elec INFINITI QX4 2001 Factory Service Manual

INFINITI QX4 2001 Factory Service Manual QX4 2001 INFINITI INFINITI https://www.carmanualsonline.info/img/42/57027/w960_57027-0.png INFINITI QX4 2001 Factory Service Manual

Page 755 of 2395

INFINITI QX4 2001  Factory Service Manual DTC Confirmation ProcedureNBEC0112CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If ªDTC Confirmation Procedureº has been previously conducted,
always turn ignition switch ªOFFº and wait at

Page 760 of 2395

INFINITI QX4 2001  Factory Service Manual 5 CLEAR THE SELF-LEARNING DATA
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªSELF-LEARNING CONTº in ªWORK SUPPORTº mode with CONSULT-II.
3. Clear the s

Page 764 of 2395

INFINITI QX4 2001  Factory Service Manual 11 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº

Page 767 of 2395

INFINITI QX4 2001  Factory Service Manual TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
62 G/BHeated oxygen sensor
1 (front) (bank 2)[Engine is running]
IWarm-up condition
IEngine speed is 2,000 rpm.0 - Approximately 1.0V (Peri-
od

Page 768 of 2395

INFINITI QX4 2001  Factory Service Manual 5) Restart engine and let it idle for 25 seconds.
6) If 1st trip DTC is detected, go to ªDiagnostic Procedureº,
EC-236.
WITH GSTNBEC0120S021) Start engine and warm it up to normal operating temperat

Page 773 of 2395

INFINITI QX4 2001  Factory Service Manual 5 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº

Page 776 of 2395

INFINITI QX4 2001  Factory Service Manual On Board Diagnosis LogicNBEC0126Malfunction is detected when the current amperage in the heated
oxygen sensor 1 heater (front) circuit is out of the normal range.
[An improper voltage drop signal is s

Page 783 of 2395

INFINITI QX4 2001  Factory Service Manual Possible CauseNBEC0438IHarness or connectors
(The sensor circuit is open or shorted.)
IHeated oxygen sensor 2 (rear)
IFuel pressure
IInjectors
SEF340Z
SEF341Z
SEF342Z
DTC Confirmation ProcedureNBEC013

Page 787 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0137
1 RETIGHTEN GROUND SCREWS
1. Turn ignition switch ªOFFº.
2. Loosen and retighten engine ground screws.
SEF959Y
©GO TO 2.
2 CLEAR THE SELF-LEARNING DATA
With CONSULT-II

Page 789 of 2395

INFINITI QX4 2001  Factory Service Manual 4 CHECK HO2S2 (REAR) GROUND CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between HO2S2 terminal 4 and engine ground.
Refer to Wiring Diagram.
Continuity should exist.
2. Also check harness f