Page 75 of 128

AUTOMATIC TRANSMISSION
Fault finding – Conformity check23A
23A - 75V4 MR-372-J84-23A050$462.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
SUB-FUNCTION: CREEPING AT IDLE SPEED (CONTINUED)
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(no present or stored faults).
Application conditions: engine stopped, ignition on.
The values indicated in this conformity check are given as examples.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
6Standard pedal
positionPR135:Standard pedal
position% In the event of a
fault, consult the
interpretation of this
parameter.
7Brake pedalET003:Brake light
switch (opening)OPEN, brake pedal
released.
CLOSED, brake pedal
depressed.In the event of a
fault, refer to the
interpretation of this
status.
8Brake pedalET004:Brake light
switch (closure)CLOSED, brake pedal
released.
OPEN, brake pedal
depressed.In the event of a
fault, refer to the
interpretation of this
status.
9Gear engagedET013:Gear engagedR for reverse.
1P for 1
st locked.
2P for 2nd locked.
3P for 3rd locked.
4P for 4th locked.
1G for 1st slipping.
2G for 2nd slipping.
3G for 3rd slipping.
4G for 4th slipping.
1 for 1st unlocked.
2 for 2nd unlocked.
3 for 3rd unlocked.
4 for 4th unlocked.In the event of a
fault, refer to the
interpretation of this
status.
Page 78 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-78V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ET003
BRAKE LIGHT SWITCH (OPENING)
NOTESThere must be no present or stored faults.
The status displays OPEN with the pedal released and changes to CLOSED with the brake pedal depressed.
Check the cleanliness and the condition of the brake light switch connections.
Check the positioning, setting and correct operation of the brake light switch (Pay attention to the floor carpet which
can block the switch).
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference resistance
on the following connection:
●Connection code 5A, between components 119 and 160.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the correct status is not displayed, replace the switch.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2000_V10_ET003/DP0TA2000_V11_ET003/DP0TA2000_V15_ET003
Page 79 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-79V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ET004
STOP LIGHT SWITCH (CLOSURE)
NOTESThere must be no present or stored faults.
The status displays CLOSED with the pedal released and changes to OPEN with the brake pedal depressed.
Check the cleanliness and the condition of the brake light switch connections.
Check the positioning, setting and correct operation of the brake light switch (Pay attention to the floor carpet
which can block the switch).
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference
resistance on the following connection:
●Connection code 5A, between components 119 and 160.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Repair if necessary.
If the correct status is not displayed, replace the switch.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2000_V10_ET004/DP0TA2000_V11_ET004/DP0TA2000_V15_ET004
Page 80 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-80V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ET010
OIL TOO HOT SIGNAL
NOTESThere must be no present or stored faults.
This status means the oil temperature is above the normal operation temperature.
The status displays NO if the gearbox oil temperature is below 140˚C.
The status changes to YES when the gearbox oil temperature rises above 140˚C.
If the correct status is not displayed, use the interpretation of fault DF177 Automatic transmission overheating.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2000_V10_ET010/DP0TA2000_V11_ET010/DP0TA2000_V15_ET010
Page 85 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-85V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ET021
SEQUENCE SOLENOID VALVE 1 CONTROL
NOTESThere must be no present or stored faults.
This status displays ACTIVE when the gear engaged is 3 or 4 and INACTIVE when other gears are engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity between track 10 of the computer connector and track B8 of the modular connector.
Check the continuity of the following connections:
●Connection code 5AV between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
●Connection code 5AV.
●Connection code 5AU.
The value should be 40 ΩΩ Ω Ω
± 2 ΩΩ Ω Ω
at approximately 20˚C.
Repair if necessary.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 ΩΩ Ω Ω
, check the wiring harness, computer connector and modular connector.
Reconnect the computer.
Activate the solenoid valves with command AC024 Actuator sequential control and measure the current
in the solenoid valves.
If the current is 250 mA, the solenoid valve is working properly.
If the current is weaker, check the computer connections and harness up to the solenoid valve.
If the status does not function as specified, use the interpretation of fault DF085 EVS1 Sequence solenoid valve
circuit.
If the fault is still present, replace the electric/hydraulic interface.
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2000_V10_ET021/DP0TA2000_V11_ET021/DP0TA2000_V15_ET021
Page 86 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-86V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ET022
SEQUENCE SOLENOID VALVE 2 CONTROL
NOTESThere must be no present or stored faults.
This status displays ACTIVE when the gear engaged is N or 2 or 3 or 4 and INACTIVE when other gears are
engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity of the following connections:
●Connection code 5AW between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
●Connection code 5AW.
●Connection code 5AU.
The value should be 40 ΩΩ Ω Ω
± 2 ΩΩ Ω Ω
at approximately 20˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 ΩΩ Ω Ω
, check the wiring harness, computer connector and modular connector.
Reconnect the computer.
