
of
manifold
gauge
and
replace
refrigerant
can
with
a
new
one
Before
opening
manifold
gauge
valve
to
charge
refrigerant
from
new
can
be
sure
to
purge
air
from
inside
charging
hose
6
Charge
the
specified
amount
of
refrigerant
into
system
by
weighing
charged
refrigerant
with
scale
Over
charging
will
cause
discharge
pressure
to
rise
AC255
Measure
the
amount
of
charged
refrigerant
with
a
scale
Make
a
note
of
the
amount
charged
from
can
Fig
AC
24
Measuring
refrigerant
Refrigerant
capacity
Unit
kg
lb
Refrigerant
Minimum
Maximum
R
12
0
7
1
5
0
9
2
0
Note
The
presence
of
bubbles
in
sight
glass
of
receiver
dryer
is
an
unsuitable
method
of
checking
the
amount
of
refrigerant
charged
in
system
The
state
of
the
bubbles
in
sight
glass
should
only
be
used
for
checking
whether
the
amount
of
charged
refrigerant
is
small
or
not
The
amount
of
charged
refrigerant
can
be
correctly
judged
by
means
of
discharge
pressure
Refer
to
Re
frigerant
Level
Check
Page 504 of 537

7
After
the
specified
amount
of
refrigerant
has
been
charged
into
sys
tem
close
manifold
gauge
valves
Then
detach
charging
hoses
from
service
valves
of
system
Be
sure
to
install
valve
cap
to
service
valve
8
Confirm
that
there
are
no
leaks
in
system
by
checking
with
a
leak
detec
tor
Refer
to
Checking
for
Leaks
Note
Conducting
a
performance
test
prior
to
removing
manifold
gauge
is
a
good
sen
ice
operation
Refer
to
Performance
Test
CHECKING
FOR
LEAKS
Conduct
a
leak
test
whenever
leak
age
of
refrigerant
is
suspected
and
when
conducting
service
operations
which
are
accompanied
by
disassembly
Dr
loosening
of
connection
fittings
Air
Conditioning
Refrigerant
is
a
colorless
odorless
gas
and
leakage
from
system
is
diffi
cult
to
detect
Accordingly
the
use
of
a
leak
detector
facilitates
check
for
leaks
Two
methods
of
checking
are
available
one
employs
a
halide
leak
detector
which
burns
propane
gas
or
butane
gas
and
the
other
is
an
electric
type
leak
detector
HALIDE
LEAK
DETECTOR
Since
the
propane
leak
detector
and
butane
leak
detector
are
the
same
in
respect
to
their
operation
this
section
describes
the
operation
of
the
propane
leak
detector
The
copper
screen
is
heated
by
the
burning
of
propane
Refrigerant
gas
decomposes
to
color
the
flame
when
it
contacts
the
heated
screen
The
gas
to
be
checked
is
drawn
into
the
sampling
tube
and
sent
out
to
the
burner
A
refrigerant
leak
can
clearly
be
detected
by
variations
in
the
color
of
the
flame
Propane
type
NO
LEAK
SMALL
LEAK
LARGE
LEAK
Greenish
blue
Yellow
Purple
AC010
1
Copper
reaction
plate
2
Flame
adjusting
lines
3
Burner
4
Sampling
tube
5
Strainer
6
Gas
bomb
7
Flame
adjuster
Fig
A
C
25
Checking
for
leak
Butane
type
Pale
blue
Bright
blue
Vivid
green
AC
15
I
Discharge
refrigerant
in
one
or
two
seconds
to
ascertain
that
system
has
a
sufficient
pressure
needed
for
leak
detection
Charge
with
04
kg
I
lb
of
refrigerant
if
necessary
2
Light
leak
detector
Adjust
the
height
of
the
ilame
between
flame
adjusting
lines
at
the
top
and
bottom
of
combustion
tube
A
reaction
plate
will
immediately
become
red
hot
3
Place
the
end
of
sampling
tube
near
the
point
of
the
suspected
leak
in
system
Notes
a
Since
refrigerant
gas
is
heavier
than
air
small
leaks
can
b
easily
detect
ed
by
placing
sampling
tube
direct
ly
below
the
check
point
b
Suitable
ventilation
is
required
If
refrigerant
gas
is
mixed
with
the
surrounding
air
leak
detector
will
always
indicate
a
response
and
detection
of
the
actual
leak
will
be
difficult
c
Never
bold
leak
detector
at
an
angle
Cautions
a
Never
inhale
the
fumes
produced
by
combustion
of
refrigerant
gas
since
they
are
toxic
b
Never
use
halide
torch
in
a
place
where
combustible
or
explosive
gas
is
present
4
The
ilame
will
be
almost
colorless
when
there
is
no
refrigerant
gas
being
burned
When
there
is
a
small
refriger
ant
gas
leak
the
ilame
will
be
green
or
yellowgreen
When
refrigerant
gas
leak
age
is
large
the
ilame
will
be
brilliant
blue
or
purple
Since
the
color
of
the
ilame
will
be
yellow
when
dust
is
being
burned
Or
there
is
aging
scale
on
copper
reaction
plate
always
keep
the
strainer
of
sampling
tube
and
reaction
plate
clean
5
Major
check
points
I
Compressor
Compressor
shaft
seal
rotate
the
compressor
by
hand
Oil
filler
plug
Flexible
hose
connections
Rear
cover
and
side
cover
gaskets
Service
valve
2
Condenser
Condenser
pipe
fitting
Condenser
inlet
and
outlet
pipe
connections
I