System DescriptionNBEL0027OUTLINENBEL0027S02Power is supplied at all times
Ito headlamp RH relay terminals 1 and 3
Ithrough 15A fuse (No. 59, located in the fuse and fusible link box), and
Ito headlamp battery saver control unit terminal 7
Ito smart entrance control unit terminal 10
Ithrough 7.5A fuse [No. 24, located in the fuse block (J/B)], and
Ito front fog lamp relay terminal 3
Ithrough 15A fuse (No. 53, located in the fuse and fusible link box).
When ignition switch is in ON or START position, power is supplied
Ito headlamp battery saver control unit terminal 1
Ithrough 10A fuse [No. 16, located in the fuse block (J/B)], and
Ito headlamp battery saver control unit terminal 10, and
Ito smart entrance control unit terminal 33
Ithrough 7.5A fuse [No. 11, located in the fuse block (J/B)].
Ground is supplied to headlamp battery saver control unit terminals 4 and 11.
When lighting system is in 2ND position, ground is supplied
Ito headlamp RH relay terminal 2 from headlamp battery saver control unit terminals 2 and 8
Ithrough headlamp battery saver control unit terminals 3 and 9,
Ithrough lighting switch terminal 12, and
Ithrough body grounds E13 and E41.
Headlamp RH relay is then energized.
FRONT FOG LAMP OPERATIONNBEL0027S01The front fog lamp switch is built into the combination switch. The lighting switch must be in the 2ND position
and LOW (ªBº) position for front fog lamp operation.
With the front fog lamp switch in the ON position, ground is supplied
Ito front fog lamp relay terminal 2
Ithrough the front fog lamp switch, lighting switch and body grounds E13 and E41.
The front fog lamp relay is energized and power is supplied
Ifrom front fog lamp relay terminal 5
Ito terminal 1 of each front fog lamp.
Ground is supplied to terminal 3 of each front fog lamp through body grounds E13 and E41.
With power and ground supplied, the front fog lamps illuminate.
BATTERY SAVER CONTROLNBEL0027S03When the ignition switch is turned from ON (or START) to OFF (or ACC) positions while front fog lamps are
illuminated, the RAP signal is supplied to terminal 10 of the headlamp battery saver control unit from smart
entrance control unit terminal 5.
After counting 45 seconds by the RAP signal from the smart entrance control unit to headlamp battery saver
control unit, the ground supply to terminal 2 of headlamp RH relay from headlamp battery saver control unit
teminals 2 and 8 are terminated.
Then front fog lamps are turned to off.
Front fog lamps are turned off when driver or passenger side door is opened even if 45 seconds have not
passed after the ignition switch is turned from ON (or START) to OFF (or ACC) positions while front fog lamps
are illuminated.
When the lighting switch is turned from OFF to 2ND after front fog lamps are turned off by the battery saver
control, ground is supplied
Ito headlamp battery saver control unit terminals 5 and 13 from lighting switch terminal 11, and
Ito headlamp RH relay terminal 2 from headlamp battery saver control unit terminals 2 and 8
Ithrough headlamp battery saver control unit terminals 3 and 9, and
Ithrough lighting switch terminal 12.
Then the front fog lamps illuminate again.
FRONT FOG LAMP
System Description
EL-70
Page 1260 of 2395

System DescriptionNBEL0030TURN SIGNAL OPERATIONNBEL0030S01With the hazard switch in the OFF position and the ignition switch in the ON or START position, power is sup-
plied
Ithrough 7.5A fuse [No. 12, located in the fuse block (J/B)]
Ito hazard switch terminal 2
Ithrough terminal 1 of the hazard switch
Ito combination flasher unit terminal 1
Ithrough terminal 3 of the combination flasher unit
Ito turn signal switch terminal 1.
Ground is supplied to combination flasher unit terminal 2 through body grounds M4, M66 and M147.
LH TurnNBEL0030S0101When the turn signal switch is moved to the LH position, power is supplied from turn signal switch terminal 3
to
Ifront fog lamp LH (turn signal) terminal 2
Icombination meter terminal 25
Irear combination lamp LH terminal 5.
