MAZDA 232 1990 Suplement Owners Manual
Manufacturer: MAZDA, Model Year: 1990, Model line: 232, Model: MAZDA 232 1990Pages: 677, PDF Size: 61.19 MB
Page 91 of 677

E tNDEX
INDEX
-
- &ANT RESERVOlR
ENGiNE COOLANT
TOTAL CAPACITY
MTX: 5.0 liters (5.3 US qt, 4.4 Imp qt)
ATX: 6.0 liters (6.3 US qt. 5.3
tmp qt)
1. Fan motor
Inspection .._.....,._............._..........
page E-1 I
E-Z
Page 92 of 677

INDEX E
BP DOHC TURBO
III 6 No.2 AND No.3 RELAY
1. Thermostat 4. Water thermoswitch
Inspection ...................................
page E- 9 inspection ...................................
page E-l 1
2. Electric cooling fan system 5. Radiator thermoswitch
System
inspection .......................
page E-l 0 Removal I Inspection I
3. Fan motor Instailation .................................
page E-1 2
Inspection ...................................
page E-l 1 6 Fan relay
Removal I Inspection .................. page E-1 3
E-3
Page 93 of 677

E OUTLINE
OUTLINE
OUTttNE OF CONSTRUCTION
The cooling system in the 323 4WD model is basically the same as in the 323 2WD model.
Although there is no fundamental change from the BP DOHC of the 2WD model, the coolant circulation
path has been changed to direct coolant to the water-cooied turbocharger.
A two-stage thermostat is used in the BP DUHC turbocharged engine to stabilize the engine coolant tem-
peratu re.
The radiator and cooling fan specifications are different. The BP DOHC turbocharged engine of the 4WD
model uses a two-speed electric cooling fan.
93GOEX-704
COOLANT FLOW CHART (BP DOHC TURBO)
E-4
Page 94 of 677
![MAZDA 232 1990 Suplement Owners Manual SPECIFICATlONS
-
km
Cootlng system
Coolant camacltv
EnginelTtansaxte
lrters [US Qt. Imo at)
8P SOHC ] 8P DOW Turbo
MTX ATX
I MTX
Water-cooled, forced crrculation
5.0 (5.3, 4.4)
I 6.0 t&3,5 MAZDA 232 1990 Suplement Owners Manual SPECIFICATlONS
-
km
Cootlng system
Coolant camacltv
EnginelTtansaxte
lrters [US Qt. Imo at)
8P SOHC ] 8P DOW Turbo
MTX ATX
I MTX
Water-cooled, forced crrculation
5.0 (5.3, 4.4)
I 6.0 t&3,5](/img/28/57056/w960_57056-93.png)
SPECIFICATlONS
-
km
Cootlng system
Coolant camacltv
EnginelTtansaxte
lrters [US Qt. Imo at)
8P SOHC ] 8P DOW Turbo
MTX ATX
I MTX
Water-cooled, forced crrculation
5.0 (5.3, 4.4)
I 6.0 t&3,5.3) -
1 Type
Water puma 1
I Water seal Centrifugal
Unified mechanical
seal
: Type I Wax,single stage”‘, Wax, two-stage*’ 1 Wax, two-stage
80.5-83.5 (177-182)“1
Opening temperature
“C (OF)
Main: 86.5-89.5 (188-l 93) *’ Main: 86.5-89.5 (lSS--193)
The:mosta! 1 Sub : 83.5-86.5 (182-188) Sub 83.G86.5 (182-188)
1 Full-open temperature OC
(OF) 95 (203)*‘, 100 (212)*’ i 100 (212)
L I
“...Except cold area, *2...Cotd area only
1 r 1 93GOEX-706 j Full-open lift mm (in) 8.5 (0.335) or more’l
Main: 8.0 (0.31).mln.‘2
Sub : 1.5 10.061 min * Main: 8.0 (0.31) min.
Sub : I.5 (0.06) mm.
Radiator 1 Type
Cap vaive opening-pressure ’
kPa (kglcm2, psi) Corrugated fin
74-l 03 (0.75-I .05, 11-l 5) j Tvm?
EIectnc I
Coohg fan f Outer drameter mm (in) 320 (12.6) 340 (13.4)
Blade
Number 4 5
Motor
/ Current A
6.6 * 1 Hi : 13.3 + 10% max.
Lo: 8.8 + 10% max. E-5
Page 95 of 677

