fuse RENAULT KANGOO 1997 KC / 1.G Foult Finding - Injection Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 1997, Model line: KANGOO, Model: RENAULT KANGOO 1997 KC / 1.GPages: 363
Page 9 of 363

DPCF01 1.0
LUCAS DIESEL INJECTION
Fault finding - Interpretation of XR25 bargraphs13
AFTER REPAIR
Fiche n° 60 1/2
Bargraph 1 RH extinguished
Code present
1
Use bornier Elé. 1332 for any operations on the computer connector.NOTES
When communication is established, deal with any fault bargraphs which may be
illuminated.
Ensure that the XR25 is not the cause of the fault by trying to communicate with the computer on ano-
ther vehicle. If the XR25 is not the cause of the fault and dialogue is not established with another compu-
ter on the same vehicle, a faulty computer may be causing interference on the K and L fault finding lines.
Disconnect connections successively to determine which computer is at fault.
Check the ISO selector is on position S8, that you are using the latest XR25 cassette and the correct access
code (D34).
Check the battery voltage and carry out any necessary operations to ensure the correct voltage (U battery
> 10.5 volts).
Check the 15 Amp fuses on the engine connection unit have not blown (positions 3 and 4).
Check the connection and condition of the connections on the computer connector and the connection
R67 engine / dashboard.
Check the computer is correctly fed:
- Earth on track 2 of the computer connector (check the condition and tightness of the engine earth
strap and the engine earth MH near to the gearbox housing).
- + after ignition feed on track 1 of the computer connector.
Check the diagnostic socket is correctly fed:
- Earth on track 5.
- + before ignition feed on track 16.
Check and ensure the continuity and insulation of the lines in the connection diagnostic socket/
computer:
- Between track 10 of the computer connector and track 15 of the diagnostic socket.
- Between track 13 of the computer connector and track 7 of the diagnostic socket.
If fault finding is not established after these operations, replace the computer (consult the "Aid" section
for this operation).
13-5
Page 42 of 363

DPCF01 1.0
LUCAS DIESEL INJECTION
Fault finding - Fault charts
13
AFTER REPAIR
Use bornier Elé. 1332 for any operations on the computer connector.NOTES
Chart 1NO DIALOGUE FROM THE COMPUTER TO THE XR25.
Ensure that the XR25 is not the cause of the fault by trying to communicate with the computer on ano-
ther vehicle. If the XR25 is not the cause of the fault and dialogue is not established with another compu-
ter on the same vehicle, a faulty computer may be causing interference on the K and L fault finding lines.
Disconnect connections successively to determine which computer is at fault.
Check the ISO selector is on position S8, that you are using the latest XR25 cassette and the correct access
code (D34).
Check the battery voltage and carry out any necessary operations to ensure the correct voltage (U battery
> 10.5 volts).
Carry out a road test then check using the XR25.
Deal with any illuminated fault bargraphs.
Check the 15 Amp fuses on the engine connection unit have not blown (positions 3 and 4).
Check the connection and condition of the connections on the computer connector and the connection
R67 engine / dashboard.
Check the computer is correctly fed:
- Earth on track 2 of the computer connector (check the condition and tightness of the engine earth
strap and the engine earth on the gearbox housing).
- + after ignition feed on track 1 of the computer connector.
Check the diagnostic socket is correctly fed:
- Earth on track 5.
- + before ignition feed on track 16.
Check and ensure the continuity and insulation of the lines in the connection diagnostic socket/
computer:
- Between track 10 of the computer connector and track 15 of the diagnostic socket.
- Between track 13 of the computer connector and track 7 of the diagnostic socket.
If fault finding is not established after these operations, replace the computer (consult the "Aid" section
for this operation).
13-38
Page 45 of 363

DPCF01 1.0
LUCAS DIESEL INJECTION
Fault finding - Fault charts
13
Carry out a road test then check using the XR25.AFTER REPAIR
If the fault persists, check the fuel supply circuits (for the pump and the injectors).
If necessary, carry out a complete check of the engine (starter drive speed, pump timing, condition of
injectors, rocker arm clearances, compression, .....).NOTES
Chart 4STARTING FAULT (ENGINE WILL NOT START OR IS DIFFICULT TO
START) (warning light extinguished).
Only consult this customer complaint after a complete check using the XR25.
If no fault is shown by the XR25, ensure that the fault is not caused by a faulty immobiliser system.
Check the operation of the preheating system:
Start command mode G10*1* and check for a voltage at the plugs.
If the plugs are not fed, check the connection of the 3 track connector on the relay unit and the condition
of the 70 Amp fuse on the engine connection unit.
13-41
Page 57 of 363

