JAGUAR X308 1998 2.G Workshop Manual

JAGUAR X308 1998 2.G Workshop Manual X308 1998 2.G JAGUAR JAGUAR https://www.carmanualsonline.info/img/21/7640/w960_7640-0.png JAGUAR X308 1998 2.G Workshop Manual
Trending: timing chains, door panel, warning lights, ECO mode, engine oil, tcm, regulator torque

Page 1891 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
suppression module positive cable from the positive 
terminal. 
3. Where fitted, remove  the nut which secures the 
suppression module negati ve cable and disconnect 
the cable from the generator. R

Page 1892 of 2490

JAGUAR X308 1998 2.G Workshop Manual Installation 
 
 
13. Move the spacing bush rearward s slightly in the generator 
mounting bracket, to ease fitting the new generator. 
1. Position a suitable length  bolt through the bush, fit a 
tub

Page 1893 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
 
 
2. Secure the suppression module positive cable and 
main positive cable to  the generator positive 
terminal. 
3. Fit the boot to the terminal. 
4. Reconnect the generator harness multi-plug.

Page 1894 of 2490

JAGUAR X308 1998 2.G Workshop Manual Generator and Regulator - Generator4.0L SC V8 - AJ26 
Removal and Installation 
Removal 
 
1. Disconnect the batt ery ground cable. 
Remove the battery cover.  
2.  Remove the air cleaner assembly

Page 1895 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
1. Disconnect the harness multi-plug. 
2. Remove the protective boot from the positive 
terminal, remove the termin al nut and disconnect the 
cable from the terminal. 
 
11.  Remove the lower mount

Page 1896 of 2490

JAGUAR X308 1998 2.G Workshop Manual Installation 
 
 
15. Change the position of the ge nerator and remove it upwards 
between the engine and the radiator. 
 
16.  Move the spacing bush rearward s slightly in the generator 
mounting bra

Page 1897 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
2. Fit the lower mounting bolt and nut, tighten to 38-48 
Nm. 
 
3.  Connect the harness. 
1. Secure the main positive cable to the generator positive terminal. 
2. Fit the boot to the terminal. 
3.

Page 1898 of 2490

JAGUAR X308 1998 2.G Workshop Manual  
 
 
1415) on the centre bolt of the belt tensioner idler 
pulley, rotate the adjuster  against spring tension. 
3. Whilst holding the tensioner against spring tension,  pass the drive belt over the

Page 1899 of 2490

JAGUAR X308 1998 2.G Workshop Manual Generator and Regulator - Voltage Regulator 
Removal and Installation 
Removal 
 
1. Disconnect the batt ery ground cable. 
Remove the battery cover.  
2.  Remove the generator from the  vehicle. R

Page 1900 of 2490

JAGUAR X308 1998 2.G Workshop Manual Installation 
 
 
6. Remove the rubber cover from the brush holder. 
 
7. Remove the screws  which secure the brush holder. 
Remove the brush holder, taking care not to damage 
the brushes.  
 
8.
Trending: oil dipstick, idler, stop start, fuel, FRONT DOOR, alarm, air conditioning