lock RENAULT SCENIC 2007 J84 / 2.G Automatic Transmission Siemens TA2005 Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2007, Model line: SCENIC, Model: RENAULT SCENIC 2007 J84 / 2.GPages: 139, PDF Size: 0.43 MB
Page 5 of 139

AUTOMATIC TRANSMISSION
Fault finding - Introduction
23A
23A - 5V5 MR-372-J84-23A100$058.mif
SIEMENS TA2005
Vdiag No.: 14-18
4. FAULT FINDING PROCEDURE (continued)
Wiring check
Fault finding problems
Disconnecting the connectors and/or manipulating the wiring harness may temporarily remove the cause of a fault.
Electrical measurements of the voltage, resistance and insulation are generally correct, especially if the fault is not
present when analysing (stored fault).
Visual inspection
Look for damage under the bonnet and in the passenger compartment.
Carefully check the fuses, insulators and wiring harness routing.
Look for signs of oxidation.
Tactile inspection
While manipulating the wiring harness, use the diagnostic tool to note any change in fault status from stored or
present.
Check that the connectors are correctly locked.
Apply light pressure to the connectors.
Twist the wiring harness.
If there is a change in status, try to locate the source of the fault.
Inspection of each component
Disconnect the connectors and check the appearance of the clips and tabs, as well as the crimping (no crimping on
the insulating section).
Check that the clips and tabs are correctly locked in the sockets.
Make sure that no clips or tabs have been dislodged during connection.
Check the clip contact pressure using an appropriate model of tab.
Check the continuity/insulation
Check the continuity of entire lines, then section by section.
Look for a short circuit to earth, to + 12 V or to another wire.
If a fault is detected, repair or replace the wiring harness.
Page 10 of 139

AUTOMATIC TRANSMISSION
Fault finding - System operation
23A
23A - 10V5 MR-372-J84-23A100$116.mif
SIEMENS TA2005
Vdiag No.: 14-18
MODULAR CONNECTOR
Female connection
(connector leading to switch, interface) sensors,
exchanger flow lock-up solenoid valve).Male connection
(connector coming from computer)
AMultifunction switch
BHydraulic electronic interface
COil pressure sensor
DTurbine speed sensor
EExchanger flow lock-up solenoid valve
Page 11 of 139

AUTOMATIC TRANSMISSION
Fault finding - System operation
23A
23A - 11V5 MR-372-J84-23A100$116.mif
SIEMENS TA2005
Vdiag No.: 14-18
COMPUTER INPUTS AND OUTPUTS
INPUTS OUTPUTS
Diagnostic socket
Automatic
transmission
computer
Solenoid valve control
+ battery feed
+ after ignition feed + warning lights display
Intersystem signals + diagnostic
socketIntersystem signal + diagnostic
socket
Driver actions (brake light switch,
gear selector, multifunction
switch)Gear lever lock
AUTO sensors (turbine speed, oil
pressure, oil temperature)Reversing lights
Earth
Wire connection
Multiplex connection
Page 14 of 139