Activate the solenoid valves with command AC024 Actuator sequential control and measure the current
in the solenoid valves.
If the current is 250 mA, the solenoid valve is working properly.
If the current is weaker, check the computer connections and harness up to the solenoid valve.
If the status does not function as specified, use the interpretation of fault DF086 EVS2 Sequence solenoid valve
circuit.
If the fault is still present, replace the electric/hydraulic interface.
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2000_V10_ET022/DP0TA2000_V11_ET022/DP0TA2000_V15_ET022
Page 87 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-87V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ET023
SEQUENCE SOLENOID VALVE 3 CONTROL
NOTESThere must be no present or stored faults.
This status displays ACTIVE when the gear engaged is P or N or 1 and INACTIVE when other gears are engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity of the following connections:
●Connection code 5AX between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
●Connection code 5AX.
●Connection code 5AU.
The value should be 40 ΩΩ Ω Ω
± 2 ΩΩ Ω Ω
at approximately 20˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 ΩΩ Ω Ω
, check the wiring harness, computer connector and modular connector.
Reconnect the computer.
Activate the solenoid valves with command AC024 Actuator sequential control and measure the current in the
solenoid valves.
If the current is 250 mA, the solenoid valve is working properly.
If the current is weaker, check the computer connections and harness up to the solenoid valve.
If the status does not function as specified, use the interpretation of fault DF087 EVS3 Sequence solenoid valve
circuit.
If the fault is still present, replace the electric/hydraulic interface.
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2000_V10_ET023/DP0TA2000_V11_ET023/DP0TA2000_V15_ET023
Page 88 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-88V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ET024
SEQUENCE SOLENOID VALVE 4 CONTROL
NOTESThere must be no present or stored faults.
This status displays ACTIVE when the gear engaged is 1 or 2 and INACTIVE when other gears are engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity of the following connections:
●Connection code 5AY between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
●Connection code 5AU.
●Connection code 5AY.
The value should be 40 ΩΩ Ω Ω
± 2 ΩΩ Ω Ω
at approximately 20˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 ΩΩ Ω Ω
, check the wiring harness, computer connector and modular connector.
Reconnect the computer.
Activate the solenoid valves with command AC024 Actuator sequential control and measure the current
in the solenoid valves.
If the current is 250 mA, the solenoid valve is working properly.
If the current is weaker, check the computer connections and harness up to the solenoid valve.
If the status does not function as specified, use the interpretation of fault DF089 EVS4 Sequence solenoid valve
circuit.
If the fault is still present, replace the electric/hydraulic interface.
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2000_V10_ET024/DP0TA2000_V11_ET024/DP0TA2000_V15_ET024
Page 89 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-89V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ET025
SEQUENCE SOLENOID VALVE 5 CONTROL
NOTESThere must be no present or stored faults.
This status displays ACTIVE when the gear engaged is 1 and INACTIVE when other gears are engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity of the following connections:
●Connection code 5DL between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
●Connection code 5AU.
●Connection code 5DL.
The value should be 40 ΩΩ Ω Ω
± 2 ΩΩ Ω Ω
at approximately 20˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 Ω, check the wiring harness, computer connector and modular connector.
Reconnect the computer.
Activate the solenoid valves with command AC024 Actuator sequential control and measure the current in the
solenoid valves.
If the current is 250 mA, the solenoid valve is working properly.
If the current is weaker, check the computer connections and harness up to the solenoid valve.
If the status is still not correct, use the interpretation of fault DF088 EVS5 Sequence solenoid valve circuit.
If the fault is still present, replace the electric/hydraulic interface.
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2000_V10_ET025/DP0TA2000_V11_ET025/DP0TA2000_V15_ET025
Page 90 of 128

AUTOMATIC TRANSMISSION
Fault finding – Interpretation of statuses23A
23A-90V4 MR-372-J84-23A050$594.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ET026
SEQUENCE SOLENOID VALVE 6 CONTROL
NOTESThere must be no present or stored faults.
This status displays INACTIVE with any gear engaged.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Check the continuity of the following connections:
●Connection code 5DM between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of component 754 between the following connections:
The value should be 40 ΩΩ Ω Ω
± 2 ΩΩ Ω Ω
at approximately 20˚C.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the resistance is greater than 50 Ω, check the wiring harness, computer connector and modular connector.
Reconnect the computer.
Activate the solenoid valves with command AC024 Actuator sequential control and measure the current
in the solenoid valves.
If the current is 250 mA, the solenoid valve is working properly.
If the current is weaker, check the computer connections and harness up to the solenoid valve.
If the status is still not correct, use the interpretation of fault DF112 EVS6 Sequence solenoid valve circuit.
If the fault is still present, replace the electric/hydraulic interface.
AFTER REPAIRRepeat the conformity check from the start.
Make sure that shifting up and down through each gear works properly.
DP0TA2000_V10_ET026/DP0TA2000_V11_ET026/DP0TA2000_V15_ET026