Ground is supplied to the front fog lamp LH (turn signal) terminal 3 through body grounds E13 and E41.
Ground is supplied to the rear combination lamp LH terminal 6 through body grounds B11, B22 and D210.
Ground is supplied to combination meter terminal 30 through body grounds M4, M66 and M147.
With power and ground supplied, the combination flasher unit controls the flashing of the LH turn signal lamps.
RH TurnNBEL0030S0102When the turn signal switch is moved to the RH position, power is supplied from turn signal switch terminal
2to
Ifront fog lamp RH (turn signal) terminal 2
Icombination meter terminal 29
Irear combination lamp RH terminal 5.
Ground is supplied to the front fog lamp RH (turn signal) terminal 3 through body grounds E13 and E41.
Ground is supplied to the rear combination lamp RH terminal 6 through body grounds B55 and B75.
Ground is supplied to combination meter terminal 30 through body grounds M4, M66 and M147.
With power and ground supplied, the combination flasher unit controls the flashing of the RH turn signal lamps.
HAZARD LAMP OPERATIONNBEL0030S02Power is supplied at all times to hazard switch terminal 3 through:
I15A fuse [No. 20, located in the fuse block (J/B)].
With the hazard switch in the ON position, power is supplied
Ithrough terminal 1 of the hazard switch
Ito combination flasher unit terminal 1
Ithrough terminal 3 of the combination flasher unit
Ito hazard switch terminal 4.
Ground is supplied to combination flasher unit terminal 2 through body grounds M4, M66 and M147.
Power is supplied through terminal 5 of the hazard switch to
Ifront fog lamp LH (turn signal) terminal 2
Icombination meter terminal 25
Irear combination lamp LH terminal 5.
Power is supplied through terminal 6 of the hazard switch to
Ifront fog lamp RH (turn signal) terminal 2
Icombination meter terminal 29
Irear combination lamp RH terminal 5.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
TURN SIGNAL AND HAZARD WARNING LAMPS
System Description
EL-75
Page 1261 of 2395

Ground is supplied to terminal 3 of each front fog lamp (turn signal) through body grounds E13 and E41.
Ground is supplied to terminal 6 of the rear combination lamp LH through body grounds B11, B22 and D210.
Ground is supplied to terminal 6 of the rear combination lamp RH through body grounds B55 and B75.
Ground is supplied to combination meter terminal 30 through body grounds M4, M66 and M147.
With power and ground supplied, the combination flasher unit controls the flashing of the hazard warning
lamps.
MULTI-REMOTE CONTROL SYSTEM OPERATIONNBEL0030S03Power is supplied at all times
Ithrough 15A fuse [No. 20, located in the fuse block (J/B)]
Ito multi-remote control relay terminals 1, 3 and 6.
Ground is supplied to multi-remote control relay terminal 2, when the multi-remote control system is triggered
through the smart entrance control unit.
Refer to ªMULTI-REMOTE CONTROL SYSTEMº, EL-270.
The multi-remote control relay is energized.
Power is supplied through terminal 7 of the multi-remote control relay
Ito front fog lamp LH (turn signal) terminal 2
Ito combination meter terminal 25
Ito rear combination lamp LH terminal 5.
Power is supplied through terminal 5 of the multi-remote control relay
Ito front fog lamp RH (turn signal) terminal 2
Ito combination meter terminal 29
Ito rear combination lamp RH terminal 5.
Ground is supplied to terminal 3 of each front fog lamp (turn signal) through body grounds E13 and E41.
Ground is supplied to terminal 6 of the rear combination lamp LH through body grounds B11, B22 and D210.
Ground is supplied to terminal 6 of the rear combination lamp RH through body grounds B55 and B75.
Ground is supplied to combination meter terminal 30 through body grounds M4, M66 and M147.
With power and ground supplied, the smart entrance control unit controls the flashing of the hazard warning
lamps.