Fault finding - Fault summary table23A
23A - 14V5 MR-372-J84-23A100$290.mif
SIEMENS TA2005
Vdiag No.: 14-18AUTOMATIC TRANSMISSION
Fault finding - Fault summary table
* All Mégane vehicles except ScénicTool faultAssociated
DTCDiagnostic tool title
DF003 0641Analogue sensor power supply
DF005 0840Oil pressure sensor circuit
DF009 0705Multifunction switch prohibited position
DF012 0657Solenoid valve supply
DF016 0795Lock-up solenoid valve circuit
DF017 2753Exchanger flow rate solenoid valve circuit
DF023 0710Gearbox oil temperature sensor circuit
DF029 0709Multifunction switch in unstable position
DF036 0775Pressure modulating solenoid valve circuit
*DF064 0814Display circuit
DF084 C001Multiplex network
DF085 0753EVS1 sequence solenoid valve circuit
DF086 0758EVS2 sequence solenoid valve circuit
DF087 0763EVS3 sequence solenoid valve circuit
DF088 0773EVS5 sequence solenoid valve circuit
DF089 0768EVS4 sequence solenoid valve circuit
DF093 0819Manual sequential controls circuit
DF095 1928Gear lever lock electromagnet circuit
DF105 0741Declutching function when stopping
DF109 D123Engine torque multiplex signal
DF112 2709EVS6 sequence solenoid valve circuit
DF113 0740Converter lockup servo control
DF131 0730Slippage
DF145 D12FInvalid pedal position multiplex signal
MR-372-J84-23A100$290.mif
Page 22 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-22V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF016
PRESENT
OR
STOREDLOCKUP SOLENOID VALVE CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control'.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
(see System operation and Allocation of computer tracks on the modular connector)
●connection code 5BX, between components 119 and 754.
●connection code 5BA, between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 754 between the following connections:
●connection code 5BX,
●connection code 5BA.
If any of the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Replace the solenoid valve or the electric/hydraulic interface wiring harness if the resistance is not 1 Ω ± 0.12
at 23˚C.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF016/DP0TA2005_V18_DF016
Page 38 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-38V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF095
PRESENT
OR
STOREDSELECTOR LEVER LOCK ELECTROMAGNET CIRCUIT
CO: Open circuit
CC.1: Short circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears when the gear lever is in position P.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Check the cleanliness and condition of the gear lever lock electromagnet connections.
With the ignition on, check for + 12 V, on connection AP43 of component 129.
–Disconnect the battery.
–Check fuse 5F in the Protection and Switching Unit, as well as the cleanliness and condition of the connections.
–Disconnect connector PPH2 in the Protection and Switching Unit.
–Check the cleanliness and condition of the connectors.
Use the Universal bornier Elé. 1681. To check the insulation to earth and the continuity of the following
connection:
●connection code AP43, between components 129 and 1337.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
If, with the ignition on, + 12 V is not present on connection AP43 of component 129, run fault finding on the
Protection and Switching Unit.
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Use the universal bornier Elé. 1681. Check the insulation and continuity of the following connection:
●connection code 5DU, between components 119 and 129.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Measure the resistance of component 129 between the following connections:
●connection code 5DU,
●connection code AP43.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
The resistance should be 40 Ω ± 4 Ω at a temperature of approximately 23˚C.
Otherwise replace the gear lever lock electromagnet.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF095/DP0TA2005_V18_DF095
Page 43 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-43V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF113
PRESENT
OR
STOREDCONVERTER LOCK-UP SERVO CONTROL
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
If the following faults are present or stored, deal with them first:
–DF003 Analogue sensor supply.
–DF005 Oil pressure sensor circuit.
–DF016 Lock-up solenoid valve circuit.
–DF177 Automatic transmission overheating.
–DF226 Automatic transmission internal pressure.
–DF244 Turbine speed sensor signal
Use the Mégane II or Scénic II wiring diagram Technical Note.
Check the quality and level of the gearbox oil (see MR 364 Mechanical, 23A, Automatic transmission, Filling - levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Oil change (for Scenic II)).
Check that the gearbox is not leaking oil.
Carry out the converter setting point test.
To locate the cap position, consult MR 364, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Mégane II) and MR 370, Mechanical, 23A, Automatic transmission, Line pressure
measurement (for Scénic II).
Check the oil pressure with the engine switched off using PR003 Oil pressure: if the pressure is greater than
0.2 bars, replace the pressure sensor.
Warm engine with gearbox oil temperature between 65 and 90˚C.
Measure the line pressure under the 3 following conditions:
IMPORTANT
The vehicle must be stationary: handbrake on and brake pedal depressed, no accessories operating
(e.g.: air conditioning)
1engine speed idling:
Shift the gear lever to R, N and D, the pressure reading must be greater than 2.5 bar.
2engine speed at 1200 rpm:
–gear lever in R position, the pressure reading must be greater than 4 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 5.5 bar.
3engine speed at 2200 rpm:
–gear lever in R position, the pressure reading must be greater than 11 bar.
–gear lever in D position, the pressure reading in first gear must be greater than 11 bar.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF113/DP0TA2005_V18_DF113
Page 48 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-48V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF177
PRESENT
OR
STOREDAUTOMATIC TRANSMISSION OVERHEATING
NOTESIf the following faults are present or stored, deal with them first:
–DF003 Analogue sensor supply.
–DF005 Oil pressure sensor circuit.
–DF016 Lock-up solenoid valve circuit.
–DF017 Exchanger flow solenoid valve circuit.
–DF023 Gearbox oil temperature sensor circuit.
–DF036 Pressure modulating solenoid valve circuit.
–DF131 Slipping.
–DF226 Automatic transmission internal pressure.
–DF237 Invalid coolant temperature signal.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Check gearbox oil grade and level.
If an operation is necessary (see MR 364 Mechanical, 23A, Automatic transmission, Filling - levels
(for Mégane II) and MR 370 Mechanical, 23A, Automatic transmission, Oil change (for Scenic II)).
Check that the water-oil exchanger is not blocked.
Measure the resistance of component 754 between the following connections:
●connection code 5BC,
●connection code 5BB.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
The resistance should be between:
2660 Ω < R < 2360 Ω at 20˚C and 327 Ω < R < 290 Ω at 80˚C.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF177/DP0TA2005_V18_DF177
Page 76 of 139