Connect the bornier in place of the computer and check the insulation and continuity of the line:
Computer 2 Earth
Computer 3 Earth
Computer 11 7 Diagnostic socket
Computer 38 15 Diagnostic socket
Computer 24 Fuse F6 15 A
Computer 32 Fuse F3 5 A
Repair.
JF5111.0
INJECTION
Fault finding - Interpretation of XR25 bargraphs17
E7J 780
engine
Erase the computer memory using G0**.
Try to start the engine. Switch the ignition on, then deal with the other faults.
Remember to carry out a status and parameter check.AFTER REPAIR
Bargraph 1 RH side extinguishedFiche n° 27 side 1/2
XR25 CIRCUIT
XR25 aid:No connection, CO, CC-, CC+
1
This bargraph must be illuminated for fault findingNOTES
Test the XR25 on another vehicle.
Check:
- the injection, engine and passenger compartment fuses,
- the connection between the XR25 and the diagnostic socket,
- the position of the ISO selector (S8),
- the conformity of the cassette.
Repair if necessary.
Check:
- the presence of + 12 V on track 16 and earth on track 5 of the diagnostic socket,
- that the XR25 cable is in good condition.
Repair if necessary.
17-9
Page 68 of 363

Check the insulation and continuity of the line:
Computer 52 L5 Fuel pump relay
Repair if necessary.
NOTE : If there is a short circuit on this line, check all the users of this feed.
Check the insulation, continuity and that there is no interference resistance on the line:
Computer 48 L2 Fuel pump relay
Repair if necessary.
JF5111.0
INJECTION
Fault finding - Interpretation of XR25 bargraphs17
E7J 780
engine
Erase the computer memory using G0**.
Try to start the engine. Switch the ignition on, then deal with the other faults.
Remember to carry out a status and parameter check.AFTER REPAIR
Bargraph 8 LH side illuminated or flashingFiche n° 27 side 1/2
FUEL PUMP CIRCUIT
XR25 aid:*08 = ignore this information
CO, CC- or CC+ line 48
CO line 52
8
NOTES
The fault persists! Replace the injection computer.
IMPORTANT: The computer has probably been damaged by an electric shock.
The cause of the damage must be found before fitting a new
computer.
If the fuel pump relay still does not click, replace the fuel pump relay.
If BG 8LH is flashing, erase the computer memory using G0**. Try to start the
engine. If BG 6LH is now permanently illuminated or flashing, deal with this fault. In
certain cases, BG 13RH is illuminated, which must be ignored if ADAC is not present.
Enter the fuel pump relay command mode : G10*.
Does the fuel pump relay click?
The fuel pump
relay does not
clickCheck the presence of 12 volts on track L1 on the fuel pump relay mounting.
If necessary, repair the line to the 15 A fuse.
The fault persists! Replace the injection computer.
IMPORTANT: The computer has probably been damaged by an electric shock.
The cause of the damage must be found before fitting a new
computer.
If the fault persists, replace the fuel pump relay.
The fuel pump
relay clicksCheck the presence of 12 volts on track L3 on the fuel pump relay mounting.
If necessary, repair the line to the 30 A fuse.
17-20
Page 71 of 363

This bargraph only illuminates when the computer feed has been cut (disconnection of the battery, the
computer, ...).
Check the computer feed hygiene:
Computer 24 Fuse 15 A F6
Computer 32 Fuse 5 A F3
Repair if necessary.
Turn the engine.
Switch the ignition off.
Switch the ignition on.
Enter dialogue with the computer.
Erase the computer memory using G0**.
NOTE : memorised faults are erased. It would therefore be useful to carry out a road test to check there
are no faults on the injection system.
JF5111.0
INJECTION
Fault finding - Interpretation of XR25 bargraphs17
E7J 780
engine
Erase the computer memory using G0**.
Try to start the engine. Switch the ignition on, then deal with the other faults.
Remember to carry out a status and parameter check.AFTER REPAIR
Bargraph 13 LH side illuminated or flashingFiche n° 27 side 1/2
MEMORY CIRCUIT
XR25 aid:Loss of computer feed
13
NoneNOTES
17-23
Page 89 of 363

Check the insulation and continuity of the wiring:
Fuel pump relay L5 Impact sensor
Impact sensor C1 Fuel pump
Repair if necessary.
Check the 30A fuel pump fuse.
Check the insulation and continuity of the wiring:
Fuel pump fuse L3 Fuel pump relay
Repair if necessary.
JF5111.0
INJECTION
Fault finding - Status and parameter interpretation17
E7J 780
engine
AFTER REPAIRStart the status and parameter check again from the beginning.
DIAG 6
Fiche n° 27
FUEL PUMP
XR25 aid:The command mode should cause the fuel pump to operate
No fault bargraphs should be illuminated.NOTES
Check the hygiene and presence of earth on track C2 of the fuel pump.
If + 12 V is not reaching the fuel pump, replace the fuel pump relay.
If + 12 V is reaching the fuel pump, replace the fuel pump.
Check the impact sensor is correctly clipped in.
17-41
Page 101 of 363