TURN SIGNAL AND HAZARD WARNING LAMPS
System Description (Cont'd)
EL-76
Page 1264 of 2395

Trouble DiagnosesNBEL0033
Symptom Possible cause Repair order
Turn signal and hazard warning
lamps do not operate.1. Hazard switch
2. Combination flasher unit
3. Open in combination flasher
unit circuit1. Check hazard switch.
2. Refer to combination flasher unit check.
3. Check wiring to combination flasher unit for open
circuit.
Turn signal lamps do not operate
but hazard warning lamps operate.1. 7.5A fuse
2. Hazard switch
3. Combination switch (turn signal)
4. Open in combination switch
(turn signal) circuit1. Check 7.5A fuse [No. 12, located in fuse block
(J/B)]. Turn ignition switch ON and verify battery
positive voltage is present at terminal 2 of hazard
switch.
2. Check hazard switch.
3. Check combination switch (turn signal).
4. Check the wire between combination flasher unit
terminal 3 and combination switch (turn signal) ter-
minal 1 for open circuit.
Hazard warning lamps do not oper-
ate but fog lamps (turn signal)
operate.1. 15A fuse
2. Hazard switch
3. Open in hazard switch circuit1. Check 15A fuse [No. 20, located in fuse block (J/B)].
Verify battery positive voltage is present at terminal
3 of hazard switch.
2. Check hazard switch.
3. Check the wire between combination flasher unit
terminal 3 and hazard switch terminal 4 for open cir-
cuit.
Front fog lamp (turn signal) LH or
RH does not operate.1. Bulb
2. Grounds E13 and E41
3. Open in front fog lamp (turn sig-
nal) circuit1. Check bulb.
2. Check grounds E13 and E41.
3. Check harness between front fog lamp (turn signal)
and combination switch.
Rear combination lamp LH does
not operate.1. Bulb
2. Grounds B11, B22 and D210
3. Open in rear combination lamp
LH circuit1. Check bulb.
2. Check grounds B11, B22 and D210.
3. Check harness between rear combination lamp LH
and hazard switch.
Rear combination lamp RH does
not operate.1. Bulb
2. Grounds B55 and B75
3. Open in rear combination lamp
RH circuit1. Check bulb.
2. Check grounds B55 and B75.
3. Check harness between rear combination lamp RH
and hazard switch.
LH and RH turn indicators do not
operate.1. Ground 1. Check grounds M4, M66 and M147.
LH or RH turn indicator does not
operate.1. Bulb
2. Open in turn indicator circuit1. Check bulb in combination meter.
2. Check harness between combination meter and haz-
ard switch.
SEL122E
Electrical Components InspectionNBEL0034COMBINATION FLASHER UNIT CHECKNBEL0034S01IBefore checking, ensure that bulbs meet specifications.
IConnect a battery and test lamp to the combination flasher
unit, as shown. Combination flasher unit is properly function-
ing if it blinks when power is supplied to the circuit.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
TURN SIGNAL AND HAZARD WARNING LAMPS
Trouble Diagnoses
EL-79
Page 1265 of 2395

System DescriptionNBEL0035The illumination lamp operation is controlled by the lighting switch which is built into the combination switch
and headlamp battery saver control unit. The battery saver system is controlled by the headlamp battery saver
control unit and smart entrance control unit.
Power is supplied at all times
Ito tail lamp relay terminals 2 and 3
Ithrough 10A fuse (No. 61, located in the fuse and fusible link box), and
Ito headlamp battery saver control unit terminal 7, and
Ito smart entrance control unit terminal 10
Ithrough 7.5A fuse [No. 24, located in the fuse block (J/B)].
When ignition switch is in ON or START position, power is supplied
Ito headlamp battery saver control unit terminal 1
Ithrough 10A fuse [No. 16, located in the fuse block (J/B)], and
Ito headlamp battery saver control unit terminal 10, and
Ito smart entrance control unit terminal 33
Ithrough 7.5A fuse [No. 11, located in the fuse block (J/B)].
