heater MAZDA 6 2002 Suplement Owner's Guide
[x] Cancel search | Manufacturer: MAZDA, Model Year: 2002, Model line: 6, Model: MAZDA 6 2002Pages: 909, PDF Size: 17.16 MB
Page 865 of 909

U–2
OUTLINE
OUTLINE OF CONSTRUCTIONA6E850201038201•The construction and operation of the air conditioner system is essentially carried over from that of the previous
Mazda6 (GG) model, except for the following features. (See Mazda6 Training Manual 3359-1*-02C.)
End Of Sie
FEATURESA6E850201038202Improved Comfort
•The water heater system has been adopted. (For MZR-CD (RF Turbo) European (L.H.D.) specs.)
End Of Sie
SPECIFICATIONSA6E850201038203Manual Air Conditioner
OUTLINE
ItemSpecification
L3, L8, LF MZR-CD (RF Turbo)
Heating capacity (kW {kcal/h}) 4.400 {3,784}4.400 {3,784} (L.H.D.)
5.120 {4,403} (R.H.D.)
Airflow volume
(during heater operation)Blower motor
(m
3/h)310 (L.H.D.)
300 (R.H.D.)
Electricity consumption
(during heater operation)Blower motor (W) 184
Cooling capacity (kW {kcal/h}) 4.200 {3,612}
Airflow volume (during air
conditioner operation)Blower motor
(m
3/h)460
Electricity consumption
(during air conditioner
operation)Blower motor (W) 225
Magnetic clutch (W) 46 45
Fan type Blower motor Sirocco fan
RefrigerantType R-134a
Regular amount
(approximate quantity)470 {16.6} (L.H.D.)
430 {15.2} (R.H.D.)
(g {oz})
A/C compressorType Vane-rotary
Discharge capacity
120 {120, 4.06}
(ml {cc, fl oz})
Max. allowable speed
6,400
(rpm)
Lube
oilType ATMOS GU10
Sealed volume
(approximate quantity)
120 {120, 4.06} 150 {150, 5.07}
(ml {cc, fl oz})
Magnetic clutch clearance
0.3—0.5 {0.012—0.019}
(mm {in})
CondenserType Multiflow (sub-cooling type)
Radiated heat (kW {kcal/h})4.69 {4,030}: European (L.H.D.) specs.
5.96 {5,130}: European (U.K.), GCC specs.
Receiver/drier
capacity(ml {cc, fl oz}) 190 {190, 6.42}
Desiccant Synthetic zeolite
Expansion valve Type Block type
Evaporator Type Double-tank drawn cup
Page 867 of 909

U–4
OUTLINE
Full-auto Air Conditioner
ItemSpecification
L3, L8, LF MZR-CD (RF Turbo)
Heating capacity (kW {kcal/h}) 4.400 {3,784}4.400 {3,784} (L.H.D.)
5.120 {4,403} {R.H.D.)
Airflow volume
(during heater operation)Blower motor
(m
3/h)310 (L.H.D.)
300 (R.H.D.)
Electricity consumption
(during heater operation)Blower motor (W) 184
Cooling capacity (kW {kcal/h}) 4.200 {3,612}
Airflow volume (during air
conditioner operation)Blower motor
(m
3/h)460
Electricity consumption
(during air conditioner
operation)Blower motor (W) 225
Magnetic clutch (W) 46 45
Fan type Blower motor Sirocco fan
RefrigerantType R-134a
Regular amount
(approximate quantity)470 {16.6} (L.H.D.)
430 {15.2} (R.H.D.)
(g {oz})
A/C compressorType Vane-rotary
Discharge capacity
120 {120, 4.06}
(ml {cc, fl oz})
Max. allowable speed
6,400
(rpm)
Lube
oilType ATMOS GU10
Sealed volume
(approximate quantity)
120 {120, 4.06} 150 {150, 5.07}
(ml {cc, fl oz})
Magnetic clutch clearance
0.3—0.5 {0.012—0.019}
(mm {in})
CondenserType Multiflow (sub-cooling type)
Radiated heat (kW {kcal/h})4.69 {4,030}: European (L.H.D.) specs.
5.96 {5,130}: European (U.K.), GCC specs.
Receiver/drier
capacity(ml {cc, fl oz}) 190 {190, 6.42}
Desiccant Synthetic zeolite
Expansion valve Type Block type
Evaporator Type Double-tank drawn cup
Page 869 of 909