AUTOMATIC TRANSMISSION
Fault finding - Conformity check
23A
23A - 76V5 MR-372-J84-23A100$464.mif
SIEMENS TA2005
Vdiag No.: 14-18
SUB-FUNCTION: GEAR CHANGE (CONTINUED 1)
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
4Gear engagedET013:Gear engagedR for reverse.
1P for 1
st locked.
2P for 2nd locked.
3P for 3rd locked.
4P for 4th locked.
1G for 1st slipping.
2G for 2nd slipping.
3G for 3rd slipping.
4G for 4th slipping.
1 for 1st unlocked.
2 for 2nd unlocked.
3 for 3rd unlocked.
4 for 4th unlocked.In the event of a
fault, refer to the
interpretation of this
status.
5Oil pressurePR003:Oil pressureX < 0.2 barIn the event of a
fault, consult the
interpretation of this
parameter.
6Engine speedPR006:Engine speed0 rpmIn the event of a
fault, consult the
interpretation of this
parameter.
7Standard pedal
positionPR135:Standard pedal
position%In the event of a
fault, consult the
interpretation of this
parameter.
8Raw pedal
positionPR136:Raw pedal
position%In the event of a
fault, consult the
interpretation of this
parameter.
Page 79 of 139

AUTOMATIC TRANSMISSION
Fault finding - Conformity check
23A
23A - 79V5 MR-372-J84-23A100$464.mif
SIEMENS TA2005
Vdiag No.: 14-18
SUB-FUNCTION: PRESSURE CONTROL
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Gear engagedET013:Gear engagedR for reverse.
1P for 1
st locked.
2P for 2nd locked.
3P for 3rd locked.
4P for 4th locked.
1G for 1st slipping.
2G for 2nd slipping.
3G for 3rd slipping.
4G for 4th slipping.
1 for 1st unlocked.
2 for 2nd unlocked.
3 for 3rd unlocked.
4 for 4th unlocked.In the event of a
fault, refer to the
interpretation of this
status.
2Engine speedPR006:Engine speed0 rpmIn the event of a
fault, refer to the
interpretation of
fault DF236 "Invalid
engine speed
multiplex signal".
3Oil pressurePR003:Oil pressureX < 0.2 barIn the event of a
fault, consult the
interpretation of this
parameter.
4Gearbox oil
pressure sensor
voltagePR118:Gearbox oil
pressure sensor
voltageX = 5 VIn the event of a
fault, consult the
interpretation of this
parameter.
5Reference
pressurePR138:Reference
pressure21 bar None.