Ground is supplied to headlamp battery saver control unit terminals 4 and 11.
LIGHTING OPERATION BY LIGHTING SWITCHNBEL0035S01When lighting switch is 1ST (or 2ND) position, ground is supplied
Ito tail lamp relay terminal 1 from headlamp battery saver control unit terminals 6 and 14
Ithrough headlamp battery saver control unit terminals 5 and 13, and
Ithrough body grounds E13 and E41.
Tail lamp relay is then energized and illumination lamps illuminate.
The lighting switch must be in the 1ST or 2ND position for illumination.
LIGHTING OPERATION BY AUTO LIGHT CONTROL SYSTEMNBEL0035S03When auto light operation is operated, ground is supplied
Ito tail lamp relay terminal 1 from headlamp battery saver control unit terminals 6 and 14
Ithrough headlamp battery saver control unit terminals 5 and 13, and
Ithrough auto light control unit terminal 7.
Tail lamp relay is then energized and the illumination lamps illuminate.
The illumination control switch that controls the amount of current to the illumination system. As the amount
of current increases, the illumination becomes brighter.
The following chart shows the power and ground connector terminals for the components included in the illu-
mination system.
Component Connector No. Power terminal Ground terminal
Illumination control switch M19 1 3
4WD shift switch M141 7 8
Ashtray M54 1 2
A/T indicator B59 3 4
Cigarette lighter M57 3 4
Audio unit M48 8 7
Compass and thermometer R4 5 2
Hazard switch M35 7 8
Rear window defogger switch M36 5 6
Headlamp aiming switch M16 3 4
Power window main switch D6 16 18
Front power window switch RH D36 10 17
ILLUMINATION
System Description
EL-80
Page 1266 of 2395

Component Connector No. Power terminal Ground terminal
IVCS switch R10 2 12
Display & NAVI control unit M117, M118 8 24
A/C auto amp. M102 24 25
Clock M39 3 4
Globe box lamp M30 1 2
The ground for all of the components except for compass, glove box lamp and ashtray are controlled through
terminals 2 and 3 of the illumination control switch and body grounds M77 and M111.
BATTERY SAVER CONTROLNBEL0035S02When the ignition switch is turned from ON (or START) to OFF (or ACC) positions while illumination lamps
are illuminated, the RAP signal is supplied to terminal 10 of the headlamp battery saver control unit from smart
entrance control unit terminal 5.
After counting 45 seconds by the RAP signal from the smart entrance control unit to headlamp battery saver
control unit, the ground supply to terminal 1 of the tail lamp relay from headlamp battery saver control unit
teminals 6 and 14 is terminated.
Then illumination lamps are turned off.
Illumination lamps are turned off when driver or passenger side door is opened even if 45 seconds have not
passed after the ignition switch is turned from ON (or START) to OFF (or ACC) positions while illumination
lamps are illuminated.
When the lighting switch is turned from OFF to 1ST (or 2ND) after illumination lamps are turned off by the
battery saver control, ground is supplied
Ito headlamp battery saver control unit terminals 5 and 13 from lighting switch terminal 11, and
Ito tail lamp relay terminal 1 from headlamp battery saver control unit terminals 6 and 14.
Then illumination lamps illuminate again.
NOTE:
For Trouble Diagnoses for battery saver control, refer to ªPARKING, LICENSE AND TAIL LAMPSº
(EL-66).
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
ILLUMINATION
System Description (Cont'd)
EL-81
Page 1273 of 2395
![INFINITI QX4 2001 Factory Service Manual System DescriptionNBEL0038POWER SUPPLY AND GROUNDNBEL0038S06Power is supplied at all times:
Ithrough 7.5A fuse [No. 24, located in the fuse block (J/B)]
Ito key switch terminal 2 and
Ito smart entranc INFINITI QX4 2001 Factory Service Manual System DescriptionNBEL0038POWER SUPPLY AND GROUNDNBEL0038S06Power is supplied at all times:
Ithrough 7.5A fuse [No. 24, located in the fuse block (J/B)]
Ito key switch terminal 2 and
Ito smart entranc](/img/42/57027/w960_57027-1272.png)
System DescriptionNBEL0038POWER SUPPLY AND GROUNDNBEL0038S06Power is supplied at all times:
Ithrough 7.5A fuse [No. 24, located in the fuse block (J/B)]
Ito key switch terminal 2 and
Ito smart entrance control unit terminal 10.