U–6
CONTROL SYSTEM
WATER HEATER SYSTEMA6E854000169201Outline
•The function, structure and operation of the water heater system is essentially carried over from that of the
current MPV (LW) model, except for following:
—Full/half switching temperature has been changed.
Structural View
.
Operation
Full/half switching
•Depending on the engine coolant temperature, the CPU sets the flame to either full or half strength settings.
.
End Of Sie
CONTROL SYSTEM
1
2
A6E85402002
1 Water heater unit2 Fuel pump (water heater system)
3
1
2
68
{154}74
{165}75
{167}78
{172}˚C
{˚F}
A6E85402003
1 Full mode
2 Half mode3 Idle mode
Page 870 of 909

OUTLINE
U–7
U
SUPPLEMENTAL SERVICE INFORMATIONA6E850201038204•The following additions have been made for the MZR-CD (RF Turbo) since the publication of the Mazda6
Workshop Manual (1730-1*-02C).
A/C unit
•Removal/installation procedure has been modified.
A/C compressor
•Removal/installation procedure has been modified.
Condenser
•Removal/installation procedure has been modified.
Refrigerant lines
•Removal/installation procedure has been modified.
Water heater unit
•Removal/installation procedure has been added.
Fuel pump (water heater system)
•Inspection procedure has been added.
Climate control unit
•Inspection procedure has been modified.
Water heater system
•On-board diagnostic system has been added.
End Of Sie
OUTLINE
Page 871 of 909

U–8
LOCATION INDEX
BASIC SYSTEMA6E850001040201
.
End Of Sie
LOCATION INDEX
8
75
4
3
1
2
6
4
L.H.D.
A6E85002001
8
7
5
43
1
2
6
4
R.H.D.
A6E85002002
1 Blower unit
2 Air filter
3A/C unit
(See U–10 A/C UNIT REMOVAL/INSTALLATION)
4 Rear heat duct
5 A/C compressor
(See U–11 A/C COMPRESSOR REMOVAL/
INSTALLATION)6 Condenser
(See U–12 CONDENSER REMOVAL/
INSTALLATION)
7Heater hose
8 Refrigerant lines
(See U–13 REFRIGERANT LINES REMOVAL/
INSTALLATION)
Page 872 of 909

LOCATION INDEX
U–9
U
CONTROL SYSTEMA6E850001040202
.
End Of Sie
1
2
3
A6E85002003
1 Water heater unit
(See U–15 WATER HEATER UNIT REMOVAL/
INSTALLATION)
2 Fuel pump (water heater system)
(See U–16 FUEL PUMP (WATER HEATER
SYSTEM) INSPECTION)3 Climate control unit
(See U–16 CLIMATE CONTROL UNIT
INSPECTION)
Page 873 of 909

U–10
BASIC SYSTEM
A/C UNIT REMOVAL/INSTALLATIONA6E8516611302011. Disconnect the negative battery cable.
2. Discharge the refrigerant from the system.
3. Drain the engine coolant.
4. Remove the dashboard.
5. Remove the theft-deterrent control module.
Caution
•If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and
abnormal noise will occur. Always immediately plug open fittings after removing any refrigeration
cycle parts to keep moisture or foreign material out of the cycle.
6. Remove in the order indicated in the table. Do not allow compressor oil to spill.
.
BASIC SYSTEM
1
L.H.D.R.H.D.
3
2
R
R
N·m {kgf·cm, in·lbf} 6.86—9.80
{70.0—99.9,
60.8—86.7}
R
R
3
2
1
4
A6E85162001
1 Heater hose
2 Cooler pipe No.4 (L.H.D.) or cooler pipe No.5
(R.H.D.)
(See U–13 REFRIGERANT LINES REMOVAL/
INSTALLATION) (R.H.D.)
(See U–13 REFRIGERANT LINES REMOVAL/
INSTALLATION)3 Cooler pipe No.3
(See U–13 REFRIGERANT LINES REMOVAL/
INSTALLATION) (R.H.D.)
(See U–13 REFRIGERANT LINES REMOVAL/
INSTALLATION)
4A/C unit
(See U–11 A/C Unit Installation Note)
Page 876 of 909