E OUTlANE
TWO-STAGE THERMOSTAT (BP DOHC TURBO)
MAIN VALVE
SINGLE-STAGE THERMOSTAT
(AMBIENT fEMP. -20% (4*f))
NTRANCE PORT TEMP
GINE EXIT PORT TEMP.
- 100 km/h
60 kndh
(63 mph) ~~~~~ (38 mph)
TWO-STAGE THERMOSTAT
A sub-valve is incorporated in the thermostat to stabilize the coolant temperature in the engine, to improve
cold weather performance, and to reduce heater output temperature fluctuations as noted in the diagram.
Operation
Stage 1
During cold weather operation, 83.5*C [182°F]-86.50C [t 88OF] only the sub-valve opens to control the
engine coolant temperature.
Stage 2
During normal operation, 86.5OC (1 88°F)-89.50C (I 93OF) the main valve opens to permit increased coul-
an: flow through the radiator.
E-6
Page 96 of 677

RADIATOR AND COOLING FAN
The radiator and cooling fan specifications are revised.
Specifications
r
EnginelTransaxle BP SOHC 1 BP DOHC Turbo
ATX I
Item MTX MTX 1 Radiator I
Width 647 +
+
Core size
mm (in) H etght 390 t *-
Depth 16 25 e
Fm pnch
mm (in) 1.3 t c
Heat dissipaton capacity kcallh
38,800 43,800 C
Type -
Double tube - Transaxle oil cooler
Heat dissipation capacity
-
kcal/h I 1,650 -
Cooling fan
Number of biades
4 5 +
Outer drameter
mm (in> 320
340 C
Capacity
w-v 80-12 160-12 c
Current
A
1 I 6.6 * 1 Hi : 13.3 + 7 0% max. + Lo: 8.8 + 10% max.
93GOEX-708
OIL COOLER (ATX
;ECTION A-A
4WD MODEL ZWD MODEL
I
DEPTH E-7
Page 97 of 677

E OUTLINE
ELECTRIC COCUNG FAN SYSTEM (BP DOHC TURBO)
System Circuit
I I
WITH A/C
r----‘-- -___- ---------.--------;
ADDITIONAL
FAN
MOTOR
I
II 1 A/C RELAY
RAD1ATdTHERMOSWITCH
ABOVE 105% I221 OF-): ON +IIAGNOSlS
CONNECTOR
WATER
THERMOSWlTCH
ABOVE 97% (207OF): ON
Operation 1. When the coolant temperature exceeds 97OC (207*F), the water thermoswitch turns ON to close the No.7
relay, and connects the + I and -1 terminals of the fan motor
connector. The fan motor turns at low
speed (about 1,660 rpm).
2. When the coolant temperature exceeds 105OC (221 OF), the radiator thermoswitch turns ON, to close the
No.2 and No.3 relays, and connects
the +2 and -2 terminals of the fan motor connector. The fan mo-
tor turns at high speed (about 2,200 rpm).
3. if the vehicle is equipped with air conditioning, the cooling fan motor operates whenever the
NC switch
and the blower switch are on, regardless of
the coolant temperature. Also, when the A/C switch and the blower switch are on, the A/C retay closes
to operate the additional fan
motur.
Note
l The water thermoswitch and the cooling fan reIay are normally-open switches.
Checking cooling fan operation 1. Jump across the TFA and the GND terminals
of the diagnosis connector with a jumper wire.
2. Turn the ignition switch to ON and verify that the cooling fan operates smoothly.
Note
l When the water thermoswitch connector is disconnected, the cooling fan wiif not operate.
E-8
Page 98 of 677