When the key is removed from ignition key cylinder, power is interrupted:
Ithrough key switch terminal 1
Ito smart entrance control unit terminal 32.
With the ignition key switch in the ON or START position, power is supplied:
Ithrough 7.5A fuse [No. 11, located in the fuse block (J/B)]
Ito smart entrance control unit terminal 33.
Ground is supplied:
Ito smart entrance control unit terminal 16
Ithrough body grounds terminals M77 and M111.
When the front driver side door is opened, ground is supplied:
Ithrough body grounds B11, B22 and D210
Ito front door switch (LH) terminal 2
Ifrom front door switch (LH) terminal 1
Ito smart entrance control unit terminal 29.
When the front passenger side door is opened, ground is supplied:
Ithrough case ground of front door switch (RH)
Ifrom front door switch (RH) terminal 1
Ito smart entrance control unit terminal 40.
When any other door (except front door) is opened, ground is supplied to smart entrance control unit termi-
nal 28 in the same manner as the front door switch (front passenger side).
When the front driver side door is unlocked, the smart entrance control unit receives a ground signal:
Ithrough body grounds terminals M77 and M111
Ito front door lock actuator (driver side unlock sensor) terminal 2
Ifrom front door lock actuator (driver side unlock sensor) terminal 4
Ito smart entrance control unit terminal 36.
When a signal, or combination of signals is received by the smart entrance control unit, ground is supplied:
Ithrough smart entrance control unit terminal 8
Ito interior lamp terminal 2.
With power and ground supplied, the interior lamp illuminates.
SWITCH OPERATIONNBEL0038S07When interior lamp switch is ON, ground is supplied:
Ithrough case grounds of interior lamp
Ito interior lamp.
And power is supplied:
Ito interior lamp terminal 1
Ifrom smart entrance control unit terminal 17.
When spot lamp (LH and/or RH) is ON, ground is supplied:
Ithrough body grounds M4, M66 and M147
Ito spot lamp terminal 2.
And power is supplied:
Ito spot lamp terminal 1
Ifrom smart entrance control unit terminal 17.
When vanity mirror illumination (LH and/or RH) is ON, ground is supplied:
Ithrough body grounds M4, M66 and M147
Ito vanity mirror illuminations (LH and RH) terminals 2.
INTERIOR, SPOT, VANITY MIRROR AND LUGGAGE ROOM LAMPS
System Description
EL-88
Page 1274 of 2395

And power is supplied:
Ito vanity mirror illuminations (LH and RH) terminals 1
Ifrom smart entrance control unit terminal 17.
With power and ground supplied, interior lamps turn ON.
INTERIOR LAMP TIMER OPERATIONNBEL0038S08When interior lamp switch is in the ªDOORº position, the smart entrance control unit keeps the interior lamp
illuminated for about 30 seconds when:
Iunlock signal is supplied from driver's door unlock sensor while all doors are closed and key is removed
from ignition key cylinder
Iunlock signal is supplied from multi-remote controller while all doors are closed and driver's door is locked
Ikey is removed from ignition key cylinder while all doors are closed
Idriver's door is opened and then closed while key is removed from the iginition key cylinder. (However, if
the driver's door is closed with the key insered in the ignition key cylinder after the driver's door is opened
with the key removed, the timer is operated.)
The timer is canceled when:
Idriver's door is locked,
Idriver's door is opened, or
Iignition switch is turned ON.
ON-OFF CONTROLNBEL0038S09When the driver side door, front passenger door, rear LH, RH door or back door is opened, the interior room
lamp turns on while the interior room lamp switch is in the ªDOORº position.