BASIC SYSTEM
U–13
U
REFRIGERANT LINES REMOVAL/INSTALLATIONA6E8516614602011. Remove the battery.
2. Discharge the refrigerant from the system.
3. Remove the washer tank.
4. Remove the air cleaner cover, air cleaner element and air cleaner case. (See F2–36 INTAKE-AIR SYSTEM
REMOVAL/INSTALLATION.)
5. Remove the sedimentor.
6. Remove the No.3 engine mount.
7. Remove the water heater unit.
8. Remove the shroud panel.
9. Remove the right splash shield.
Caution
•If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and
abnormal noise will occur. Always immediately plug all open fittings after removing any
refrigeration cycle parts to keep moisture or foreign material out of the cycle.
10. Remove in the order indicated in the table. Do not allow compressor oil to spill.
11. Install in the reverse order of removal.
Page 878 of 909

BASIC SYSTEM, CONTROL SYSTEM
U–15
U
End Of Sie
WATER HEATER UNIT REMOVAL/INSTALLATIONA6E854000170201
Caution
•If the negative battery cable is disconnected during the purge cycle of the water heater unit, the
gas in the unit may not be properly scavenged, causing white smoke (unburnt gas) to emit from
the exhaust pipe. Before disconnecting the negative battery cable, verify that the water heater unit
is not operating (no blower fan operation noise).
1. Complete the “BEFORE REPAIR PROCEDURE”. (See F2–45 BEFORE REPAIR PROCEDURE.)
2. Disconnect the negative battery cable.
3. Drain the engine coolant.
4. Remove the fuel filter with the pipes still connected, and fix the fuel filter using a rope so that it is out of the way.
5. Remove in the order indicated in the table.
6. Install in the reverse order of removal.
7. Complete the “AFTER REPAIR PROCEDURE”. (See F2–45 AFTER REPAIR PROCEDURE.)
8. Refill the engine coolant.
.
End Of Sie
1 Cooler pipe No.1
2 Cooler pipe No.2
3 Cooler pipe No.3
4 Cooler pipe No.45 Cooler pipe No.5 (R.H.D. only)
6 Cooler hose (HI)
7 Cooler hose (LO)
CONTROL SYSTEM
A
A
B
B
5
4
3
1
2
6
TO
FUEL PIPE
8.9—12.7
{90—130, 79—112}
N·m {kgf·cm, in·lbf}
8.9—12.7
{90—130, 79—112}
A6E85402004
1 Connector
2 Heater hose No.1
3 Heater hose No.34 Water heater unit
5 Fuel pump (water heater system)
6 Exhaust pipe
Page 879 of 909

U–16
CONTROL SYSTEM
FUEL PUMP (WATER HEATER SYSTEM) INSPECTIONA6E8540133502011. Inspect for continuity between fuel pump terminal
A and B using an ohmmeter.
•If not as specified, replace the fuel pump
(water heater system).
End Of Sie
CLIMATE CONTROL UNIT INSPECTIONA6E854061190201Full-auto Air Conditioner
1. Connect the all center panel connectors.
2. Turn the ignition switch to ON position.
3. Measure the voltage at each climate control unit terminal and refer to the terminal voltage list.
•If not as specified, inspect the parts listed under “Action” and the related wiring harness.
—If there is any malfunction, replace the climate control unit.
Terminal Voltage List (Reference)
AME8540W007
Terminal Signal Connected to Test condition Voltage (V) Action
1A Blower motor
feedback signal•Blower motor
•Power MOS
FETFan switch is OFF 12 1. Inspect for continuity or
short circuit (Climate control
unit—blower motor: 1A—B)
(Climate control unit—power
MOS FET: 1A—B, 1C—E)
(Blower motor—blower
relay: A—C) (Blower relay—
fuse: D—BLOWER 40 A
fuse)
2. Inspect for continuity (Power
MOS FET—ground: A—
GND) (Blower relay—
ground: A—GND)
3. Inspect power MOS FET
4. Inspect blower motor
5. Inspect blower relay
6. Inspect BLOWER 40 A fuse
7. Replace power MOS FET Fan switch is at manual
LO7.8
Fan switch is at manual
HI
0.2
2A
1W
2B 2C
2D 2E
2F 2G
2H 2I 2K
2L
* 1A
1B
* *
* *
* 1X1C 1E
1F * 1I
1K
1M 1O
1P 1Q 1S
1T 1U
1J 1L
A6E85402001