SUPPLEMENTAL SERVICE INFORMAT1ON, THERMOSTAT E
SUPPLEMENTAL SERVICE INFURMATtON
The following points in the section are changed in comparison with Workshop Manual [Europe (1203-l 0-89F),
Australia (I 204-I 0-89f)].
Thermostat (BP DUHC Turbo only)
l Inspection
Electric cooling fan system (BP DOHC Turbo only)
l System inspection
Fan motor
l 1 nspection
Water thermoswitch (BP DOHC Turbo only)
l tnspection
Radiator thermoswitch (BP DOHC Turbo only)
l Removal I Inspection I Installation
Fan relay (BP DOHC Turbo only)
l Removal ! Inspection 93GOEX-710
-
THERMOSTAT (BP DOHC TURBO)
SUB-V E
‘A
/ INSPECTKM
1. Visually check that the thermostat valve is airtight.
2. Place the thermostat and a thermometer in water.
3. Heat the water and check the following:
Initial-opening temperature:
Main: 86.5-89.5% (188--t93°F)
Sub : 83.5-86.5OC (f82--f88QF)
Full-open temperature: 100°C (212°F)
Full-open lift
Main: 8.Umm CU.31 in) min.
Sub : f.5mm (0.06 in) min.
E-9
Page 99 of 677

E ELECTRIC COOLING FAN SYSTEM
ELECTRIC COOLING FAN SYSTEM (BP
DUHC TURBO)
SYSTEM ClRCUIT
r
WITH A/C
r-- _______ ------
I ADDITIONAL
1 FAN
I PRESSL
SWITCH
I WATER
THERMOSWfTCtl
ABOVE 87OC (207OF): ON
RADlATOjl THERMOSWITCH
ABOVE 105*C (221 “I=): ON
8 93GOEX-719
-
%
J--- QY- -THERMOME?ERsi-=i
--
--------L-
93GOEX-7 i 2
E-10 SYSTEM INSPECTION
1. Jump across the test fan (TFA) terminal and the ground
(GN D) terminal of the diagnosis connector.
2. Turn the ignition switch ON and verify that the fan operates.
If the fan does not operate, inspect the cooling fan system
components and wiring harness.
3. Remove the radiator cap and place a thermometer in the
radiator filler neck.
4. Start the engine.
5. Verify that the fan operates when the coolant temperature
reaches approx. 97*C (207°F).
If it does, check the water thermoswitch.
(Refer to page
E--i I.)
Page 100 of 677

FAN MOTOR, WATER THERMOSWITCH E
93GOEX-71:
93GOEX-714
93GOEX-720
tNSPECTlON
Single-speed Type (For BP SOW MTX)
I. Verify
that the battery is fully charged.
2. Disconnect the fan motor connector.
3. Connect the battery and an ammeter to the fan motor
con-
nector.
4. Verify that current is as specified.
Current (A): 6.6 k 1
5. If current is not within specification and/or the fan does not
turn smoothly, replace the fan motor.
Two-speed Type (Except BP SUHC MTX)
I. Verify that the battery is fully charged.
2. Disconnect the fan motor connector.
3. Connect the battery and an ammeter to the fan motor con-
nectors for low-speed inspection.
4. Verify that the fan motor operates smoothly at the standard
cu vent.
Current (A): 8.8 + 10% max.
5. Connect the battery, an ammeter, and switch to the fan mo-
tor connectors for high-speed inspection.
6. Verify that the fan motor operates smoothly
at the standard
current or less with the switch ON.
Current (A): 13.3 + 10% max.
7. If not as specified, replace the fan motor.
WATER THERMOSWITCH
(BP DOHC TURBO)
INSPECTlUN
I . Place the switch and a thermometer in water.
2. Heat the water gradually and check continuity of the switch
with an ohmmeter.
Coolant temperature OC (OF) 1 Contrdy
I
More than 97 (207) Yes
Less than 90 (194)
NO
3. If not as specified, replace the water thermoswitch.
93GOEX.715