Check the insulation and continuity of the line:
Relay 5 2 Fan assembly
Fan assembly 1 Earth
Repair.
Connect the bornier in place of the computer and
check the insulation and continuity of the line:
Bornier 14 2 Relay
Repair.
JF5111.0
INJECTION
Fault finding - Status and parameter interpretation17
E7J 780
engine
AFTER REPAIRStart the status and parameter check again from the beginning.
DIAG 17
Fiche n° 27
ANTIPERCOLATION RELAY
XR25 aid:The fan assembly must operate when command mode G17* is used.
No fault bargraphs should be illuminated.NOTES
The antipercolation relay
does not click when its
command mode is used
There is 12 V
on track 1
Ignition on, check for 12 V on track 1 of the fan assembly relay.
There is not 12 V
on track 1Check the line for track 1 of the relay to the fuse.
The antipercolation relay
does click when its
command mode is usedFan assembly relay in place, check, during operation of the command mode,
for 12 V on track 5 of the fan assembly relay.
There is not 12 V
on track 5Check the insulation and continuity of line 3 on the
relay to the fuse.
Repair if necessary.
The fault persists, replace the fan assembly relay.
There is 12 V
on track 5
If the fan assembly still does not operate, replace the
fan assembly.
The fault persists, replace the relay.
The fault persists!
Replace the injection computer.
17-53
Page 128 of 363

Connect the bornier in place of the computer and check the insulation and continuity of the line:
Computer 4 Earth
Computer 16 Earth
Computer 34 Earth
Computer 9 7 Diagnostic socket
Computer 10 15 Diagnostic socket
Computer 18 5 Main relay
Computer 26 2 Main relay
Computer 20 2 Fuel pump relay
Repair if necessary.
JSA051.0
INJECTION
Fault finding - Interpretation of XR25 bargraphs17
D7F 710
engine -
35 tracks
Erase the computer memory using G0**.
Try to start the engine. Switch the ignition on, then deal with the other faults.
Remember to carry out a status and parameter check.AFTER REPAIR
Bargraph 1 RH extinguishedFiche n° 27 side 1/2
XR25 CIRCUIT
XR25 aid:No connection, CO, CC-, CC+
1
This bargraph must be illuminated for fault findingNOTES
Test the XR25 on another vehicle.
Check:
- the injection, engine and passenger compartment fuses,
- the connection between the XR25 and the diagnostic socket,
- the position of the ISO selector (S8),
- the conformity of the cassette.
Repair if necessary.
Check:
- the presence of + 12 V on track 16 and earth on track 5 of the diagnostic socket,
- that the XR25 cable is in good condition.
Repair if necessary.
Check, ignition on, for 12 V on track:
- 1 on the main relay,
- 3 on the main relay,
- 1 on the fuel pump relay.
Repair if necessary.
Ignition on, check for 12 V on track 5 of the main relay:
- If there is 12 V on track 5 of the main relay: replace the fuel pump relay.
- If there is not 12 V on track 5 of the main relay: replace the main relay.
17-83
Page 143 of 363

This bargraph only illuminates when the computer feed has been cut (disconnection of the battery, the
computer, ...).
Check the computer feed hygiene:
Computer 18 5 Main relay
Main relay 3 Fuse
Computer 26 2 Main relay
Main relay 1 Fuse
Computer 20 2 Fuel pump relay
Fuel pump relay 1 Fuse
Repair if necessary.
Turn the engine.
Switch the ignition off and wait for the loss of dialogue between the XR25 and the computer.
Switch the ignition on.
Enter dialogue with the computer.
Erase the computer memory using G0**.
NOTE :memorised faults are erased. It would therefore be useful to carry out a road test to check there
are no faults on the injection system.
JSA051.0
INJECTION
Fault finding - Interpretation of XR25 bargraphs17
D7F 710
engine -
35 tracks
Erase the computer memory using G0**.
Try to start the engine. Switch the ignition on, then deal with the other faults.
Remember to carry out a status and parameter check.AFTER REPAIR
Bargraph 13 LH side illuminatedFiche n° 27 side 1/2
MEMORY CIRCUIT
XR25 aid:Loss of computer feed
13
NoneNOTES
17-98