BATTERY SAVERNBEL0038S10The lamp turns off automatically when interior lamp, luggage room lamp, spot lamp and/or vanity mirror illu-
mination is illuminated with the ignition key is in OFF position, if the lamp remains lit by the door switch open
signal or if the lamp switch is in ON position for more than 10 minutes.
After lamps turn OFF by the battery saver system, the lamps illuminate again when:
Idriver's door is locked or unlocked,
Idoor is opened or closed,
Ikey is inserted or removed in ignition key cylinder.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTERIOR, SPOT, VANITY MIRROR AND LUGGAGE ROOM LAMPS
System Description (Cont'd)
EL-89
Page 1280 of 2395
![INFINITI QX4 2001 Factory Service Manual POWER SUPPLY AND GROUND CIRCUITNBEL0042S08Power is supplied at all times
Ithrough 7.5A fuse [No. 24, located in the fuse block (J/B)]
Ito combination meter terminal 62.
With the ignition switch in the INFINITI QX4 2001 Factory Service Manual POWER SUPPLY AND GROUND CIRCUITNBEL0042S08Power is supplied at all times
Ithrough 7.5A fuse [No. 24, located in the fuse block (J/B)]
Ito combination meter terminal 62.
With the ignition switch in the](/img/42/57027/w960_57027-1279.png)
POWER SUPPLY AND GROUND CIRCUITNBEL0042S08Power is supplied at all times
Ithrough 7.5A fuse [No. 24, located in the fuse block (J/B)]
Ito combination meter terminal 62.
With the ignition switch in the ON or START position, power is supplied
Ithrough 10A fuse [No. 8, located in the fuse block (J/B)]
Ito combination meter terminal 66.
Ground is supplied
Ito combination meter terminal 59
Ithrough body grounds M4, M66 and M147.
WATER TEMPERATURE GAUGENBEL0042S01The water temperature gauge indicates the engine coolant temperature. The reading on the gauge is based
on the resistance of the thermal transmitter.
As the temperature of the coolant increases, the resistance of the thermal transmitter decreases. A variable
ground is supplied to terminal 18 of the combination meter for the water temperature gauge. The needle on
the gauge moves from ªCº to ªHº.
TACHOMETERNBEL0042S02The tachometer indicates engine speed in revolutions per minute (rpm).
The tachometer is regulated by a signal
Ifrom terminal 25 of the ECM
Ito combination meter terminal 16 for the tachometer.
FUEL GAUGENBEL0042S03The fuel gauge indicates the approximate fuel level in the fuel tank.
The fuel gauge is regulated by a variable ground signal supplied
Ito combination meter terminal 17 for the fuel gauge
Ifrom terminal 3 of the fuel level sensor unit
Ithrough terminal 2 of the fuel level sensor unit and
Ithrough body grounds B11, B22 and D210.
SPEEDOMETERNBEL0042S04The vehicle speed sensor provides a voltage signal to the combination meter for the speedometer.
The voltage is supplied
Ifrom combination meter terminal 15 for the speedometer
Ito terminal 2 of the vehicle speed sensor.
The speedometer converts the voltage into the vehicle speed displayed.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
METERS AND GAUGES
System Description (Cont'd)
EL-95
Page 1288 of 2395

SEL179WB
POWER SUPPLY AND GROUND CIRCUIT CHECK=NBEL0201S03Power Supply Circuit CheckNBEL0201S0301
Terminals Ignition switch position
(+) (þ) OFF ACC ON
62 GroundBattery
voltageBattery
voltageBattery
voltage
66 Ground 0V 0VBattery
voltage
If NG, check the following.
I10A fuse [No. 12, located in fuse block (J/B)]
I10A fuse [No. 30, located in fuse block (J/B)]
IHarness for open or short between fuse and combination
meter
SEL180WA
Ground Circuit CheckNBEL0201S0302
Terminals Continuity
59 - Ground Yes
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
METERS AND GAUGES
Trouble Diagnoses (Cont'd)
EL-103